Summary of Contents for Bongshin BS-8300

  • Page 3 Thank you very much for your purchasing BONGSHIN Digital Weighing Indicator of BS-8300. This Instruction Manual will lead you to use BS-8300 with top reliability, High speed, high accuracy. BS-8300 is Digital Weighing Indicator amplifying the analog output from a...
  • Page 4 Please keep the following using conditions certainly ■ EARTH To avoid an electric error such as a noises in your production line It should be earthed before installation certainly. Specially it will be safety to divide the power of Indicator into a load cell. ■...
  • Page 5 - A compact Appearance by DIN regulations ( DIN 193 x 96 Panel system ) - Easy to preset, change, confirm the weight value by the numeral key. - Improved a convenience and precision of operating with Message Function. - Can use or disuse each key function. (SETUP Reference) - Weight Memory function even in electro spark case.
  • Page 6 DC 10V ±5%, 300㎃ up to 8 x 350ohm load cells 0.3 μV/D Within 0.01% F.S. -1㎷ ~ +34㎷ Max. 34㎷ Min. 5㎷ Zero drift : ±0.2 μV/℃ RTI max. Span drift : 20ppm/℃ max. ±0.3 μV p.p or less 10 ㏁...
  • Page 7 ± AC 110/220V 10%, 50/60Hz 30 VA 10 year -10℃~+40℃ (+14℉ ~ +104℉ ) 85% Rh Max. 193(W) x 162(D) x 96(H) 2.5 kg – Serial Interface : RS-232C – Serial Interface : RS-422 – Parallel Interface : BCD INPUT...
  • Page 9 : : It will lamp when 1step(90%) control works : : It will lamp when 2step(100%) control works : ON when the weighing is run. : ON when the weight is stable. : ON when the current weight is 0 kg. : ON when the tare weight is stored.
  • Page 10 * The Key operating can be permitted or prohibited by SETUP-F10 * When pushing the key, it sounds "OK". * Each Key works either a single function or compound functions. A compound function key will be a command key when it push first and According to the command key, the fixed value works its function, The key to finish a input data is ENTER Key.
  • Page 11 TARE Key 1. Set-up of TARE Key ① Put a TARE on the weighing plate ② TARE Key → SET Key 2. Remove of TARE Key ① Remove TARE on the weighing plate ② Push TARE Key and push ENTER Key. SP 2 Key : Set Point 2(100%) weight.
  • Page 12: Enter Key

    ENTER Key This have 2way to use as follows . 1) When canceling it with input the setting value 2) Change the set Point 2 value Increases the first place value to 1.
  • Page 13 ■ : Power ON, OFF switch It will be safe to use it after 10minuate for a precise measurements. ■ : Available to change AC110/220V with multiple. Before setting up, please confirm the power voltage. Please change the connect terminal of 110V/220V after opening the cover If you need to change.
  • Page 14 EXC+ SIG+ SIG- EXC+ (Red) SIG+ (Green) SIG- (Blue) EXC- (White) EXC- SHIELD The wire color of load cell according to a manufactures. EXC+ EXC- SIG+ SIG- SHIELD CAS, TMI, AND WHITE GREEN BLUE SHIELD GREEN BLACK WHITE YELLOW INTERFACE BLACK GREEN WHITE...
  • Page 15 : COM1, PAUSE, STOP, START, ZERO, PRINT This key is to control a equipment from the outside . Please connect between COM terminal and each input terminal . Because the power of input terminal was connected with 12V voltage From the inside. * An electric current is about 10mA.
  • Page 16 ☞ GENEANL RULES - Avoid sudden Collision, vibration, temperature, water, wind - Use a stable power supply 110V/220V ± 10% 50/60Hz Set up voltage 220V (Adjust the power voltage because the choice terminal of power is inside.) - Connect and power off the switch when connecting the external equipments.
  • Page 17 ▣ What is Calibration? Calibration is to adjust max weight, minimum division, decimal point displayed to Indicator To the actual weight worked by load cell. ☞ It should calibrated certainly when load cell or indicator will be changed. ▣ what is span adjustment. Span adjustment is to make the display value from "0"...
  • Page 18 1 Step : Minimum Division Set 2 Step : Maximum Capacity Set 3 Step : Setting Weight in span calibration 4 Step : Zero Calibration 5 Step : Span Calibration 6 Step : END - Function : Range → 1~ 100 A step to set up a division value.
  • Page 19 - Function : Range → 1 ~ 99,999kg A step to set up max. weight. The display will appear "CAP."(Capacity) and discretion number "C1000.0." (max. 5figure) It can input the maximum weight as the end-user demands instead of discretion number. How to input is to push ENTER key after inputting discretion number.
  • Page 20 or over 10% of full capacity. ( In case of less 1/5,000 resolution ,the value of standard weight must be over 10% of full capacity at least.) ( In case of over 1/5,000 resolution ,the value of standard weight must be over 20% of full capacity at least.) (Notice) If span capacity is set less 10% , indicator will display error message.
  • Page 21 ☞ REF 1. If zero calibration is done without any error, “good” message is displayed and program moves into Step 5 automatically. ☞ REF 2. If the “ZERO” key is pressed, only zero calibration is completed and program moves SAVE & EXIT mode. please push ESC key.
  • Page 22 - Function : The "END" message is displayed in 6 step, all span adjustment is end. Press ENTER key after put down of span standard weight on the platform. The indicator will enter into user's weighing mode. Display Description Step 6 “ENTER”...
  • Page 23 ▣ What is Simulation Calibration? Calibration is performed for matching the BS-8300 to a strain-gage sensor. The following two type of calibration are available for the BS- 8300. ▣ Equivalent input Calibration. Calibration is performed without an actual load by entering the rated output value (mV/V) and the capacity (to be indicated) of the strain- gage sensor by the keys.
  • Page 24 1 Step : Minimum Division Set 2 Step : Maximum Capacity Set 3 Step : Rated Output value Set 4 Step : Zero Calibration 5 Step : END - Function : Range → 1~ 100 A step to set up a division value. "d"...
  • Page 25 - Function : Range → 1 ~ 99,999kg A step to set up max. weight. The display will appear discretion number "C1000.0." (max. 5figure) It can input the maximum weight as the end-user demands instead of discretion number. How to input is to push ENTER key after inputting discretion number. ♣...
  • Page 26 Hysteresis, input resistance, output resistance and zero balance. Enter the capacity and the rated output value required for equivalent input calibration into the BS-8300. - Function : A step to check the zero conditions of Indicator. After appearing "UnLoAd", please push ENTER key.
  • Page 27 - Function : The "END" message is displayed in 5 step, all span adjustment is end. Press ENTER key after put down of span standard weight on the platform. The indicator will enter into user's weighing mode. Display Description Step 5 “ENTER”...
  • Page 28 -- The meaning of " SET-UP " : is to choose each proper functions for matching the indicator with the appliances of field. * How to enter into set-up mode This set-up mode is required for proper weighing operation when indicator connect with other appliance. You can enter into sep-up mode by below two methods.
  • Page 29 Press "CLR" key after input any function number by numeric key. Indicator will display function number directly from present function number. (EXAMPLE) * Present display : F01-01 Press CLR key --> "F02-00" display --> Press CLR key. --> "F03-01 display --> Continuously press CLR key --> "F04-XX"...
  • Page 30 “ ”...
  • Page 31 No decimal point 0.00 0.000 0.0000 1 : Less vibration Adjust value according to the condition 9 : Much vibration how many times converted digital value read display. None automatic zero 0.5 sec .5 digit Auto-zero tracking will per 1 automatically bring 2.0 sec...
  • Page 32 No motion Detection Condition 03 : Less vibration If weight change within given time is not bigger 99 : Much vibration than the SET range, stable condition is displayed.. 00 : Start, stop Relay ON 03 : 0.3 sec Relay ON 99 : 9.9 sec Relay ON 0.3sec/per 1count 03 :...
  • Page 33 Packer Mode Discharging Mode 600 bps (bit per second) 1200 bps 2400 bps 4800 bps 9600 bps No data output Stream mode Transmit only in stable condition Print key mode Transmit when data is required → Request signal : device ID(F13 : Device ID) →...
  • Page 34 01 : Device ID “1” It is used the no. of indicator when system is 99 : Device ID “99” connected. gram kilogram Sequence print Piece print Normal print Sub-total Print Grand-total Print Through Setting EMPTY Range. Through Setting FULL Range.
  • Page 35 Display Meaning 0 2 . 0 5 . 1 8 MAY. 5th, 2002 Display Meaning 1 3 . 3 0 . 0 0 01 : 30 : 30 PM...
  • Page 36 Receive Data ○ Signal Ground 1 ○ ○ Request to Send ○ Clear to Send 9 pin port(Male) RS-232C port of ○ Data Set Ready BS-8300 ○ Carrier Detect ○ 20 Data Terminal Ready 25 pin port(Female) serial port of computer...
  • Page 37 Receive Data 1 ○ ○ Chassis Ground ○ Carrier Detect 9 pin port(Male) ○ Data Terminal Ready RS-232C port of BS-8300 ○ Data Set Ready ○ Request to Send ○ Clear to Send 9 pin port(Female) serial port of computer ■...
  • Page 38 ■ C Program #include <bios.h> #include <conio.h> #define COM1 #define DATA_READY 0×100 #define TRUE #define FALSE #define SETTINGS 0×E3 int main(void) int in, out, status, DONE = FALSE; bioscom(0, SETTINGS, COM1); cprintf(“…BIOSCOM [ESC] to exit …₩n”); while (!DONE) status = bioscom(3, 0, COM1); if (status &...
  • Page 39 ○ 16,17 Wire Connect RS-422 port of BS-8300 25 pin serial port of computer Parallel BCD input is used to change the PART to the external device. This device make it effective to weigh a various works changing the PART with a connection of Computer, PLC, Digital Switch.
  • Page 40 ▣ 9P D-Type Female Connector PIN NO SIGNAL 1×10 2×10 4×10 8×10 1×10 2×10 4×10 ▣ BCD INPUT CIRCUIT...
  • Page 41 PRINT SHEET (SEQUENCE) PRINT SHEET (PIECE) ============ ============ DATE : 2003/11/22 DATE : 2003/11/22 TIME 12:35:07 TIME 12:35:07 CODE CODE SN D WEIGHT SN D WEIGHT 49.98 kg 49.98 kg 60.00 kg ============ 50.30 kg DATE : 2003/11/22 52.10 kg TIME 14:50:10 49.00 kg...
  • Page 42 Packer Mode Discharging Mode F09-0 : Sequence 2 step Control 1(Packer Mode) F09-1 : Output 2step,Input 1step Control * Sequence 2step Control The signal of 1Step,2Step will be ON. Also if the set-up weight was the same or greater, the signal will be OFF * Output 2step,Input 1step Control Control Mode for the output only was made with 1step to...
  • Page 43 Sequence 2step Control ( Packer Mode ) Finished Signal & F09-0 High, Low Signal ▣ The basic operating is simple 2step control But, High and Low Signal output a signal and have a finished signal ▣ 1,2 Step Control according to the weight was changed. Each weight was setting weight and greater then, it’s signal is ON, the except o f it is OFF ▣...
  • Page 44 Sequence 2step Control ( Discharging Mode ) Finished Signal & F09-1 High, Low Signal ▣ The basic operating is simple 2step control But, High and Low Signal output a signal and have a finished signal ▣ 1,2 Step Control according to the weight was changed. Each weight was setting weight and greater then, it’s signal is ON, the except o f it is OFF ▣...
  • Page 45 ERROR CAUSE Reference. Checking for Input, Input resistance Load cell damage Output of load cell. : about 420Ω Insulation Resistance Value. Output resistance Waving a weight resistance : about 350Ω Value. badness of load cell. Checking Insulation Insulation Weighing part error Resistance value of Resistance Load cell.