Rs-232 Control Port - B&K 13790 1104 User Manual

Seven channel surround a/v preamplifier processor
Table of Contents

Advertisement

36

RS-232 Control Port

The RS-232 port refers to the main RJ-45 connection
located on the preamplifier's back panel. The RJ-45
contains connections for transmission and reception of
RS-232 data. See pin-out at right. The RJ-45 also
supports power supply and IR input for CK1.2 Keypad
interface.
Port - When disabling the RS-232 port, RS-232 strings
will be neither transmitted nor received through the
main RJ-45 jack. By default the RS-232 port is enabled.
Baud rate - The default baud rate is 9600. B & K does not recommend using any baud rate other than 9600.
When a Baud rate other than 9600 is used, Keypad status will not function.
Echo - Enabled or Disabled. This setting is for those with external control systems communicating to B & K
products via RS-232. Echo will repeat RS-232 transmissions received through the main RJ-45 receive port.
Feedback (RS-232 Continuous Reply):
None (Default) = Neither BKC-DIP Update or Reply is generated.
Update = A change affecting a logical zone from the Front Panel or
B & K IR generates an update message representing the specific front panel
button or B & K IR command. The preamplifier must then be polled to deter-
mine the current status.
Reply = When set to "REPLY", the preamplifier will automatically
generate BKC-DIP reply messages to allow unsolicited continuous feedback
to an external RS-232 controller. A change affecting Zone A or Zone B from
the Front Panel or B & K IR generates a reply message representing the new
status of the parameter that was changed.
Typical format example of a BKC-DIP Reply :
An example BKC-DIP Reply message the Reference 50 Series2 will automatically generate when a master
volume change is executed in Logical Zone 1 is (0,R,P1=FF,1=60;). Reply message Logical Zone 1 current
Preset parameter Volume value is set to 60 hex or 0dB (assumes 0dB is the current setting).
"0" is the transmit ID
"R" is the BKC-DIP Reply message.
"P1=FF" is the BKC-DIP command for the current preset in logical Zone 1 (P1: main theater zone ID).
"1=60" is the current preset parameter (1: Volume), is set to the Hex value of 60 (volume at 0dB ).
For a complete list of B & K RS-232 parameter Protocol, see the Series_IIIS2_10000.pdf or greater located in
the documentation of BKcSuite or online at B & K 's website.
All (Both) = Outputs both a BKC-DIP Update and Reply messages.
Receive ID / Transmit ID - This is the identifier in B & K RS-232 protocol that allows B & K to "listen" (receive
ID) or "talk" (transmit ID) to other B & K products. Change this identifier if you are using an external automa-
tion system to control more than one B & K products in series. The transmit and receive IDs are denoted by
the first number in an RS-232 message i.e. (0,S,I,1=45;).
Note - If you change the Receive or Transmit ID, it does not affect setup with BKcSuite.
ADVANCED MENU SYSTEM SETUP
12v
TX
RCV
IR
12v
IR
TX
RCV
CTR
12v
CTR
1 1 P P o o r r t t
2 2 B B a a u u d d r r a a t t e e
3 3 E E c c h h o o
4 4 F F e e e e d d b b a a c c k k
5 5 R R e e c c e e i i v v e e I I D D
6 6 T T r r a a n n s s m m i i t t I I D D
↑ ↑ ↓ ↓ n n e e x x t t i i t t e e m m
M M E E N N U U a a d d v v a a n n c c e e d d s s e e t t u u p p
12VDC Power Supply
Signal/Common Ground
RS-232 Host Transmit
RS-232 Host Receive
IR Input
12VDC Control Output
R R S S - - 2 2 3 3 2 2 P P O O R R T T S S E E T T U U P P
E E n n a a b b l l e e d d
9 9 6 6 0 0 0 0
D D i i s s a a b b l l e e d d
N N o o n n e e
E E N N T T s s e e l l e e c c t t
0 0
0 0