Maintenance; Troubleshooting; Replacement Parts - AquaScape 96030 Instruction And Maintenance Manual

Automatic dosing system
Table of Contents

Advertisement

Available languages

Available languages

Maintenance

The Aquascape Automatic Dosing System requires minimal
maintenance. When replacing water treatments, take a few
seconds to inspect and clean the tubing of any debris that
has formed or become trapped in the tubing. A soft pipe
cleaner, available at most hobby stores, can be used to
clean the tubing.
The pump cartridge, located on the underside of the control
panel, is a consumable part that may wear over time,
reducing the accuracy of the system. It is recommended to
replace the pump cartridge once each year (Pump Cartridge
Kit Item# 96040). Please see replacement parts for more
information.
Do not operate at temperatures below 40°F / 4°C as doing
so will void the warranty.
Your Aquascape Automatic Dosing System and
liquid water treatments are not designed to be
operated during freezing temperatures. The unit
is equipped with an internal protection thermostat
that will shut off the dosing pump at temperatures below
40°F / 4°C. Remove the dosing system during winter
freezing temperatures and store it in a frost free location.

Replacement Parts

Automatic Dosing System Replacement Parts
No.
Item number/description
1.
96043 - Output Hose Holder
2.
96044 - O-Ring
3.
96047 - Mounting Plate
4.
96040 - Pump Cartridge Kit
5.
98375 - 6-Watt Transformer
6.
96041 - Tubing Kit
96054 - Control Panel Kit
7.
(includes control panel, inner
tubing and discharge tubing).
8.
96045 - Canister
www.aquascapeinc.com |
2
8
CAN 1-866-766-3426 |
US 1-866-877-6637

Troubleshooting

• The pump does not seem to be pumping the liquid
treatment from the pouch into my pond or fountain.
– Make sure the unit is getting power.
– Make sure the inner tubing and discharge tubing are
properly connected and not kinked.
– Make sure the system is primed. To enter the priming
mode, hold the x2 dosing button for 3 seconds (this
may take several minutes). Refer to page 5 for more
information.
– Listen closely, as you should be able to hear the pump
turning if it's working correctly.
– If problems persist, it may be time to replace the
pump cartridge.
• There is no power reaching the unit.
– Check that the transformer is plugged in.
– Try replacing the transformer; please note that the
Aquascape Automatic Dosing System uses a 12V low
voltage outdoor rated transformer.
Parts List