,&,WARNING
CBX32M
units are factory-configured
for up-flow
or
horizontal right-hand discharge installation. For down-flow
or horizontal left-hand discharge, some field modification
is required.
WARNING
IMPORTANT
The Lennox Elite* Series CBX32M air handler units are
designed for installation with a matched remote outdoor
unit that is charged with HFC-410A refrigerant and optional
field-installed
electric heat, The air handler units are for
indoor installation only.
These instructions are intended as a general guide and do
not supersede local or national codes in any way. Consult
authorities having jurisdiction
before installation. Check
equipment for shipping damage; if found, immediately
report damage to the last carrier.
Package 1 of 1 contains the following:
1--Assembled
air handler unit
In addition to conforming
to manufacturer's
installation
instructions and local municipal building codes, installation
of Lennox air handler units (with or without optional electric
heat), shall conform
with the following
National
Fire
Protection Association (NFPA) standards:
NFPA No. 90A - Standard for Installation of Air
Conditioning and Ventilation Systems
NFPA No. 90B - Standard for Installation d Residence
Type Warm Air Heating and Air Conditioning Systems
This
unit
is approved
for
installation
clearance
to
combustible material as stated on the unit rating plate,
Accessibility
and
service
clearances
must
take
precedence over combustible material clearances.
DISASSEMBLE AND REASSEMBLE
AIR HANDLER
UNIT
The CBX32M air handler unit consists of two sections
which
are shipped
assembled
from
the
factory,
If
necessary,
the unit may be disassembled
to facilitate
setting the unit, Follow the steps below:
To disassemble:
Step 1_
Remove access panels.
Step 2..
Remove both blower and coil assemblies. This
will lighten the cabinet for lifting,
Step 3..
Remove one screw from the left and right posts
inside the unit. Remove one screw from each
side on the back of the unit, Unit sections will
now separate,
To reassemble:
Step 1.. Align cabinet sections together,
Step 2,,
Reinstall screws,
Step 3..
Replace blower and coil assemblies.
Step 4,,
Replace access panel.
UP-FLOW APPLICATION
Use the following
procedures to configure the unit for
up-flow operations:
Step 1..
Remove access panels. Remove corrugated
padding from the space between the blower and
coil assemblies.
Step 2..
The horizontal drain pan must be removed when
the coil blower is installed in the up-flow position,
Removing horizontal drain pain will allow proper
airflow and increase efficiency.
Step 3..
Place unit in desired location. Make sure that
unit is level, Connect
return and supply air
plenums as required using sheet metal screws
as illustrated in figure 1,
Step 4..
Install units which have no return air plenum on
a mounting stand that is at least 14" from the
505342M
05/08
Page 4