Prism Module Fiber Laser
Quick Start Guide
redPOWER PRISM OEM
Not to be distributed without prior consent of SPI Lasers UK Ltd.
29/06/2016
Slide: 1
FS-S00149-Rev A

Advertisement

loading
Need help?

Need help?

Do you have a question about the redPOWER and is the answer not in the manual?

Questions and answers

Summary of Contents for SPI Lasers redPOWER

  • Page 1 Prism Module Fiber Laser Quick Start Guide redPOWER PRISM OEM Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 1 FS-S00149-Rev A...
  • Page 2: Table Of Contents

    Customer Requirements Installing Laser Mounting Laser In ... • Electrical Connections to Laser • Start Up/Shutdown Procedure for Prism Laser. • SPI Service Contacts Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 2 FS-S00149-Rev A...
  • Page 3: Customer Requirements Pre Install Water Supply & Fittings

    Customer Requirements Pre Install Water Supply & Fittings Before the redPOWER PRISM OEM laser is delivered to the customer, the customer must ensure that the following Utilities are available. • Water Supply : Cooling Water Requirements • Integrators must ensure that the water condition meets the requirements set out in the following tables and in the manual below.
  • Page 4 Long Module Pressure Drop Short Module Required Chiller Capacity Rated Power 300W 500W 750W 1000W 1500W Units Chiller Capacity 1500 2250 3000 4500 Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 4 FS-S00149-Rev A...
  • Page 5 NALCO and Optishield. NOTE: Additives may reduce the heat capacity of the water. Therefore the flow rate must be increased to compensate. Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 5...
  • Page 6 10mm LLDPE Tubing (Cold Plate) PE-1007-100M-* 6mm LLDPE Tubing (PIPA-Q) PE-0604-0100M-* 10mm Equal Elbow PEM0310W Tube Cutter TSNIP • Essentra End Cap FCWA-0095-013 Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 6 FS-S00149-Rev A...
  • Page 7: Customer Requirements Pre Install Electrical Connections

    Electrical power for the pump diodes must be provided by an external DC power supply. Power for the internal electronics must be provided by a DC auxiliary power supply. SPI Lasers recommends the following DC power supplies for the pump diode supply •...
  • Page 8 Stability Over time and temperature Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 8 FS-S00149-Rev A...
  • Page 9 Buss bars of the PSU and the OEM module. Cable size recommended for the DC power supply to OEM is 10mm Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 9...
  • Page 10: Customer Requirements Pre Install Rs232/485 Communication

    Customer Requirements Pre Install RS232/485 Communication Cable RS232 Communication Cable RS485 Communication Cable Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 10 FS-S00149-Rev A...
  • Page 11 FCMS pins on the user interface connector the Prism Fibre Laser is disabled and the industrial laser machine is put in a safe state. Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016...
  • Page 12: Customer Requirements Pre Install Protective Conductor (Earth)

    Ground. Leaving this open may cause the other signals to float due to insufficient return path to the chassis ground and closing the ground loop. Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 12 FS-S00149-Rev A...
  • Page 13: Customer Requirements Pre Install Unpacking & Handling

    Prism Laser module, SPI advise that the laser must be lifted with two people or by use of a lifting crane. If the laser is required to move over distance a trolley or similar mechanical assistance is required. Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016...
  • Page 14 Confirm all items have been delivered as per the shipping list including items ordered separately. If any damage is found please take photographic evidence for insurance purposes Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016...
  • Page 15 The side of the laser can be mounted to a slide unit • Customer is required to use all 12 mounting holes to support the weight of the unit Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 15...
  • Page 16: Electrical Connections To Laser

    Once all of the above is taken care of go to M8 bolts • start up/Shutdown procedure 9-way D-Type male RS-232 and RS-485 connector 37-way D-type male User Interface connector Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 16 FS-S00149-Rev A...
  • Page 17: Start Up/Shutdown Procedure For Prism Laser

    • Laser is now in a shutdown state. • For operation using Analogue Modulation mode consult SM-S00481 Prism Module Fiber Laser User Instructions Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 17 FS-S00149-Rev A...
  • Page 18: Spi Service Contacts

    Tel: +82 31 926 7580 Tel: +1 408 454 1170 Tel: +86 (0) 21617 19474 Option 2 support@spilasers.com Tim.pier@spilasers.com Dae-Seung.Moon@spilasers.com Michael.Lu@spilasers.com http://www.spilasers.com/our-locations/ Or Contact your Local Distributor/Integrator Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 18 FS-S00149-Rev A...
  • Page 19 Not to be distributed without prior consent of SPI Lasers UK Ltd. 29/06/2016 Slide: 19 FS-S00149-Rev A...