Polyamp PSC80 Installation Manual

Ac/dc power supplies

Advertisement

Quick Links

PSC
C80, P
PSC80, PSC
P
& PSC150
&
Polyamp
mp AB
Box 925
5
191 29
SOLLENTU
UNA
Sweden
n
In
nstalla
ation M
AC
C/DC P
Power
PSC10
00, PS
C100
www.p
olyamp.com
info@p
polyamp.se
Tel: +4
46 85946930
Tel: +4
46 85946930
Manua
al
r supp
lies
SC150
, PSC
PSC24
40 &
PSC15
50 with T3
m
EU
U VAT no SE
DU
UNS no 35-4
00
CA
AGE S4231
05
NC
CAGE S423
Ma
anual-PSC-A
AC.docx
C240
E55610327
76301
430-3372
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSC80 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Polyamp PSC80

  • Page 1 M Manua C/DC P Power r supp lies C80, P PSC10 00, PS SC150 , PSC C240 PSC80, PSC C100 PSC24 40 & & & PSC150 PSC15 50 with T3 Polyamp mp AB www.p olyamp.com U VAT no SE...
  • Page 2 INSTAL LATION M MANUAL PSC seri es AC inpu Warran All P Polyamp D DC/DC co onverters a are warran nted again st defectiv ve materia al and work kmanship. This warr ranty is va alid for 24 4 months f...
  • Page 3: Table Of Contents

    INSTALLATION MANUAL PSC series AC inputs Content   Before installation ......................4   Cable and pin dimensioning ..................4     Input fuse ......................... 4     Inrush current limit ....................4       Installation ........................5     Several output voltages ....................
  • Page 4: Before Installation

    3HE Euro format The power supply type name consists of model mounting. Each pin has a continuous current name PSC80, PSC100, PSC150 and PSC240 rating of 15 A @+55°C and 12 A @+70°C followed by input code and output voltage.
  • Page 5: Installation

    INSTAL LATION M MANUAL PSC seri es AC inpu nstallation in a 3HE 1 19” Euro su ub rack: 1.3 In nrush curr rent limit Check t the pin-out, s see Figure 1 Connec ct the protecti tive earth pin n 32.
  • Page 6: Several Output Voltages

    3 Several output voltages together, separate from input. 3. The converter output is short-circuit proof The PSC series models PSC80, PSC100 and by a constant current limit which works PSC150 can be supplied with one or two unlimited in time. Therefore there is no auxiliary outputs.
  • Page 7: Series Diode With Series Resistor, Option Cr

    INSTAL LATION M MANUAL PSC seri es AC inpu 4.2 Ser ries diode e with serie es resisto option This opt ion is an exte ension of 4.1 1 Series diod When se everal PSC u units are conn nected in parallel w with so calle ed “hot plug i...
  • Page 8: Adjusting Output Voltage When Units Are Paralleled On The Output

    INSTAL LATION M MANUAL PSC seri es AC inpu . To increa ase the outpu ut voltage. Increase th he output vo oltage by turn ning the potentiom meter marked d ”V.ADJ” cl lockwise on the uni it with the low owest output voltage until you r...
  • Page 9: Multiple Loads At The Output

    INSTAL LATION M MANUAL PSC seri es AC inpu 5 Mu ultiple loa ads at th e output x ∆t ) / ∆U C = 1.2 x ( IS If you ar re using seve eral loads, we e recommend fusing th hem separate ely with fast a...
  • Page 10: Output Voltage Sense, Option S

    INSTAL LATION M MANUAL PSC seri es AC inpu .2 OVP o option A 6 Ou tput volt tage sen tion S. An independe nt circuit usi ing a SCR th hyristor is sed as over v voltage prote ection. When The rem mote voltage s sense is used...
  • Page 11: Higher Isolation Voltage, Option E2

    INSTAL LATION M MANUAL PSC seri es AC inpu The alarm m relay can be connected d in two way 1. Norm mally Open ( (NO). Conn nect twisted- -pair (0.25 m -0.5 mm from m centre pin o of the remov vable alarm conn nector and co...
  • Page 12: Insulation Voltage Test

    INSTAL LATION M MANUAL PSC seri es AC inpu 10 Ins sulation v voltage t test Each con nverter has b been isolation n tested in factory b before delive ery. Please no ote that consecut tive insulatio on test damag ge the Y- capacitor rs and affect...
  • Page 13: Dc Isolation Test Input To Output And Input To Case

    INSTAL LATION M MANUAL PSC seri es AC inpu rning! An ins sulation test t shall only b perfor rmed by per rsonnel awa re of the dange ers and haza ards of the te est. 10.3 D DC isolatio on test inp put to utput and...
  • Page 14: Trouble Shooting

    • If the load is too large decrease the SWITCH CRAFT S.A. load or consult your Polyamp dealer. Bel Air 63 5. The unit is broken. Contact your Polyamp CH-2300 La Chaux-de-Fonds dealer. Switzerland The input fuse blows when 11.2...

This manual is also suitable for:

Psc100Psc150Psc240

Table of Contents