Calimar CMARSSG20-5 Owner's Manual page 20

Residential chlorine generator
Table of Contents

Advertisement

Unable to increase Chlorine
Production
System Status light solid
Status light is flashing or service
light is on while operating on
low output percentage.
The system will not turn on.
The cell housing is leaking from
the cap (bottom of cell cap or
through the cord hole)
Water is leaking from the cell
plug.
The titanium "legs" that hold up
the cell blades have broken
apart from the blades.
Troubleshooting
continued
Cell is plugged with debris, cold water,
low salt level
Problem with power to Control Center
No AC power to Control Center
System is operating normally
Low salt level, dirty cell, damaged cell
blade coatings.
Incorrect or no voltage coming from the
power source.
Circuit breaker may be tripped
Circuit boards may be damaged.
O-ring may be improperly seated.
Cell cap may be cross threaded.
Water is traveling through a crack in the
cell base and up the cell cord.
The legs have been eaten away due to
corrosive water.
The weld that held the "legs" and blades
together has failed.
20
Check cell and clean, check salt
level, check water temperature.
Check to make sure On/OFF Switch
is on.
Make sure pump is on.
Check Circuit Breaker (Part C on
Illustration, page 13) on bottom of
Control Center; if tripped, press
rubber cover to reset
Verify time clock is providing 220
VAC to Control Center when active
(TO BE DONE BY CERTIFIED POOL
PROFESSIONAL, OR ELECTRICAN)
No solution, everything is fine.
Enjoy your pool!
Set the output to "Boost" and then
hold down the upward arrow
button until the polarity lights begin
to flash back and forth. Check to see
if status light has stopped flashing
or the service light has turned off.
Have an experienced pool
professional or an electrician
confirm that the voltage is existent
and correct.
Check the circuit breaker located on
the control center box and reset the
breaker is it has been tripped.
Call manufacturer to troubleshoot
the system with a technician.
Confirm that O-ring has not been
lubricated. Clean the o-ring slot of
any dirt or debris. Fully seat the o-
ring in into the slot before inserting
the cell back into the housing.
Unscrew cap and confirm that the
cap screws onto the housing
without resistance.
Call manufacturer and troubleshoot
the system with a technician.
Call manufacturer to troubleshoot
the system with a technician.
Call manufacturer to troubleshoot
the system with a technician.