Using the Locator:
After the Locator has successfully completed the Self Test
the Locator is ready for use as per normal.
It will not undertake another Self Test that day.
If the Locator has failed the Self Test the Warning symbol
will appear in the bottom right hand corner of the screen.

Automatic Daily Self Test

If the error code 'OVER' is displayed alongside the Warning
symbol this indicates that there is a significant external signal
present that has corrupted the actual Self Test process.
The source could be an active Signal Generator, Transmitter,
Sonde or Locator or a nearby transformer or other power
source emitting a strong Power mode signal.
In this situation make sure all nearby Signal Generators,
Transmitters and Sondes are switched off or move
a few metres / feet to a different location. The Locator will
automatically initiate a new Self Test when it is next switched
on and will continue to do this until a successful Self Test
has been achieved.
If the Locator still fails a Self Test then this is indicating
that there is a fault and the Locator should be withdrawn
from service. Contact C.Scope or a C.Scope Authorised
Service Centre for advice.