1 Introduction
This installation manual describes the functioning and
installation of the following control panels:
944.802516 LNG EXT RS_OS Vimar Eikon 3M Z
944.802517 LNG EXT RS_OG Vimar Eikon 3M Z
944.802662 LNG EXT RS_OS Vimar Eikon 3M Z
The control panels have a sensor input for an external
temperature sensor. A fan speed setting and set point can
be set by the end user.
These settings can be read out and set through the
RS485-communication bus (Modbus ASCII protocol).
2 Installation
See the connection diagram for the electrical connections
of the control panel.

3 Operating instructions

The control panel has 4 keys:
FAN MODE
- change fan speed setting.
SET
- view/change temperature set point setting.
DOWN
- decrease selected setting value.
UP
- increase selected setting value.
The leds next to the displays indicate the current fan speed setting.
Description:
LNG EXT RS_OS/OG Vimar Eikon 3M Z
Type:
Installation manual
File:
Do150899 LNG EXT RS_OS-OG Vimar
Eikon 3M Z Installation manual V11
EN.docx
VDH Products BV
LNG EXT RS_OS/OG Vimar Eikon 3M Z
Installation manual
Pages:
By:
944.802516 LNG EXT RS_OS Vimar Eikon 3M Z
944.802517 LNG EXT RS_OG Vimar Eikon 3M Z
944.802662 LNG EXT RS_OS Vimar Eikon 3M Z
6
Doc.nr:
DE
Version:
Date:
150899
1.1
24-05-2015

Advertisement

loading

Summary of Contents for VDH LNG EXT RS_OS Vimar Eikon 3M Z

  • Page 1: Operating Instructions

    LNG EXT RS_OS/OG Vimar Eikon 3M Z Installation manual 1 Introduction 944.802516 LNG EXT RS_OS Vimar Eikon 3M Z This installation manual describes the functioning and installation of the following control panels: 944.802516 LNG EXT RS_OS Vimar Eikon 3M Z 944.802517 LNG EXT RS_OG Vimar Eikon 3M Z...
  • Page 2: Error Codes

    - Temperature maximum alarm (measures temperature above 35 °C / 95 °F). 6 Technical data Type 944.802516 LNG EXT RS_OS Vimar Eikon 3M Z 944.802517 LNG EXT RS_OG Vimar Eikon 3M Z 944.802662 LNG EXT RS_OS Vimar Eikon 3M Z Temperaure range 5..35 °C / 41..95°F...
  • Page 3: Internal Parameters

    LNG EXT RS_OS/RS_OG Vimar Eikon 3M Z Doc.nr.: 150899 Version 1.1 7 Internal parameters To enter the internal parameter mode, keep the DOWN key pressed for more than 10 seconds. Use the UP and DOWN keys to select a parameter number. To show the value of the selected number, press the SET key.
  • Page 4: Network Protocol

    LNG EXT RS_OS/RS_OG Vimar Eikon 3M Z Doc.nr.: 150899 Version 1.1 8 Network protocol The control panel uses the Modbus ASCII-protocol for communication. The message format is: {net number} {function code} {data bytes} {LCR} [CR] [LF] Each byte {} is sent as two hexadecimal ASCII (0..F) characters. LCR is the checksum.
  • Page 5 LNG EXT RS_OS/RS_OG Vimar Eikon 3M Z Doc.nr.: 150899 Version 1.1 Read fan speed setting Request : Response: Exceptions: Byte 0 : FC = 0x03 Byte 0 : FC = 0x03 Byte 0 : FC = 0x83 Byte 1-2: Address (always 1) Byte 1 :Number of bytes (2) Byte 1 : 0x02 (Illegal Byte 3-4: Number (always 1)
  • Page 6: Connection Diagram

    LNG EXT RS_OS/RS_OG Vimar Eikon 3M Z Doc.nr.: 150899 Version 1.1 9 Connection diagram Drawing 150652w1. 10 Contact VDH Products B.V. Tel.: +31 (0)50 – 30 28 900 Productieweg 1 Fax.: +31 (0)50 – 30 28 980 9301 ZS Roden Email: info@vdhproducts.nl...

This manual is also suitable for:

Lng ext rs_og vimar eikon 3m z