5.1.5.2. Manual adjustment
(1) Set TV in Adj. mode using POWER ON
(2) Zero Calibrate the probe of Color Analyzer, then place it on
the center of LCD module within 10cm of the surface..
(3) Press ADJ key -> EZ adjust using adj. R/C à 9. White-
Balance then press the cursor to the right (KEY►). When
KEY(►) is pressed 206 Gray internal pattern will be
displayed.
(4) Adjust Cool modes
(i) Fix the one of R/G/B gain to 192 (default data) and
decrease the others.
( If G gain is adjusted over 172 and R and B gain less than
192 , Adjust is O.K.)
(ii) If G gain is less than 172,
Increase G gain by up to 172, and then increase R gain and
G gain same amount of increasing G gain.
(iii) If R gain or B gain is over 255,
Readjust G gain less than 172, Conform to R gain is 255 or
B gain is 255
(5) Adjust two modes (Medium / Warm) Fix the one of R/G/B
gain to 192 (default data) and decrease the others.
(6) Adj. is completed, Exit adjust mode using "EXIT" key on
Remote controller.
▪ If internal pattern is not available, use RF input. In EZ Adj.
menu. 6.White Balance, you can select one of 2 Test-pattern:
ON, OFF. Default is inner (ON). By selecting OFF, you can
adjust using RF signal in 206 Gray pattern.
5.1.6. Reference (White Balance Adj. coordinate and
color temperature)
▪ Luminance: 204 Gray, 80IRE
▪ Standard color coordinate and temperature using CS-1000
(over 26 inch)
Coordinate
Mode
X
Cool
0.271
Medium
0.286
Warm
0.313
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
(1) Normal line (From January to February) LGD
Aging time
X
(Min)
271
1
0-2
286
2
3-5
284
3
6-9
282
4
10-19
279
5
20-35
276
6
36-49
274
7
50-79
273
8
80-119
272
9
Over 120
271
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Temp
△uv
Y
0.270
13,000K
0.0000
0.289
9,300K
0.0000
0.329
6,500K
0.0000
Cool
Medium
Warm
Y
X
Y
X
270
286
289
313
295
301
314
328
290
299
309
326
287
297
306
324
283
294
302
321
278
291
297
318
275
289
294
316
272
288
291
315
271
287
290
314
270
286
289
313
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
(2) Normal line (From March to December) : LGD
Aging time
(Min)
1
0-2
2
3-5
3
6-9
4
10-19
5
20-35
6
36-49
7
50-79
8
80-119
9
Over 120
▪ Standard color coordinate and temperature using CA-210(CH
14)
O/S Module (AUO, INX, Sharp, CSOT, BOE)
x
spec
271
target
278
5.2. Tool Option setting & Inspection per
countries
5.2.1. Overview
(1) Tool option selection is only done for models in Non-USA
North America due to rating
(2) Applied model: LA46H Chassis applied to CANADA and
MEXICO
5.2.2. Country Group selection
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu
(2) Depending on destination, select US, then on the lower
Country option, select US, CA, MX.
Selection is done using +, - KEY
Y
5.2.3. Tool Option inspection
329
▪ Press Adj. key on the Adj. R/C, then select Tool option
354
* Tool option can be reconstructed by Software
349
346
342
337
334
331
330
329
- 13 -
Cool
Medium
X
Y
X
271
270
286
289
282
289
297
308
281
287
296
306
279
284
294
303
277
280
292
299
275
277
290
296
274
274
289
293
273
272
288
291
272
271
287
290
271
270
286
289
cool
med
y
x
y
270
286
289
280
293
299
LGE Internal Use Only
Warm
Y
X
Y
313
329
324
348
323
346
321
343
319
339
317
336
316
333
315
331
314
330
313
329
warm
x
y
313
329
320
339

Advertisement

loading