Wiring Diagram - Ruud PowerVent AP14236 Use And Care Manual

Gas residential water heater residential 40, 50, 60 gallon
Table of Contents

Advertisement

CONNECTION DIAGRAM
INDUCER
6 PIN CONNECTOR
BK
FV
IGNITER AND
BK
FLAME PROBE
W
GAS
BK
VALVE
BK
W
ELECTRONIC
CONTROL
W
Y
R
BL
R
CAUTION! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING!
18
Wiring
If local codes permit, the water heater may
be connected to electric service with the
power cord provided (DO NOT use an
extension cord). A grounding receptacle is
required.
If local codes do not permit the use of
cord connections, a 120 V, 50/60 Hz
power supply, with suitable disconnecting
means, must be connected to the black and
white leads in the heater control enclosure.
A knock-out hole is provided to permit use
of conduit or metal-clad cable connectors.
ON / OFF
SWITCH
BL
W
G
PRESSURE
SWITCH
TEMPERATURE
SWITCH
G
G
W
R
R Y
BL
SIZE: 6.5" X 5.5"
COLOR: BLACK
APPROVED BY:
The maximum current draw is
approximately 5.0 amps.
The water heater must be electrically
grounded in accordance with local
codes, or, in the absence of local codes,
in accordance with latest edition of the
National Electric Code ANSI/NFPA No.
70. Refer to the figures below for water
heater internal wiring.
NOTE: It is not recommended that this
unit be installed on a GFCI circuit.
ELECTRONIC
CONTROL
TEMPERATURE
PRESSURE
SWITCH
"H" "N"
BK = BLACK
BL = BLUE
G = GREEN
R = RED
W = WHITE
Y = YELLOW
SCHEMATIC
FLAME
SENSOR
IGNITER
FV SENSOR
L2
I
G
L1
ON / OFF
SWITCH
SWITCH
AX4761