The XRS-5 series transducers have an integrated temperature sensor that reports the air temperature at the transducer to the controller. General Guidelines Materials of construction are chosen based on their chemical WARNING: compatibility (or inertness) for general purposes.
(5.0") ANSI, DIN, or JIS 89 mm standards (3.5") Submergence Shield Split Flange (optional) 133 mm (5.2") 155 mm (6. 1 ") nominal ANSI, DIN, or JIS standards 124 mm (4.9") Page EN-4 XRS-5 Series Transducers – OPERATION MANUAL 7ML19985QT81...
Page 6
Submersible transducer, used in Plywood mounting provides excellent isolation, applications where flooding is possible. but must be rigid enough to avoid flexing if subjected to loading. 7ML19985QT81 XRS-5 Series Transducers – OPERATION MANUAL Page EN-5...
Page 7
Do not run cable near high voltage or current runs, contactors or SCR control drives. In all of the following examples the terminal blocks on the transceiver are described in the controller manual. Page EN-6 XRS-5 Series Transducers – OPERATION MANUAL 7ML19985QT81...
HydroRanger 200, DO NOT use coaxial cable. See diagram below for proper procedure. 2-Wire Extension (for EnviroRanger ERS 500, MultiRanger 100/200, and HydroRanger 200 only) drain/shield junction box extend cable using 18 AWG shielded/twisted pair 7ML19985QT81 XRS-5 Series Transducers – OPERATION MANUAL Page EN-7...