Download Print this page

Outback HUB 10.3 Quick Start Manual

Advertisement

Quick Links

Stacking
Three-Phase Stack
Up to 9 inverters; 1 other device (MATE or MATE3)
Models
Port 1
GTFX (E Series)
Stack Mode Master
GVFX (E Series)
Port 2
Stack Mode 3phase OB Slave A
3phase OB Slave B
3phase OB Slave C
Ports 2 to 10 can be assigned any
3phase OB Slave stack mode;
Jumpers must be in
no more than 3 inverters per mode
"Single-phase" position
or
Three-Phase Stack (Subphase Master)
Up to 9 inverters (ports 1 to 9); 1 other device (port 10); MATE3 only
Ports 1, 4, and 7 are required regardless of the number of slaves; also, the number of slaves should be even
Rev 002.013.000
or higher
st
1
MATE
X
1
2
3
4
5
6
7
8
9
10
or
900-0154-01-00 Rev A.vsd\2013-03-13
©2013 OutBack Power Technologies. All Rights Reserved.
HUB 10.3
X
1
10 9 8 7 6 5 4 3 2
1
MATE
B
Stack Mode Master
Stack Mode Slave
Master A
Slave
Slave
Stack Mode B Phase Master
Stack Mode C Phase Master
A
B
C
Master B
Slave
Slave
Master C
Jumpers must be in
"3-Phase/Split" position
Quick Start Guide
Parts List
HUB10.3
HUB Wiring Cover
#10 x ½" Screws x 2
Cable, CAT5e, 3' (1 m) x 2
Shutter Bushing x 2
Cable, CAT5e, 6' (2 m) x 3
Snap Bushing x 2
Cable, CAT5e, 10' (3 m) x 4
or
st
Dimensions
10.63" (27 cm)
9.24" (23.5 cm)
Single-phase
inverters:
A
Three-phase output
PHASE A
PHASE B
C
PHASE C
Port 1
Port 2
IMPORTANT:
or
OB Slave L1
Not intended for use with
Also ports 3, 5, 6, 8, and 9
life support equipment.
Port 4
or
3p Classic B
Port 7
or
3p Classic C
Single-phase inverters:
Contact Technical Support:
Three-phase output
Telephone:
+1.360.618.4363
Email:
Support@outbackpower.com
Models
Website:
www.outbackpower.com
GS7048E
GFX
OutBack Power, the OutBack Power Logo, and FLEXgrid
GFX (E Series)
are trademarks owned and used by OutBack Power
Technologies, Inc. The ALPHA logo and the phrase
"member of the Alpha Group" are trademarks owned and
used by Alpha Technologies. These trademarks may be
registered in the United States and other countries.
Slave
Slave
900-0154-01-00 Rev A.vsd\2013-03-13
©2013 OutBack Power Technologies. All Rights Reserved.
Mounting
2.
1.
4.23"
(10.7 cm)
1.27" (3.2 cm)
Changing Jumpers
1.
Back of HUB 10.3
6.18"
(15.7 cm)
3.
Used for classic
4a.
series, OutBack
series, and parallel
Single-phase
stacking. This is
(all jumpers)
the factory-installed
initial position.
Used for Subphase
4b.
Master stacking (both
three-phase and series
3-Phase/Split
configurations).
(all jumpers)
NOTE: This option requires MATE3
firmware revision 002.013.000 or higher.
HUB 10.3
3.
1" recommended
2.
3-Phase/Split
Single-Phase
Jumper position
identified by MATE3 on
power-up:

Advertisement

loading

Summary of Contents for Outback HUB 10.3

  • Page 1 Website: www.outbackpower.com identified by MATE3 on GS7048E power-up: OutBack Power, the OutBack Power Logo, and FLEXgrid Used for Subphase GFX (E Series) are trademarks owned and used by OutBack Power Master stacking (both Technologies, Inc. The ALPHA logo and the phrase...
  • Page 2 “Single-phase” position Single-phase inverters: Single-phase Split-phase output inverters: Split-phase output 900-0154-01-00 Rev A.vsd\2013-03-13 900-0154-01-00 Rev A.vsd\2013-03-13 ©2013 OutBack Power Technologies. All Rights Reserved. ©2013 OutBack Power Technologies. All Rights Reserved.