13. DCS Receiver
RX ON
RF input : CH center freq : +67.7kHz
Amp : -50dBm
Yes
MODULE1 pin5
>= -65dBm
Yes
MODULE1 pin11
>= -65dBm
Yes
F102 pin2
>= -70dBm
Yes
U100
pin38 >= -70dBm
pin39 >= -70dBm
Yes
U100 pin6, 7, 8, 9
>= 1V
Yes
R123, R125, R127,
R128 >= 1V
Yes
Check U504
END
No
Resolder CON201, C210
No
No
Resolder F102, C106, L110
No
Resolder C107, C108, L109
No
Check & Resolder
RF26MHz, RF PSU Part
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
SGH-E100 Flow Chart of Troubleshooting
Check MODULE1
pin8 = L, pin4 = L
Yes
U100
7-19
No
Check ANT Switch
control circuit
Resoder MODULE1