Ilockey F1 User Manual

Fingerprint lock

Advertisement

Quick Links

Fingerprint lock user manual
Model: F1
*
Please read this manual carefully before installing
Please keep this handbook in a safe place, to quickly retrieve when needed
*
Ilockey Technology Co.,lTD
Focused on intelligent lock solution

Advertisement

Table of Contents
loading

Summary of Contents for Ilockey F1

  • Page 1 Ilockey Technology Co.,lTD Focused on intelligent lock solution Fingerprint lock user manual Model: F1 Please read this manual carefully before installing Please keep this handbook in a safe place, to quickly retrieve when needed...
  • Page 2: Product Introduction

    Section One Product Fundamental Feature 1,1 Model Outline Drawing 1.2 Product Introduction 1.2.1 Feature • Unlocking mode:Fingerprint, PIN, IC card, mechanical lock and combined...
  • Page 3 • unlocking mode. Different variety of unlocking modes ensure security protection • Instant activation: The use of capacitive sensor and its Auto Wake-up feature enable device to unlock instantly • Smart control: Leading OLED display screen and intelligent voice navigation assist users to correctly operate the device • Master/guest authorization: Admin-user can manage authorization, users permission and unlocking function. Master-user can manage device setting and access basic unlocking function. Guest-user can only access basic unlocking function • Anti-spy system: To prevent spying action, user is allowed to enter any random number(s) before (and/or) after the correct PIN • Battery display: Display of real-time battery life provides warning for user to replace batteries • Double veriDication mode:Unlocking combinations of Fingerprint+PIN or Double Fingerprints create stronger security assurance for user • Deactivation mode: If total incorrect inputs of Ringerprint and PIN have reached 5 times within 5 minutes, system will be automatically deactivated for 3 minutes, preventing from intentional access 1.2.2 Model SpeciDication No. Item Specification Static current <50µA Dynamic current <200mA Battery life ≥8000 times Operating voltage 4.8-6V Battery 4 AA alkaline batteries...
  • Page 4 Intelligent voice navigation and OLED display 10 Control system screen Fingerprint, PIN, IC card 380 (000-009: admin-user) capacity 12 One-time PIN capacity 10 (380-389) 13 Timeframe PIN capacity 10 (390-399) 14 Door-opening history capacity Latest 600 records 15 FAR ≤0.001% 16 FRR ≤0.1% 17 Fingerprint degree...
  • Page 5: System Setting

    2, Choose any combination of unlocking mode to unlock (eg Dingerprint+pin or pin + pin ) → complete veriDication → turn handle and open → door has been unlocked; 3,Open cylinder cover → manually unlock using keys. From Inside:turn handle and open the door → door has been unlocked; Section two Lock operation instruction 2.1 System Setting 2.1.1 Language When the product is Rirst received from the factory provider, there is no Ringerprint, PIN, IC card record/history on the system; the initialized admin PIN is 123450. The default language is Chinese, the Rirst step is change the default setting Chinese into English and then you can follow the OLED manual or the user guide. Navigation Language: Chinese, English the step as below: (Verify admin-user—— System management—System setting—language setting) Note : You can jump into 2.2 the Admin-user Dingerprint or pin set up section for your basic setting directly. 2.1.2 Date & Time Verify administer--- System management—System setting—Time setting...
  • Page 6: Operation Record

    Year-Month-Date and time setting, press ‘#’ to move to next space. 2.1.3 multi-level unlock setting Verify administer--- System management—System setting—Unlock model setting— combination setting—-Single model/Double model Single model means user can only complete 1 veriRication to unlock Double model means user must complete 2 veriRication to unlock(e.g. ‘Ringerprint+PIN’ or ‘PIN+PIN’) 2.1.4 Operation record Verify administer--- System management—information checking—operation record checking operation record can be reviewed according to: order, time or code number. Move upwards to review by pressing key ‘2’ or downwards by key ‘4’. A,According to order:...
  • Page 7 C,According to Code Number 2.2 Admin-user Fingerprint or pin Setup (New user) Voice Navigation will notify on registration success/failure Open the battery box on real panel, press ‘SET’ button from inner body, the initialized admin- user PIN (ie. 123456) of user No.00 will only be kept after factory resetting. Once a new admin-user PIN has been registered, the system will automatically replace and delete the initialized admin-user PIN. User can press ‘*’ to reverse back to previous menu. It can save up to 10 admin-user key (ie. PIN, Ringerprint, IC card)user can register it according to follow step:...
  • Page 8 2.3Admin-user operation manual 2.3.1 Adding user 2.3.1 .1Adding Admin-user Press ‘SET’ button from inner body, system remind you to verify the Admin-user information, setting menu will be shown once veriRication has been completed. The screen will then display main menu with voice navigation, choose corresponding menu numbers Verify admin-user —-Add user—Add administration User—Please enter the administer information’( please enter 6 digits PIN, press ‘#’ to conDirm) for 2 times— remind “Operation success” 2.3.1.2 Adding normal user Verify admin-user —-Add user—Add normal User—Please enter the administer information’( please enter 6 digits PIN, press ‘#’ to conDirm) for 2 times— remind “Operation success” 2.3.1.3 Adding timeframe user...
  • Page 9 Verify admin-user —-Add user—Add normal User—Please enter the administer information’( please enter 6 digits PIN, press ‘#’ to conDirm) for 2 times— remind “Operation success” 2.3.1.4 Adding One-time user Verify admin-user —-Add user—Add one-time User—Please enter the administer information’( please enter 6 digits PIN, press ‘#’ to conDirm) for 2 times— 2.3.2 Deleting user 2.3.2.1 Deleting user code. Verify admin-user —-Delete user—Delete User code—Please enter the administer information’( please enter 6 digits PIN, press ‘#’ to conDirm) for 2 times— remind “Deleting success” 2.3.2.2 Deleting user type. Verify admin-user —-Delete user—Delete User type—Please enter the administer information’( please enter 6 digits PIN, press ‘#’ to conDirm) for 2 times— remind “Deleting success” 2.3.2.2 Deleting all...
  • Page 10: Emergency Power Supply

    Verify admin-user —-Delete user—Delete all—Please enter the administer information’( please enter 6 digits PIN, press ‘#’ to conDirm) for 2 times— remind “Deleting success”(Deleting all of users except loading user) 3. Factory Data Reset Setting Press ‘SET’ button from inner body for 5 seconds, release it and a voice navigation of ‘Dee’ will be heard. The Factory Reset menu will be displayed, press ‘#’ to conRirm. Once ‘初始化 成功’ is shown, then factory reset is successfully completed. After factory Reset Setting, Ringerprint, PIN, IC card and other records will be empty; the PIN for ID No.00 admin-user will be ‘123450’. 4.low voltage warning low voltage warning for AA alkaline batteries is (4.8+/—0.2V). There will be a warning every time when the lock is awakened; there will be also a low voltage notice if emergency power supply is not enough to support operation. 5.Malicious cracking passwords warning Keypad will be locked if wrong PIN has been entered for 3 times. During this time, voice navigation will notify user that keypad has been locked when pressing any key buttons. Only a correct veriRication from users can be release the locked mode. 6.Emergency power supply If the power completely ran out and cannot enter inside, users can use a portable charge and micro usb to provide emergency power supply...
  • Page 11 Ilockey Technology Co.,lTD Add: 6th Floor Shuipan building, No 3193 Binghe Avenue , Futian District, Shenzhen Tel:+86-755-84046958 Fax:+86-755-84046959 Email: info@ilockey.com www.ilockey.com...