Regarding the indicator lamps

Regarding the indicator lamps
When operation of the L A M P, TE M P and PO W E R indicators differs from usual,
check and cope with it according to the following table.
PO W E R
L A M P
i n d i c a t o r
i n d i c a t o r
Lighting
Turned
O r a n g e
o f f
In
Blinking
Turned
In
Green
o f f
Lighting
Turned
In
G r e e n
o f f
Blinking
Turned
Orange
o f f
In
Blinking
(discre-
In
Red
tionary)
Blinking
Red
In
Lighting
or
In
R e d
Lighting
In
R e d
Blinking
Red
In
Blinking
or
Red
In
Lighting
In
R e d
(continued on next page)
9 6
TE M P
i n d i c a t o r
Th e p r o j e c t o r i s i n a s t a n d b y s t a t e .
Turned
o f f
Please refer to the section "Power on/off".
Turned
Th e p r o j e c t o r i s w a r m i n g u p .
o f f
Please wait.
Turned
Th e p r o j e c t o r i s i n a n o n s t a t e .
o f f
Ordinary operations may be performed.
Turned
Th e p r o j e c t o r i s c o o l i n g d o w n .
o f f
Please wait.
Th e p r o j e c t o r i s c o o l i n g d o w n . A c e r t a i n e r r o r
h a s b e e n d e t e c t e d .
(discre-
Please wait until PO W E R indicator finishes blinking,
tionary)
and then perform the proper measure using the item
descriptions below.
Th e l a m p d o e s n o t l i g h t , a n d t h e r e i s a p o s s i b i l i t y
t h a t i n t e r i o r p o r t i o n h a s b e c o m e h e a t e d .
Please turn the power off, and allow the projector to
cool down at least 45 minutes. After the projector has
sufficiently cooled down, please make confirmation of
the following items, and then turn the power on again.
Turned
• Is there blockage of the air passage aperture?
o f f
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
Otherwise, remove the lamp unit once, and then put
back into place, referring to the R e p l a c i n g t h e l a m p .
If the same indication is displayed after the remedy,
please change the lamp referring to the section
R e p l a c i n g t h e l a m p .
The lamp cover has not been properly fixed.
Please turn the power off, and allow the projector to
cool down at least 45 minutes. After the projector has
Turned
sufficiently cooled down, please make confirmation of
o f f
the attachment state of the lamp cover. After performing
any needed maintenance, turn the power on again.
If the same indication is displayed after the remedy,
please contact your dealer or service company.
Troubleshooting
D e s c r i p t i o n