Interface BSC8D Operating Instructions Manual

Interface BSC8D Operating Instructions Manual

8 channel measuring amplifier
Hide thumbs Also See for BSC8D:

Advertisement

Quick Links

8 channel measuring amplifier BSC8D
BSC8D SubD15 (front side)
BSC16D (rear side)
Version: 11.09.2013
Operating Instructions
15-208 Revision A
BSC8D M12 (front side)
BSC8D 6A (front side)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BSC8D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Interface BSC8D

  • Page 1 8 channel measuring amplifier BSC8D Operating Instructions 15-208 Revision A BSC8D SubD15 (front side) BSC8D M12 (front side) BSC16D (rear side) BSC8D 6A (front side) Version: 11.09.2013...
  • Page 2: Table Of Contents

    Activating the bridge completion for strain gauge quarter bridges ..........8 Accessories............................9 Technical data ............................9 Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 ● Fax 480.948.1924 ● Email: ● ORDER TOLL-FREE 800.947.5598 www.interfaceforce.com...
  • Page 3: Description

    Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 ● Fax 480.948.1924 ● Email: ● ORDER TOLL-FREE 800.947.5598 www.interfaceforce.com...
  • Page 4: Terminal Assignment

    GND supply voltage blue Tare black Table 3: Connection for voltage supply, M8 plug connector Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 ● Fax 480.948.1924 ● Email: ● ORDER TOLL-FREE 800.947.5598 www.interfaceforce.com contact@interfaceforce.com...
  • Page 5: Wiring Diagram For Quarter Bridges And Half Bridges

    5-pin round connector 5-pin round connector 5-pin Sub-D socket 5-pin Sub-D socket Pin assignment for 37-pin Sub-D Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 ● Fax 480.948.1924 ● Email: ● ORDER TOLL-FREE 800.947.5598 www.interfaceforce.com contact@interfaceforce.com...
  • Page 6: Assignment For Bsc8S Without Usb Port (Slave Unit)

    Output ±5V AI 5 Input assigned CH7 - Channel Output ±5V AI 6 Input assigned Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 ● Fax 480.948.1924 ● Email: ● ORDER TOLL-FREE 800.947.5598 www.interfaceforce.com contact@interfaceforce.com...
  • Page 7: Assignment For Bsc16D With Usb Port

    Channel 8 Output ±5V AI 7 Input assigned 20-27 Ground Analog ground AI GND Analog ground Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 ● Fax 480.948.1924 ● Email: ● ORDER TOLL-FREE 800.947.5598 www.interfaceforce.com contact@interfaceforce.com...
  • Page 8: Activating The Bridge Completion For Strain Gauge Quarter Bridges

    1% to 2%. Optionally, the measuring amplifier is supplied with 120 ohm or 1000 ohm bridge completion. Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 ● Fax 480.948.1924 ● Email: ●...
  • Page 9: Accessories

    4ms high level (3.5V ... 30V) Supply Supply voltage 11...28 V DC Power consumption 24V (12V) DC Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 ● Fax 480.948.1924 ● Email: ● ORDER TOLL-FREE 800.947.5598 www.interfaceforce.com contact@interfaceforce.com...
  • Page 10 They constitute neither warranty of characteristics in the sense of § 459, Paragraph 2, of the German Civil Code nor grounds for liability. Copyright  1999-2013 Made in Germany ME-Meßsysteme GmbH Interface Inc. ● 7401 East Butherus Drive, Scottsdale, Arizona 85260 USA ● Phone 480.948.5555 ● Fax 480.948.1924 ● Email: ● ORDER TOLL-FREE 800.947.5598 www.interfaceforce.com contact@interfaceforce.com...

Table of Contents