ICON 3RU rack frame Contents Introduction Installation Installing the rackframe Door fitting and removal Frame designation Planning the frame module mix Module Installation and removal Inserting and removing power supplies Power supply monitoring Inserting and removing COSMOS controllers Operation Checking the power supply Specification Ordering Information Issue 3...
1050 Introduction The Pro-Bel 1050 rackframe is a 19 inch wide 3U high unit, which can accommodate a wide range of ICON modules. Modules may have either a 20mm or 30mm rear connectors. This helps achieve a balance between the total number of modules and connector space for each module.
Page 3
ICON 3RU rack frame ICON S.D.V. DISTRIBUTION The 1050 3U rackframe with door in place. Technical Manual...
1050 Installation Installing the rackframe Since the 1050 3U rackframe is designed for transverse air flow, it is not necessary to leave vertical space between multiple frames. However, the rear and side vents must not be obstructed. ICON S.D.V. DISTRIBUTION 1050 rackframe air flow K4408 K3408.3...
The label can be created by printing the required text onto a suitable material such as acetate using a laser printer. A Microsoft Word™ template ‘3U Frame Designation Label’ is available on the Pro-Bel web site at www.pro-bel.com in the support/documentation section...
1050 83mm 52mm Text Height TEXT AREA 12mm 50mm The frame designation template Planning the frame module mix The 1050 frame can accommodate up to 17 modules with 20mm rear connectors or up to 12 modules with 30mm rear connectors or a mixture of the two widths. The following table is intended as planning guide when optimising frame occupancy.
ICON 3RU rack frame Module Installation and removal Step 1. Fit the rear connector: ensure plastic latch is fully retracted • slot the rear connector ‘locating guide’ into the appropriate locating holes • then push the latch fully home Latch K3408.3 K3408.3 AN VID...
Page 8
1050 Step 3. Fit the module locator On the 1050 3U frame, the card guides and rear connector fitting holes use 10mm spacing. However modules can only be fitted at 20mm and 30mm spacing, as determined by the chosen rear connectors. To ease the fitting and removal of modules, once 20mm and 30mm rear connectors are installed for each rack’s complement of cards, module locators may be fitted.
ICON 3RU rack frame Inserting and removing power supplies The 1050 3U ICON frame accepts both main and redundant 1950 universal power supplies which autosense input voltage between 90 and 253 volts and 50-60 Hz. The power supply integral fan provides cooling for itself and all modules. There is an 80mm deep space between the front of the modules and the door to allow the cross flow cooling air to reach each module.
Page 10
1050 Warning: When dual power supplies are used, there will be two mains cables. To remove risk of shock remove both cables before servicing. Power supply removal is as follows: remove mains cable • loosen the retaining screw at the rear of unit •...
ICON 3RU rack frame Power supply monitoring The status socket at the rear of the 3U frame allows the status of the 1950 PSU to be monitored remotely. Relay contacts indicate errors in DC output voltage, fan operation or over temperature for each power supply. Relay 1 is fitted on PSU 1 and relay 2 is fitted on PSU 2.
1050 Inserting and removing COSMOS controllers For configuration and status monitoring up to two COSMOS controllers may be slotted into dedicated positions at the rear of the ICON rack frame. COSMOS controller positions K3408.3 AN VID INPUTS CNTL STATUS ANREF 1250 1250 COSMOS I/F...
Page 13
ICON 3RU rack frame Insertion involves the following steps: remove any blanking panels by loosening the two captive screws • carefully align the 1250 COSMOS controller with the internal guides and • gently push it fully home tighten the two captive screws •...
1050 Operation Checking the power supply Power supply indicators are off: check that the mains is connected • check that the fuses are intact • PSU 1950 PSU 1950 STATUS STATUS Power supply indicators ICON S.D.V. DISTRIBUTION Note that the 1950 power LEDs are visible through apertures in the door. In normal operation, they should illuminate green.
Page 15
A replacement unit should still be obtained as soon as possible. Power supply operation is also monitored via the Pro-Bel status monitoring system, please refer to the COSMOS status monitoring manual for details.
Page 16
1050 Pull here to open fuse holder with mains disconnected Active fuse Side view showing fuse holder opened Spare fuse Active and spare fuse located in integral fuse holder Warning: For continued protection against fire, always replace fuse with a 250V 3.15A (T) 20mm fuse as specified.
PSU OK indicator on each unit 9 pin ‘D’ socket on frame for PSU failure alarms 1250 COSMOS controller (main and redundant): The frame has space at the rear for dual status monitoring controllers type 1250 compatible with the Pro-Bel COSMOS system. Technical Manaul...
1050 Ordering Information ICO-FR3U-0000 ICON 3U Rack Frame, no power supplies or COSMOS controllers ICO-FR3U-0100 ICON 3U Rack Frame, no power supply, one COSMOS controller type 1250 ICO-FR3U-0200 ICON 3U Rack Frame, no power supply, two COSMOS controllers type 1250 ICO-FR3U-1000 ICON 3U Rack Frame with one power supply type 1950, no COSMOS controllers...