Verify admin-user —-Delete user—Delete all—Please enter the administer
information'( please enter 6 digits PIN, press '#' to conDirm) for 2 times—
remind "Deleting success"(Deleting all of users except loading user)
3. Factory Data Reset Setting
Press 'SET' button from inner body for 5 seconds, release it and a voice navigation of 'Dee'
will be heard. The Factory Reset menu will be displayed, press '#' to conRirm. Once '初始化
成功' is shown, then factory reset is successfully completed. After factory Reset Setting,
Ringerprint, PIN, IC card and other records will be empty; the PIN for ID No.00 admin-user
will be '123450'.
4.low voltage warning
low voltage warning for AA alkaline batteries is (4.8+/—0.2V). There will be a warning
every time when the lock is awakened; there will be also a low voltage notice if emergency
power supply is not enough to support operation.
5.Malicious cracking passwords warning
Keypad will be locked if wrong PIN has been entered for 3 times. During this time, voice
navigation will notify user that keypad has been locked when pressing any key buttons.
Only a correct veriRication from users can be release the locked mode.
6.Emergency power supply
If the power completely ran out and cannot enter inside, users can use a portable charge
and micro usb to provide emergency power supply