Industriefunkuhren _____________________________________________________________ Technical Manual GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface Model 8030HEPTA/GPS ENGLISH Version: 04.00 - 12.04.2018 _____________________________________________________________ IMAGE (8030) FIRMWARE (8024) Valid for Version: 04.xx Version: 04.xx Version: 03.xx...
Page 2
8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 2 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 3
Functionality Disregard may impact function of system/device. Information Notes and Information. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 3 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 4
EU directive - especially with regard to protection of health and safety for the operator and the user - and may be released for sale within the common markets. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 4 / 178...
5.1.4.1 Power Supply Unit Specifications ....................27 5.1.4.2 Fusing ............................27 5.1.4.3 Reverse Voltage Protection ......................27 5.2 Connection GPS Antenna System ................28 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 5 / 178 hopf Elektronik GmbH...
Page 6
8.3.2.3 Network Interface Bonding/Teaming (Activation Key necessary) ..........59 8.3.2.4 Network Interface PRP (Activation Key necessary) ..............64 8.3.2.5 Routing (Activation Key necessary) .................... 67 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 6 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 7
8.3.8.5 Serial Interface (Optional Hardware necessary) ............... 133 9 SSH and Telnet Basic Configuration ............... 149 10 Fault Analysis / Troubleshooting ................150 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 7 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 8
14.5 Accuracy & NTP Basic Principles ................168 15 List of RFCs ....................... 170 16 List of Open Source Packages Used ............... 171 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 8 / 178 hopf Elektronik GmbH Nottebohmstr.
By GPS time synchronization and the worldwide used time protocol NTP (Network Time Pro- tocol) the Time Server 8030HEPTA/GPS turns into a highly accurate NTP Stratum 1 Time Server. It is used for the synchronization of computers and industrial networks.
Page 10
Software supplied: hopf • Management Console) Software 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 10 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 11
• Customizable security banner • NTP local time support 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 11 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
System rear side: The new designed housing concept allows customized system extensions for additional signal outputs (processed ex-works) easily and fast. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 12 / 178 hopf Elektronik GmbH...
WebGUI access. The operation and function of the pushbutton and the display are described in Chapter 7 LCD- Display with Pushbutton – Function. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 13 / 178 hopf Elektronik GmbH Nottebohmstr.
On specific problems the USB connection can be used for a sys- hopf tem recovery after consulting the Support. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 15 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
The MAC address is uniquely assigned for each LAN interface by the company ektronik GmbH. hopf Elektronik GmbH MAC addresses begin with 00:03:C7:xx:xx:xx. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 16 / 178 hopf Elektronik GmbH...
All installed system extensions deviating from the standard system 8030HEPTA/GPS includ- ing the pertinent Status LEDs are documented and described in a device-specific supplemen- tary instruction. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 17 / 178 hopf Elektronik GmbH Nottebohmstr.
This chapter describes the function principle of the Time Server 8030HEPTA/GPS and the internal relations between the different functional groups. Block Diagram 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 18 / 178 hopf Elektronik GmbH Nottebohmstr.
Update of the data in both the display and the WebGUI is subject to specific refreshing cycles. The display indicates if the refreshing cycle is not completed yet. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 19 / 178...
All installed system extensions deviating from the standard system 8030HEPTA/GPS includ- ing the pertinent Status LEDs are documented and described in a device-specific supplemen- tary instruction. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 20 / 178 hopf Elektronik GmbH Nottebohmstr.
This chapter describes the behaviour of the system in special operational phases and condi- tions. Boot Phase The boot process of the Time Server 8030HEPTA/GPS starts after turning on the system or a reset. This phase can be recognized by the LCD-Display and activated LED test of the Status LEDs in the front panel.
The following steps have to be executed in the following sequence: 1. Image Update 8030HEPTA 2. H8 Firmware Update 8030HEPTA 3. H8 Firmware Update 8024GPS 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 22 / 178 hopf Elektronik GmbH...
8. After successful update the board automatically reboots. 9. After approx. 2 minutes the H8 update process is finished and the board is again ac- cessible via WebGUI. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 23 / 178 hopf Elektronik GmbH Nottebohmstr.
LAN interface. The settings for activation keys (e.g. an entered activation key) are neither modified nor influenced by the function FACTORY DEFAULTS. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 24 / 178 hopf Elektronik GmbH Nottebohmstr.
5.1.2 Earthing The Time Server 8030HEPTA/GPS is usually earthed via the PE cable of the power supply. An additional earth cable for surge protection purposes can be connected by means of the earth screw located on the rear side of the System housing.
8030HEPTA/GPS. The corresponding performance data can be taken from the equipment nameplate. The Time Server 8030HEPTA/GPS is currently fitted with a power supply unit with a power consumption of max. 20VA (Standard) or 40VA (47-63Hz). If the internal fuse (device protection) trips it is highly probable that the equipment is faulty.
8030HEPTA/GPS. The corresponding performance data can be taken from the equipment nameplate. The Time Server 8030HEPTA/GPS is currently fitted with a power supply unit with a power consumption of max. 20VA (Standard) or 40VA (47-63Hz). If the internal fuse (device protection) trips it is highly probable that the equipment is faulty.
The coaxial line of the GPS antenna system is placed on the BNC female connector with the "GPS Antenna" inscription on the rear side of the Time Server 8030HEPTA/GPS. More de- tailed descriptions referring to the installation of the antenna system, for example, cable lengths and cable types, are described in the document “Antenna System GPS”.
Using the SEARCH Function of the separate Software (Network Configuration Assistant) in order to access the Time Server 8030HEPTA/GPS and set the basis LAN parameters (e.g. DHCP). Afterwards connect to the WebGUI of the Time Server 8030HEPTA/GPS via Web browser Connect directly with the factory default IPv4-address (ETH0: 192.168.0.1 or ETH1 in...
( F r o n t ) : L E D - T e s t a c t i v e 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 30 / 178 hopf Elektronik GmbH Nottebohmstr.
After connecting the system to the power supply and creating the physical network connection to LAN interface of the Time Server 8030HEPTA/GPS, the device can be searched for on the network via the Software. Then the base LAN parameters (IPv4 address, IPv4 netmask and gateway or DHCP) may be adjusted in order to allow accessibility of the Time Server 8030HEPTA/GPS for other systems on the network.
Page 32
Hardware Address (MAC Address). The factory set MAC address for the Time Server 8030HEPTA/GPS can also be read out via the LCD-Display 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 32 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 33
IP addresses 128.000.xxx.xxx to 191.255.xxx.xxx Each of these networks can consist of up to 65534 devices. Example: 172.001.003.002 (Network 172.001, Host 003.002) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 33 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 34
After entry click on the OK button to confirm. The LAN parameters thus set are directly adopted (without reboot) by the Time Server 8030HEPTA/GPS and are immediately active. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 34 / 178 hopf Elektronik GmbH Nottebohmstr.
If the Sync Source ERROR "RTC error" is enabled after switching on with- out valid time, this can be corrected by releasing a Reset of the Sync Source. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 35 / 178 hopf Elektronik GmbH Nottebohmstr.
INVA Invalid time NTP-Status: The current Stratum and accuracy value of the NTP service is shown here. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 36 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
T u r n O F F / O N p o w e r m a y s o l v e t h e p r o b l e m 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00...
T i m e - Z o n e O f f s e t a n d / o r D S T C h a n g e o v e r n o t i n i t i a l l y s e t b y U S E R 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 39 / 178...
N o t a c t i v e In the above picture a summer-/wintertime changeover is processed on the next hour change. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 41 / 178...
The following detailed explanatory information should be read if anything is unclear while executing the configuration steps. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 43 / 178 hopf Elektronik GmbH Nottebohmstr.
NTERFACE General – Introduction The Time Server 8030HEPTA/GPS should be accessible to a web browser if it has been set up correctly. Enter the IPv4 address <http://xxx.xxx.xxx.xxx> - as set up in the Time Server 8030HEPTA/GPS earlier - or the DNS name on the address line and the following screen should appear.
After successful login, depending on the access level (device or master user), changes can be made to the configuration and saved. Users logged in as “master” have all access rights to the Time Server 8030HEPTA/GPS. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00...
All the links within the tabs on the left hand side lead to corresponding detailed display or setting options. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 46 / 178 hopf Elektronik GmbH Nottebohmstr.
Reload Restoring the saved data Save Fail-save storage of the data in the flash configuration 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 47 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
WebGUI indication can take up to 30 seconds after data transfer to Mod- ule 8024GPS. However, this has no effect on the function of the appropriate set- ting/value. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 48 / 178 hopf Elektronik GmbH...
The error check only verifies semantics and the validity of ranges. It is NOT a logic or network check for entered data. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 49 / 178 hopf Elektronik GmbH Nottebohmstr.
NTP Time Status This area shows basic information about the current time and date of the Time Server 8030HEPTA/GPS. The time always corresponds to UTC. The reason for this is that NTP al- ways works with UTC and not with local time.
Page 51
The display fields LEAP SECOND and STD DST announce a corresponding event to the next hour (insertion of a leap-second or rather switchover of summer/winter time). 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 51 / 178...
The sign '-' must not appear as first or last character of a label. For a correct operation a hostname is required. The field for the hostname must not be left blank. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 52 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 53
If the Ipv6 default gateway is not known, it must be requested by the network administrator. If no standard gateway is available (special case), enter :: in the input field or leave the field blank. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 53 / 178 hopf Elektronik GmbH Nottebohmstr.
Configuration of the Ethernet interface ETH0/ETH1 of the Time Server 8030HEPTA/GPS. ETH1 must not be located in the same sub net as ETH0! 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 54 / 178...
Page 55
If DHCP is not used, the network mask needed to be entered here. Contact your network administrator for details of the used network mask if not known. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 55 / 178...
Page 56
If DHCP is not used, enter the IPv6 address here. If the IPv6 address to be used is unknown, it must be requested by the network administrator. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 56 / 178...
Page 57
VLAN-Tagging. The network application at the other end of the line (e.g. network switch, router etc.) can allocate the data packet to the correct VLAN by checking the marking / tag. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 57 / 178...
Page 58
VLANs. VLAN ID one (1) and two (2) are reserved and are therefore not permitted! 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 58 / 178 hopf Elektronik GmbH Nottebohmstr.
An incorrect configuration can lead to a loss of the network connection so that the Ethernet access to Time Server 8030HEPTA/GPS is going to be refused. In this case settings of Time Server 8030HEPTA/GPS must be set back to de- fault settings! If function Bonding has been activated, parameters for ETH0 and ETH1 cannot be changed any more.
Page 60
A change of the IPv4 address or activating of DHCP do have an immedi- ate effect after confirming the settings – the connection to the web inter- face must be adapted and renewed. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 60 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 61
If the IPv6 address is not known, it must be requested by the network administrator. IPv6 Subnet Prefix Length Input of the IPv6 network length for the " Bonding interface". 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 61 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 62
Time Server 8030HEPTA/GPS are connected also needs to be configured correctly! A wrong configuration can lead to a loss of availability of Time Server 8030HEPTA/GPS! 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 62 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 63
If this asset is configured and the network interface is active, the adjusted network interface is going to be used. Only if the network interface is inactive, mode is changed to the second network interface. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 63 / 178 hopf Elektronik GmbH Nottebohmstr.
PRP network, a so-called RedBox (Redundancy Box) can be used. Time Server 8030HEPTA/GPS supports PRP as DAN and can therefore directly be integrated into a PRP network without using a RedBox. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 64 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 65
A change of the IPv4 address or activation of DHCP will have an immedi- ate effect after applying the settings - the connection to the web interface must be adapted and renewed. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 65 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 66
In that case the settings of Time Server 8030HEPTA/GPS need to be set to "factory default"! The network interface ETH0 of Time Server 8030HEPTA/GPS need to be connected to PRP network "LAN A", network interface ETH1 need to be connected to PRP network "LAN B"! If settings are done without profound knowledge of PRP, severe network prob- lems can occur.
Routes should be used, or routing configuration using a routing file. If IPv6 routes are required, the routes must be made using the settings in Chapter 8.3.2.6 Routing File. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 67 / 178 hopf Elektronik GmbH Nottebohmstr.
For IPv6 routes, the colons of the destination and gateway addresses are not displayed, and the Network Mask column displays the length in hexadecimal 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 68 / 178...
These service settings are valid globally! "Disabled" Services are not exter- nally accessible and are not made externally available by the module! 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 69 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 70
Using SNMP and SNMP- traps the protocol SNMP should be enabled. All fields must be filled in for a correct operation of SNMP. Contact your network administrator for details of data not known. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 70 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 71
Privacy Passphrase: empty empty Right now only one user is supported. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 71 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
• TIME • SINEC H1 time datagram (Activation Key necessary) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 72 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 73
HIGH The setting Minimum Accuracy = LOW may lead to the output of non-syn- chronised (thus possibly wrong) time information. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 73 / 178 hopf Elektronik GmbH...
NTP in SNTP Clients delay times are not evaluated on the network. For this reason the accuracy reached in SNTP Clients is lower than in NTP Cli- ents. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 74 / 178 hopf Elektronik GmbH Nottebohmstr.
In the window "System Info" the current NTP values of the NTP service running on the em- bedded Linux of the Time Server 8030HEPTA/GPS are indicated. In addition to the NTP cal- culated values for root delay, root dispersion, jitter, and stability the stratum value of the Time Server 8030HEPTA/GPS, the status to the leap second, and the current system peer are also found here.
NTP selection algorithm. A list and description of possible characters can be found in the Glossary (see Chapter 14.2 Tally Codes (NTP-specific)). 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 76 / 178...
This option enables or disables Syslog messages which are generated from the NTP service. This value has no effect if Syslog is not configured in the ALARM tab (see Chapter 8.3.5.1 Syslog Configuration). 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 77 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 78
If the Sync Source (here Module 8024GPS) runs in crystal operation (status “crystal“) the NTP service of the Time Server 8030HEPTA/GPS usually behaves in the way that the receipt of time information is stopped from the Sync Source and the stratum value reset to 16 (defined as invalid in NTP).
Page 79
ONFIGURATION NTERFACE 8.3.3.4.4 Broadcast / Broadcast Address This section is used to configure the Time Server 8030HEPTA/GPS as a broadcast or mul- ticast server. The broadcast mode in NTPv3 and NTPv4 is limited to clients on the same sub-network and Ethernets which support broadcast technology.
SINEC H1 TIME DATAGRAM / TIME / DAYTIME sis. Therefore this datagram should be deactivated for security reasons. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 80 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 81
NTP. The synchronisation of a standard NTP-Client with a time basis deviating from UTC results in a wrong time information in the standard NTP- Client and might cause time leaps! 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 81 / 178 hopf Elektronik GmbH Nottebohmstr.
Restarting NTP services is the only possibility of making NTP changes effective without having to restart the entire Time Server 8030HEPTA/GPS. As can be seen from the warning mes- sage, the currently reachable stability and accuracy get lost caused by this restart.
No restrictions are required in this case. Proceed further to Chapter 8.3.3.7.4 Internal Client Protection / Local Network Threat Level 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 83 / 178 hopf Elektronik GmbH...
Page 84
✓ notrap ✓ nopeer 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 84 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 85
The entry of exceptions also works for IPv6 addresses. For this, the IPv6 address must be entered in the column IPv4/IPv6 Address and the length of the IPv6 net mask must be entered in the Netmask column. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 85 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 86
Changes in data do not take effect immediately after clicking on the “Ap- ply” symbol. The NTP service MUST also be restarted (see Chapter 8.3.3.6 Restart NTP). 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 86 / 178 hopf Elektronik GmbH Nottebohmstr.
The keyword key of a client’s ntp.conf determines the key that is used to communicate with the designated server (e.g. the Time Server 8030HEPTA/GPS). The key must be reliable if time is to be synchronised. Authentication causes a delay. This delay is automatically taken into account and adjusted in the current versions.
In order to enable Autokey v2 authentication, the “Autokey Enabled” option must be set to "enabled" and a password specified (may not be blank). 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 88 / 178...
Page 89
This should be carried out regularly as these keys are only valid for one year. If the Time Server 8030HEPTA/GPS is to form part of an NTP trust group, a group key can be defined and uploaded with the "Upload now" button.
If "NIC PRP active" is active, only "PRP0" can be chosen. If "NIC Bonding / Teaming active" and "NIC PRP active" are inactive, "ETH0" or "ETH1" can be chosen. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 90 / 178 hopf Elektronik GmbH Nottebohmstr.
Sending interval = 2 • Value-range: -7 to 6 The sending interval can be chosen between 0.0078125 seconds up to 64 seconds. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 92 / 178 hopf Elektronik GmbH...
This file informs the PTP service, how many seconds UTC and TAI time differs. In case of announcing a leap second by the synchronization source the leap second file will automatically be updated. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 93 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 94
ONFIGURATION NTERFACE If time server 8030HEPTA/GPS is not in operation during the whole announcing time, it is not possible for the application to update its leap second file. The leap second file needs to be updated next time when time server is put in operation.
The NTP service implemented in the system can transmit its own Syslog messages (see Chapter 8.3.3.4.2 NTP Syslog Messages (General / Log NTP Messages to Syslog)). 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 95 / 178...
The SNMP protocol must be enabled in order to use SNMP (see Chapter 8.3.2.7 Management (Management-Protocols – HTTP, SNMP). 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 97 / 178 hopf Elektronik GmbH...
Depending on the messages, their configured levels and notifications levels of the E-mails, a corresponding action is carried out if an event occurs. Modified settings are failsafe stored after Apply and Save only. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 98 / 178 hopf Elektronik GmbH Nottebohmstr.
The user requires this information in the case of service requests, e.g. MACH version, hard- ware status etc. The display "Current DIP Switch Settings" is not applicable for this device. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 99 / 178 hopf Elektronik GmbH Nottebohmstr.
A Factory Default requires a complete check and optionally a new config- uration of the Module 8030HEPTA. In particularly the default MASTER and DEVICE passwords should be reset. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 100 / 178 hopf Elektronik GmbH Nottebohmstr.
Log in is carried out as “Master” user in accordance with the description in Chapter 8.2.1 LOGIN and LOGOUT as User. Press the "Reboot now" button and wait until the restart has been performed. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 101 / 178 hopf Elektronik GmbH Nottebohmstr.
(update takes approx. 1-1.5 minutes) upgrade_8030gen_v0120.img for the embedded image (update takes approx. 2-3 minutes) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 102 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 103
The procedure for the Image update differs only in how the device is restarted. After the image-update the WebGUI displays a window to confirm the restart (reboot) of the device. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 103 / 178 hopf Elektronik GmbH Nottebohmstr.
General-Tab. To delete the "Customized Security Banner" the inserted text must be deleted and saved again. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 104 / 178 hopf Elektronik GmbH...
DEVICE – Device info (serial number 8030…). The settings for activation keys (e.g. an entered activation key) are neither deleted nor restored via the function FACTORY DEFAULTS. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 105 / 178 hopf Elektronik GmbH Nottebohmstr.
(See also Chapter 8.2.1 LOGIN and LOGOUT as User) A new password must contain at least one capital letter and lowercase let- ter, a number, and six characters. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 106 / 178 hopf Elektronik GmbH Nottebohmstr.
5. Perform the download of the file hopf The "private enterprise MIB" is also available via the WebGUI in this area. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 107 / 178 hopf Elektronik GmbH...
Module 8024GPS) with a Module Reset after performing all modifications. This ensures that the Module 8024GPS will be operated with the new and failsafe stored data. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 108 / 178 hopf Elektronik GmbH Nottebohmstr.
• Second Input of the current UTC second (00-59) The input must be complete and according to the stated format. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 110 / 178 hopf Elektronik GmbH...
Minute changeover should be processed 00min ... 59min The data are entered on the basis of the local time. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 112 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Display of the actual GPS receiver values. For analysing the GPS receiver in case of support. This page is updated automatically every 5 seconds. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 113 / 178...
In this mode, a synchronization with a changing position is not possible. Automotive (3D) The automotive (3D) mode allows the use of system 8030HEPTA at mobile locations (except aircraft). 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 114 / 178 hopf Elektronik GmbH...
In this tab the current position is displayed. Longitude / Latitude – Current Position with Longitude and Latitude Display of the actual position calculated by the GPS receiver. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 115 / 178 hopf Elektronik GmbH Nottebohmstr.
The Timer can be set from 2min. to 1440min. Current Timer values In case of an active Timer the appropriate value of the timer is displayed here. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 116 / 178 hopf Elektronik GmbH Nottebohmstr.
This function triggers a hardware reset of (just) the Sync Source (here Module 8024GPS). This function has no effect on the failsafe stored data. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 117 / 178...
Module Errors: Missing data for Time Zone Offset and/or Missing or incomplete data for daylight saving time (DST) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 118 / 178 hopf Elektronik GmbH...
NTERFACE 8.3.7.12 H8 Firmware Update (Sync Source) Patches and Bug Fixes are provided for the Time Server 8030HEPTA/GPS by means of up- dates. The H8 update of the Sync Source is loaded only via the web interface in the Time Server 8030HEPTA/GPS (log in as “master”...
Page 120
A correct image designation is (e.g.): 8024_128_v0400.mot for H8 Firmware (Update takes approx. 1-1.5 minutes) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 120 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
If a collected error message is displayed in the GENERAL tab, there is at least one error (Sync Source Error). This page is updated automatically every 5 seconds. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 121 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 122
Sync Source (here Module 8024GPS) can be synchronized. This happens e.g. after resetting the Sync Source parameters to factory default val- ues. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 122 / 178 hopf Elektronik GmbH Nottebohmstr.
500 msec 8.3.8.1.2 Minimum Sync.-Status for Output Signal output can be configured only to be generated when the Time Server 8030HEPTA/GPS has reached a minimum synchronization status. As soon as this minimum synchronization status drops below this value during operation, the signal output stops unless the TimeOFF Timer has been set greater than 0.
Page 125
If used, the correct settings are described in the additional system manual of the customer- specific device. Otherwise for S1-S8 the DEFAULT-setting (all checkboxes disabled) should not be changed due to compatibility reasons. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 125 / 178 hopf Elektronik GmbH...
Transmission of a 2Hz pulse in the event of a fault allows the connected devices to monitor for line breakage. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 126 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 127
If used, the correct settings are described in the additional system manual of the customer- specific device. Otherwise for S1-S8 the DEFAULT-setting (all checkboxes disabled) should not be changed due to compatibility reasons. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 127 / 178 hopf Elektronik GmbH...
As soon as this minimum synchronization status drops below this value during operation, the signal output stops unless the TimeOFF Timer has been 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 128 / 178...
Page 129
If used, the correct settings are described in the additional system manual of the customer- specific device. Otherwise for S1-S8 the DEFAULT-setting (all checkboxes disabled) should not be changed due to compatibility reasons. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 129 / 178 hopf Elektronik GmbH...
Value > 999 are automatically corrected to 999. • The pulse lengths must be at least 20msec shorter than the pulse in- terval. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 130 / 178 hopf Elektronik GmbH...
Page 131
+ TimeOFF active for the duration of the TimeOFF Timer OUTPUT blocked There is no signal output 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 131 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 132
If used, the correct settings are described in the additional system manual of the customer- specific device. Otherwise for S1-S8 the DEFAULT-setting (all checkboxes disabled) should not be changed due to compatibility reasons. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 132 / 178 hopf Elektronik GmbH...
Page 136
59. second. • local time • 9600 baud, 8 bit, 1 stop bit, no parity 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 136 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 137
+ 02:30h (STX)831234560301969100(LF)(CR)(ETX) 1001 + 11:00h 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 137 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 138
• no announcement of a changeover • The difference time to UTC is +2.30 h 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 138 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
$53 / $55 / $20 "!", "A" or " " (space) $21 / $41 / $20 ETX (end of text) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 141 / 178 hopf Elektronik GmbH...
Page 142
• standard time (winter time) • no announcement of a changeover 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 142 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 143
"!" ($21 announcement of a DST or standard time changeover) CR (carriage return) LF (line feed) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 143 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 144
• It is Thursday 18.07.02 - 02:34:45 o'clock UTC • The clock is synchronous (synchronization status code: SYNC) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 144 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 145
$30-39 CR (carriage return) LF (line feed) ETX (end of text) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 145 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 146
• no announcement of a changeover • ( ) - ASCII-control characters e.g. (STX) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 146 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 147
$30-39 LF (line feed) CR (carriage return) ETX (end of text) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 147 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 148
• no announcement of a changeover • ( ) - ASCII-control characters e.g. (STX) 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 148 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
The navigation through the menu takes place by entering the respective number associated with the menu option (as can be seen in the above image). 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 149 / 178...
• The antenna cable is faulty • The antenna cable is not connected • The antenna is defective • The indirect lightning protection is defective 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 150 / 178 hopf Elektronik GmbH...
Page 151
(e.g. transmitter for pagers) Further information on the subject of the GPS antenna system can be consulted in the manual "Antenna Equipment GPS". 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 151 / 178 hopf Elektronik GmbH Nottebohmstr.
Providing a detailed error description and above listed information avoid the need for additional clarification and leads to a faster processing by the sup- port team. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 152 / 178 hopf Elektronik GmbH Nottebohmstr.
Cleaning agents containing acids • Abrasive media The use of such cleaning agents or media could damage the Time Server 8030HEPTA/GPS. Do not use a wet cloth to clean the Time Server 8030HEPTA/GPS. There is the danger of an electric shock.
Company reserves the right to modify hardware and software at any time. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 158 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
PPS (pulse-per-second) signal ei- ther indirectly via PPS reference clock driver or directly via kernel interface. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 163 / 178 hopf Elektronik GmbH...
Mean Time when required. Leap seconds are defined internationally by the Interna- tional Earth Rotation and Reference Systems Service (IERS). 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 164 / 178 hopf Elektronik GmbH...
NTP can be installed over firewalls and offers a range of security functions. See RFC 5905 for further information. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 166 / 178 hopf Elektronik GmbH Nottebohmstr.
The PTP-devices use either Ethernet or UDP for their network communication. UDP uses the Ports 319 and 320. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 167 / 178 hopf Elektronik GmbH...
3. It goes without saying that the accuracy of the synchronised time cannot be better than the accuracy resolution of the local clock on the NTP server and NTP client. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 168 / 178...
Page 169
The accuracy value in the GENERAL tab of the WebGUI is designed to help the user to esti- mate the accuracy. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 169 / 178 hopf Elektronik GmbH Nottebohmstr.
3.0.28 eeprog 0.7.6 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 171 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 172
You are free to do whatever you please with scanners generated using flex; for them, you are not even bound by the above copyright. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 172 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 173
1.5.2 host-ncurses Copyright (c) 1998-2010,2011 Free Software Foundation, Inc. 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 173 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 174
0.267 i2c-tools 3.1.2 igmpproxy 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 174 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Page 175
(the "Software"), to deal in the Software without restriction, including without limitation the rights to 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 175 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 176
8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 176 / 178 hopf Elektronik GmbH...
Page 177
OF LIABILITY, WHETHER IN CONTRACT, STRICT LIA- BILITY, OR TORT (INCLUDING NEGLIGENCE OR OTH- ERWISE) ARISING IN ANY WAY OUT OF THE USE OF 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 177 / 178 hopf Elektronik GmbH Nottebohmstr.
Page 178
Permissive http://www.gzip.org/zlib/zlib_license.html free soft- ware licence 8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00 178 / 178 hopf Elektronik GmbH Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com...
Need help?
Do you have a question about the 8030HEPTA/GPS and is the answer not in the manual?