Motor Diagnostic Code - Proheat M80 Service Manual

M series
Hide thumbs Also See for M80:
Table of Contents

Advertisement

(12 Flashes)
3-34
3.1.12

MOTOR Diagnostic Code

Indicates that an over-load fault is detected in precheck or during operation.
Troubleshoot the Motor diagnostic code based on:
1. Motor – mechanical.
2. Motor or PCM – electrical.
Test Procedure – Motor mechanical function:
a) Disconnect all harnesses at the PCM.
b) Disconnect the fuel supply line.
c) Remove blower housing (2) screws and blower housing.
d) By hand, rotate the blower and feel for mechanical binding.
If mechanical interference is felt, isolate the Motor from the Fuel Supply
Pump and Air Compressor by removing the Motor.
replacement, page 3-23.
If the Motor spins freely and there are no obvious mechanical problems,
check the Motor/PCM electrical operation. Go to Test Procedure – PCM
Motor output voltage.
Figure 3-40: Motor Mechanical Check
Test Procedure – PCM Motor output voltage:
a) Disconnect the Motor connector at the PCM.
b) Reconnect the power and switch harnesses at the PCM.
c) Switch the PROHEAT on.
If Motor diagnostic code is still indicated, PCM is faulty.
replacement, page 3-39.
If Motor diagnostic code is no longer indicated, Motor is faulty.
Motor replacement, page 3-23.
TEMP SENSOR 1
BLOWER
POWER
Go to Motor
FUEL INLET
SWITCH INPUT
COOLANT PUMP
Go to PCM
Go to
PROHEAT M-SERIES SERVICE MANUAL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M50M105