Vicon V1305R-DC Installation & Operation Manual

Variable-speed receivers

Advertisement

Quick Links

X992
MODEL V1305R-DC
VARIABLE-SPEED RECEIVERS
Copyright © 2002 Vicon Industries Inc. All rights reserved.
Product specifications subject to change without notice.
Vicon and its logo are registered trademarks of Vicon Industries Inc.
VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788
TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266)
UK: 44/(0) 1489-566300 INFOFAX: 800-287-1207 WEB: www.vicon-cctv.com
Vicon part number 8006-8992-02-02
Rev 202 Section 9 & 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V1305R-DC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vicon V1305R-DC

  • Page 1 Copyright © 2002 Vicon Industries Inc. All rights reserved. Product specifications subject to change without notice. Vicon and its logo are registered trademarks of Vicon Industries Inc. VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116 24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 INFOFAX: 800-287-1207 WEB: www.vicon-cctv.com...
  • Page 5: Fcc Notice

    FCC Notice Note: Complies with Federal Communications Commission Rules & Regulations Part 15, Subpart B for a Class A digital device. WARNING This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instruction, may cause interference to radio and television reception.
  • Page 7 Caution: Careful selection of the proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended are installed. In all cases, coaxial cable impedance should be 75 ohms.
  • Page 9: Table Of Contents

    Preset Connections .......................... 17 Video Input and Control from Transmitter Connections................18 Video In and Video Out Connections....................18 Control Settings..........................18 Option 1 Setting ..........................20 Option 2 Setting ..........................20 Contents • • i X992 Rev 202 V1305R-DC...
  • Page 10 Electronic Limit Stops Setting......................21 Test Mode Setting ..........................21 Clear All Presets ........................... 22 Autoiris Setting..........................22 Finishing Installation ......................... 22 Operation............................23 Maintenance ............................23 Fuse Replacement..........................23 Shipping Instructions........................24 Technical Information ........................25 ii • • Contents X992 Rev 202 V1305R-DC...
  • Page 11: Important Safeguards

    Use only with a mounting accessory recommended by Vicon, or sold with the video product. Any mounting of the video product should follow Vicon’s instructions, and a mounting accessory recommended by Vicon should be used.
  • Page 12 Vicon or that have the contact with them might be fatal. same characteristics as the o riginal part. Unauthorized substitutions may result in fire, electric shock, or other 16.
  • Page 13: Introduction

    In latching mode, the relay must be reset to remove the condition. The V1305R-DC is encased in a metal weatherproof enclosure. A 25 W heater option is available as an option, Model V1305R-H. Seven compression fittings are provided for routing cable.
  • Page 14 Notes 2 • • Introduction X992 Rev 202 V1305R-DC...
  • Page 15: Installation

    Make sure the unit is properly grounded via the earth ground of the power cable. Cover Removal To open the cover of the V1305R-DC, remove the four (4) screws from the top of the unit. When the cover is removed, it remains attached to the enclosure by a cord.
  • Page 16: Auxiliary Functions

    When mounting the heater assembly, be sure to orient it so that the end with the brown and red wires is closest to the power terminal block mounted in the receiver adjacent to the main PCB. The heater is wired to the power terminal block. 4 • • Installation X992 Rev 202 V1305R-DC...
  • Page 17: Wiring The Unit

    Seven cable entry fittings are provided for routing of cables. All cables should be routed through cable entry fittings and terminated at the appropriate terminal block. Use the closest entry fittings to the terminal block so that congestion is minimized inside the unit. Refer to Figure 2. Installation • • 5 X992 Rev 202 V1305R-DC...
  • Page 18: Power Cable

    The V1305R-DC requires a maximum of 50 W. Choose the appropriate cable gauge for the total power requirement. Vicon strongly recommends the use of line conditioners, voltage regulators, and uninterruptible power supply (UPS) systems.
  • Page 19: Control Signal Cabling

    Maximum Operating Distance Cable Type Maximum Distance Belden 9406* 5000 (1500) Belden 9402* 5000 (1500) Belden 8723* 8000 (2400) Belden 8162* 15,000 (4600) Belden 9729* 15,000 (4600) Belden 9182 25,000 (7600) *Dual cable Installation • • 7 X992 Rev 202 V1305R-DC...
  • Page 20: Simplex Operation

    Table 5 Duplex Operation Number of Cables to be Connected Cable Type Star Daisy-Chain Belden 9406 Belden 9402 Belden 8723 Belden 8162 Belden 9729 Belden 9182 Figure 3 Daisy-Chain and Star Configurations 8 • • Installation X992 Rev 202 V1305R-DC...
  • Page 21: Vicoax Ii Control System (With V1422)

    Caution: Take care to install only one cable per fitting or water could enter the enclosure and damage the receiver. Note: Be sure to route wires away from the heater, if installed. Installation • • 9 X992 Rev 202 V1305R-DC...
  • Page 22: Receiver Power Connections

    10 inches (25 cm) from the end of the cable. 4. Insert the end of the power cable through the cable entry fitting and thread the nut onto the fitting. Tighten the sealing nut firmly and secure the cable. 10 • • Installation X992 Rev 202 V1305R-DC...
  • Page 23: Pan-And-Tilt, Lens And Auxiliary Connections

    Note: The receiver has two other Grounds on the TB5 connector that achieve the same solution. They are Ground (pin 2) and Lens Common (Ground) (pin 9), but these should be reserved for lens control if an electronic lens is used. Installation • • 11 X992 Rev 202 V1305R-DC...
  • Page 24 8. Tighten the screws on the terminal blocks to secure the wires and secure the cables with the cable ties provided. Figure 6 Grounding Diagram 12 • • Installation X992 Rev 202 V1305R-DC...
  • Page 25 Signal Name Connector TB1 Pin Aux 1 (NO) Aux 1 Common Aux 2 (NO) Aux 2 Common Auxiliary Connector TB2 Pin Aux Relay Coil Supply Aux 4 Relay Drive Aux 3 Relay Drive Installation • • 13 X992 Rev 202 V1305R-DC...
  • Page 26: Alarm Input/Tamper Connections

    10 inches (25 cm) from the end of the cable(s). 4. Insert the end of the cable(s) through the cable entry fitting and thread the nut onto the fitting. Tighten the sealing nut firmly and secure the cable(s). 14 • • Installation X992 Rev 202 V1305R-DC...
  • Page 27: Daisy-Chain Configuration

    7. Wire the conductors to the appropriate screw terminals on screw terminal TB1 on the Communications Module. Refer to Figure 4 and Table 11. 8. Tighten the screws on the terminal blocks to secure the wires and secure the cables with the cable ties provided. Installation • • 15 X992 Rev 202 V1305R-DC...
  • Page 28: End-Of-Line Termination

    3. Slip the sealing nut over the cable with the threads facing toward the end of the cable. Position the sealing nut approximately 10 inches (25 cm) from the end of the cable. 16 • • Installation X992 Rev 202 V1305R-DC...
  • Page 29: Video In Connections

    3. Slip the sealing nut over the cable with the threads facing toward the end of the cable. Position the sealing nut approximately 10 inches (25 cm) from the end of the cable. Installation • • 17 X992 Rev 202 V1305R-DC...
  • Page 30: Video Input And Control From Transmitter Connections

    1 and 255, provided that no other receiver on the data line is given the same address. The V1305R-DC2 in all circumstances should only be addressed as 1. When the MODE switches are set to 1 or 2, configuration options can be set. 18 • • Installation X992 Rev 202 V1305R-DC...
  • Page 31 241 X 157 X 243 X 159 X 245 X 161 X 247 X 163 X 249 X 165 X 251 X 167 X 253 X 169 X 255 X 171 X Installation • • 19 X992 Rev 202 V1305R-DC...
  • Page 32: Option 1 Setting

    Option 1 setting requires MODE switch pole 1 to be ON and pole 2 to be OFF. The OPTION switch can then be set. The V1305R-DC is factory set with pole 8 OFF for the standard and preset ViStar25. If a continuous rotation model, VIST25-VRP, is being used, pole 8 should be set to ON.
  • Page 33: Electronic Limit Stops Setting

    With the exception of autoiris, the above operations are active only while the push button is being pressed. After performing the test mode, be sure to reset the OPTION switch to the receiver address and both MODE switches to OFF. Installation • • 21 X992 Rev 202 V1305R-DC...
  • Page 34: Clear All Presets

    When installation is complete, close the cover the receiver. Be sure that the grounding strap is properly connected at either end and that the rubber seal is in place. Secure the cover with the with the four (4) screws. 22 • • Installation X992 Rev 202 V1305R-DC...
  • Page 35: Operation

    The V1305R-DC has a fuse located in the power terminal block adjacent to the main PCB. If it must be changed, be sure to replace it with one with the same rating. The fuses in the V1305R-DC are: 120 VAC, 1 A slo blo (delay);...
  • Page 36: Shipping Instructions

    Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
  • Page 37: Technical Information

    Radio Frequency Emission Rating: FCC Class A. European Community (CE) Standard: Emissions: EN 55022: 1994 +A1: 1995 +A2: 1997. Harmonic Emissions: EN61000-3-2: 1995+A1: 1998+A2: 1998. Flicker: EN6100-3-3: 1995. Immunity: EN 50130-4: 1995+A1:1998. Technical Information • • 25 X992 Rev 202 V1305R-DC...
  • Page 38 -40° to 140°F (-40° to 60°C) with heater. Operating Humidity: Up to 95% relative, noncondensing. Storage Temperature Range: -20° to 140° F (-29° to 60°C). Storage Humidity: Up to 85% relative, noncondensing. Water Resistance: IP65. 26 • • Technical Information X992 Rev 202 V1305R-DC...
  • Page 39 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-CCTV (2288) 800-645-9116 Fax: 631-951-CCTV (2288) Infofax: 800-287-1207 Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom 44/(0) 1489/566300 Fax: 44/(0) 1489/566322 Brussels Office Planet II - Unit E...