Superior VCM3026ZTN Installation And Operation Instructions Manual page 14

Unvented (vent-free) compact fireplaces

Advertisement

Mantel Clearances for Built-In Installation
If placing mantel above built-in © replace, you
must meet minimum clearance between man-
tel shelf and top of © replace opening.
NOTICE: Surface temperatures of adjacent
walls and mantels become hot during
operation. Walls and mantels above the
fi rebox may become hot to the touch. If
installed properly, these temperatures meet
the requirement of the national product
standard. Follow all minimum clearances
shown in this manual.
NOTICE: If your installation does not meet
the minimum clearances shown in Figure
11 , you must do one of the following:
• raise the mantel to an acceptable
height
• remove the mantel
Minimum clearance requirements include
any projections such as shelves, window
sills, mantels, etc. above the appliance.
10"
Note:
8"
All vertical
measurements
6"
are from top of
1
2
/
"
fireplace
2
opening to
bottom of
mantel shelf. All
measurements
are in inches.