Smoke Exit On The Top; Chimney Connector; Fitting Of The Handle; Assembly Of Flue Spigot And Blanking Plates Pre-Utilisation Check - Camargue 134 10 15 Technical Manual

En 13240, output: 10 kw
Table of Contents

Advertisement

Camargue - ref. 134 10 15

2.6. Smoke exit on the top

Figure 5
-
Remove the supplement of flue baffle.
-
Lift the cast iron top from the stove.
-
Remove the blanking plate and the clamp.
-
Fit the sealing rope in the groove and attach the flue
spigot and the supplementary baffle A using the three
bolts and washers supplied.
-
Remove the internal baffle and the rear heat shield.
-
Position the sealing rope in the groove on the rear
aperture of the stove and fit the blanking plate and the
clamp.
-
Replace the internal baffle, the supplement of flue
baffle and the cast iron top.

2.7. Chimney connector

The connection to flue must be carried out
according to local building regulations.
-
The appliance must be installed as close as possible
to the chimney.
-
The connector pipe must be approved for installation
with combustion products (either 24 ga. Black painted
or blued steel or 316 grade 20 ga. Stainless steel or 1
mm vitreous enamelled steel).
-
Pipe diameter must not be less than the appliance
spigot diameter. If there is no other solution, the
reduction can not be more than one diameter lower
than the flue spigot and be situated as distant as
possible from the flue connection of the appliance.
-
The connection can be either vertical or horizontal. For
horizontal connections, avoid right angle bends.
-
The join between the connection pipe and the
stovepipe, and the flue, must be leak tight.
-
The connection pipe and any draught stabiliser must
have access for cleaning.
-
The spigot should be connected to a minimum of 125
mm flue system and in that case the appliance is
capable of burning untreated wood and recommended
solid fuels.

2.8. Fitting of the handle

In order to avoid the damaging of the threading, first put
the handle in operating position then screw it into the
taping of the lock (fig. 6).
2.9. Pre-utilisation check
Check the condition of the filler seals, that the door
closes correctly , that the window is not damaged, that
the smoke passages are not obstructed by pieces of
packaging or removable parts. All removable parts, fuel
retainer, oscillating grate, baffle, must be correctly
installed.
Note : if it acts of a ceramics braid, it is consumable and
thus brought to be changed by the user.
6
A : Blanking
C : Clamp
plate
D :
Sealing rope
B :
Flue collar
Figure 5 - Smoke exit on the top
Figure 6 - Fitting the handle

2.10. Maintenance of the Chimney

Very important : In order to avoid any incident
(chimney fire, etc...), maintenance tasks must be
carried out regularly. If the appliance is regularly used,
the chimney should be swept several times per year,
together with the stovepipe connection section.
If the chimney catches fire, you must cut off the flue
draught, close the doors and windows, hatches and
keys, remove the embers from the stove, stop up
the connection hole with wet cloths and call the Fire
Brigade.
DO NOT OPEN THE DOOR OF THE APPLIANCE
(OR AIR INLET) UNDER ANY CIRCUMSTANCES
Chimney condition should be checked at least once per
year by a professional engineer.
Installation instructions
E : Supp of flue
baffle
Technical manual "1141"