ZIP HydroTap G4
®
User Guide
Affix model number label
here
802006UK
802006UK BCS Residential User Guide - Aug 2015- V2.01
Page 1 of 28

Advertisement

Table of Contents
loading

Summary of Contents for Zip Heater HydroTap G4

  • Page 1 ZIP HydroTap G4 ® User Guide Affix model number label here 802006UK 802006UK BCS Residential User Guide - Aug 2015- V2.01 Page 1 of 28...
  • Page 2: Table Of Contents

    Table of contents ap safety ..........Page 3 • T • Tap operation ........... Pages 4 to 9 • Safety sensor calibration ......Page 10 • Tap lights ..........Page 10 to 11 • LCD screen & menu ......... Pages 12 to 25 •...
  • Page 3: Tap Safety

    Tap safety Classic and Elite models The safety lock feature is provided to prevent boiling water flowing if the red BOILING control is inadvertently activated. This function can be activated and deactivated from either the tap or from the touch screen display (located on the Command-Centre To activate the safety lock (from the tap)
  • Page 4: Tap Operation

    Tap operation To dispense boiling water (with the safety lock off) Classic Depressing the red BOILING lever allows the dispensing of boiling water. Pulling forward the red BOILING lever allows the tap to operate in a “no-touch” mode. Water will flow from between 5 and 15 seconds (this is user adjustable, see page 25).
  • Page 5 Tap operation To dispense chilled water Classic Depressing the blue CHILLED lever allows the dispensing of chilled water. Pulling forward the blue CHILLED lever allows the tap to operate in a “no- touch” mode. Water will flow from between 5 and 15 seconds (this is user adjustable, see page 25).
  • Page 6 Tap operation Arc / Cube functionality On powerup, wait 30secs. for the unit to calibrate before selecting either the red illuminated boiling with safety, or blue illuminated chilled water or white illuminated chilled sparkling water mode, by touching the select button. The Arc / Cube control may be rotated in a...
  • Page 7 Tap operation To dispense sparkling water Operate both levers together Classic Depressing both the red BOILING and the blue CHILLED levers allows the dispensing of sparkling water. Pulling forward both levers allows the tap to operate in a “no- touch” mode. Water will flow from between 5 and 15 seconds (this is user adjustable see page 25).
  • Page 8 Tap operation Classic mixer tap Lifting the lever up will Increase flow Cold increase the flow rate Decrease flow and lowering the lever will decrease the flow rate. Lower the lever all the way down to close the tap. When the lever is moved in the direction of the blue dot, the temperature is decreased and when moved...
  • Page 9 Tap operation All-in-One tap The top of the All-in-One tap is operated in the same manner as a Classic HydroTap G4. The two levers ® are used for dispensing boiling, chilled and chilled sparkling water. The safety lock operating in the same manner as the Classic HydroTap ®...
  • Page 10: Safety Sensor Calibration

    Safety sensor calibration Light intensity varies from site to site, therefore it is recommended that a recalibration be performed at the time of the installation. All direct sunlight must be shaded from the HydroTap G4, during the ® calibration. This can be achieved by closing any nearby curtains, blinds, etc. Procedure Pull both levers forward •...
  • Page 11: Tap Lights

    Tap lights Warning light all models Filter light Red warning light Flashing warning light When the indicator light flashes fast and continuous, a system fault has occurred. Check for details on the faults screen. If unable to rectify, call a qualified service agent.
  • Page 12 LCD screen Zip HydroTap G4 features a ‘TOUCH’ screen for easy setup and operation ® adjustment. (See page 28 for home menu icons). Other possible messages in status window Status** Information Notes Safety OFF Product is in normal operation mode Safety ON Safety lock is activated Refer to section...
  • Page 13: Lcd Screen Menu

    LCD screen menu Main Sub menu Sub menu Section menu options Language English / Deutsch • Product info. • Module Revision Serial number Information Product number Calibration • Filters log • Filters • System faults • Faults found • Filter flush •...
  • Page 14 LCD screen operation - section A A. Set language • Press the [MENU] button for main menu. • Press the [Language] button. • Select the language. • Press [<=] button for the previous menu. LCD Screen operation - section B B.
  • Page 15 LCD screen operation - section C C. Installation Once your Zip HydroTap G4 unit has been installed, Go to the install menu to ® configure the system settings for your product. Sub menu 1. - Filter flush. 2. - Filter reset. 3.
  • Page 16 LCD screen operation - section C 2. Filter reset After replacing the filter, the counters should be reset. • Press the [MENU] button for main menu. • Press the [Install] button. • Press the [Filter Reset] button. • In the next screen, press [YES] button if you want to flush the filter.
  • Page 17 LCD screen operation - section C 5. CO purge When fitting a new gas cylinder, it is important to purge the gas lines as follows. • Press the [MENU] button for main menu. • Press the [Install] button. • Press the [Purge CO] button. •...
  • Page 18 LCD screen operation - section D D. Service Caution must be observed when changing any settings within the service menu as any changes may affect the normal operation of the unit. This can only be done by a Zip technician. Please contact your Zip service provider for further assistance.
  • Page 19 LCD screen operation - section E E. Security The Zip HydroTap G4 allows the appliance coordinator to set up a password ® to protect against users changing the preferred system settings. To set a password • Press the [MENU] button for main menu.
  • Page 20 LCD screen operation - section G nstructions G. Settings • Press the [MENU] button for main menu. • Press the [Settings] button. • Then enter your 4-digit password. You will need to enter your password to access the settings screens. If you have forgotten the password see page 19, LCD screen operation - section E security.
  • Page 21 LCD screen operation - section G ions Filter Zip HydroTap G4 allows the user to adjust filter life and edit filter usage. ® Note The filter life may be set as a function of litres used, or in months from the filter change. When the first of these functions is reached (i.e.
  • Page 22 LCD Screen operation - Section G Energy modes This mode allows the HydroTap G4 to go into energy saving mode. There ® are two options available: sleep mode and on/off mode. In sleep mode the unit will go to “Sleep” after a 2hr period of inactivity. The boiling water will gradually drop to either 68°C or room temp, as shown in the table below and the chilled water will be ON or OFF.
  • Page 23 LCD Screen operation - Section G Note Any attempt, during off mode, to dispense water, will bring the unit out of sleep mode. The unit will return to sleep mode after 2 hours of non use. Please allow sufficient time for the water to reach the set temperature after disabling the sleep mode.
  • Page 24 LCD Screen operation - section G Safety To allow the safety setting to be changed using the touch screen (Classic and Elite) • Press the [MENU] button for main menu. • Press the [Setting] button. • Press the [Safety] button. •...
  • Page 25: Filter Maintenance

    LCD Screen operation - section G Dispense times The ability to change the maximum dispensing time for both the hot and cold water has been introduced. The default settings for the maximum dispensing times is 15 seconds. The operator may change both the hot and cold dispensing times from 5 to 15 seconds, in increments of 1 second.
  • Page 26 Filter maintenance • Caution. A small amount of water will drip as the cartridge is removed. • Do not tilt the cartridge as water may spill from it if tilted. • Unpack replacement cartridge and remove sanitary cap, write today’s date where shown on the label.
  • Page 27: Changing The Co 2 Cylinder

    Changing the CO cylinder • Turn the CO cylinder regulator off (anti-clockwise). The knob will screw up and away from the bottle. • Remove the cylinder from the cupboard and disconnect the regulator. If the braided hose is removed from the regulator, be careful not to lose the small plastic sealing olive, located inside the end of the hose.
  • Page 28: Home Menu Icons

    Home menu icons Home menu icon Safety switch is enabled. The HydroTap G4 will not dispense any boiling water. ® See page 3 for safety lock operation. Safety switch is disabled. Boiling water may be dispensed. See page 4 for tap operation details. Sleep mode is active.