1. Introduction

VF-S15 has trace function to retain the data at tripping and at triggering and to read out such
data until resetting the tripped inverter or turning off the power.
Up to 4 types of data can be selected from approximately 25, and 100 consecutive points can
be stored as trace data, which is useful for determining the cause.
RS485 communication and the software for trace function, PCT002Z-E, are used for VF-S15.
Use PC to read data.
*1: Please contact your Toshiba distributor for the software:PCT002Z-E.
*2: USB converters unit (optional), USB cable (optional, A-B connection type), and
commercially available USB cable are necessary to connect to the PC.
Refer to the Trace tool PCT002Z-E Instruction Manual (E6581857) for usage and connection.
PCT002Z-E cannot be used for trace function of VF-AS1 and VF-PS1.
 Inverter interconnect cable (optional)
Model number
CAB0011
CAB0013
CAB0015
Fig. 1 An example of connection of USB converters unit
Cable length
1.2m
3.6m
4.8m
 Model No. of USB converters
RS485 (2-wire
LOGIC
USB
Option Unit
USB
 USB cable (A-B connection type)
Prepare a commercially available USB cable
(USB1.1/2.0-compliant).
Recommended cable length: 1m
E6581922
unit: USB001Z (optional)