PB Heat Peerless Partner PV-40 Operation And Installation Manual

Pv series indirect fired water heater

Advertisement

Operation and Installation Manual
®
®
Peerless
Partner
PV
Series Indirect Fired Water
Heater
Limited Warranty and Tank
Replacement

Advertisement

Table of Contents
loading

Summary of Contents for PB Heat Peerless Partner PV-40

  • Page 1 Operation and Installation Manual ® ® Peerless Partner Series Indirect Fired Water Heater Limited Warranty and Tank Replacement...
  • Page 2: General Information

    PLEASE READ INSTRUCTIONS COMPLETELY BEFORE INSTALLING WATER HEATER IMPORTANT OWNER’S RESPONSIBILITY PB Heat, LLC (herein called the Company) specifically does not expressly or impliedly warrant the merchantability or the fitness for any particular purpose or the performance of the heater within that system, nor does it assume liability for any consequential damage to general property or other components of the system.
  • Page 3: Table Of Contents

    INDEX GENERAL INFORMATION ...................... 1 INDEX ............................2 SPECIFICATIONS ........................3 INSTALLATION GUIDELINES ....................4 INSTALLATION CHECKLIST ....................9 SERVICE INFORMATION...................... 11 MAINTENANCE ........................14 THERMOSTAT DIAGRAM 1 ....................15 THERMOSTAT DIAGRAM 2 ....................15 THERMOSTAT DIAGRAM 3 ....................16 THERMOSTAT DIAGRAM 4 ....................
  • Page 4: Specifications

    SPECIFICATIONS ® ® Peerless Partner PV Tank Dimensions Domestic Water Boiler Connection Height (to Tank Diameter, Connection Sizes, NPT Sizes, NPT connections), Inch Inch 3/4” 3/4" 40.5" 22.75" 3/4” 3/4” 28” 41" 1 - 1/2” 1” 28” 53.5" 1 - 1/2” 1”...
  • Page 5: Installation Guidelines

    INSTALLATION GUIDELINES A. INSPECTING AND PREPARING THE HEATER  Remove the cardboard box, which comes packaged with the heater. It should contain the following: Thermostat, T&P valve, brass “T”, insulation, lid and screws.  Do not cover or damage the temperature and pressure relief valve opening located in the topside of the tank (See FIGURE 1 and FIGURE 2).
  • Page 6 C. PROTECTION FROM WATER DAMAGE  CAUTION: All water heaters have a risk of leakage at some unpredictable time. IT IS THE CUSTOMER’S RESPONSIBILITY TO PROVIDE  A CATCH PAN OR OTHER ADEQUATE MEANS, SO THAT THE RESULTANT FLOW OF WATER WILL NOT DAMAGE FURNISHINGS OR PROPERTY.
  • Page 7  WARNING: IF THE WATER SUPPLY IS FROM A WELL, OR KNOWN TO HAVE HARD WATER, IT IS RECOMMENDED TO USE A PRESSURE RELIEF VALVE IN THE COLD WATER LINE AS WELL AS A T&P VALVE IN THE HOT WATER LINE. ...
  • Page 8 �������� ���������������� ������ �������� ����������ℎ = (�� ∗ �������� ������������ ∗ �������� ������������) NOTE: Be sure to connect Boiler Supply Line (from the boiler) to the “HX in” fitting and Boiler Return Line (to the boiler) to the “HX Out” fitting. Construction of Single Wall Heat Exchanger ...
  • Page 9 ETC101 WIRING CONTROLS WARNING: Do not use ETC101 with 110V circuits.  For controlling zone valves, multi-zone controllers and switching relays, follow applicable wiring diagrams for typical low voltage thermostat circuits. J. INSULATION INSTALLATION  Place included fiberglass insulation between and around the water supply and boiler supply connections.
  • Page 10: Installation Checklist

    INSTALLATION CHECKLIST A. INSPECTING AND PREPARING THE HEATER  Remove the cardboard box, which comes packaged with the heater. It should contain the following: Thermostat, T&P valve, brass “T”, insulation, lid and screws.  Do not cover T&P relief valve opening. B.
  • Page 11  If there is a check valve (sometimes in water meter), backflow preventer or pressure-reducing valve, install an adequate size expansion tank. G. FILLING THE HEATER  Water connections completed and free of leaks.  Check for proper installation of relief valve. ...
  • Page 12: Service Information

    SERVICE INFORMATION WATER TEMPERATURE REGULATION WARNING: Exposure to 125° F or hotter water can cause scalding injuries. Appropriate caution must be taken when using hot water. Special supervision must be given to those who cannot act quickly such as children, invalids or elderly persons.
  • Page 13 A. WATER TEMPERATURE CONTROLS  A periodic inspection of the operating controls, heat exchanger and wiring should be made by qualified service personnel.  Temperature of the water should be tested periodically at the faucet to be sure thermostat is working properly. B.
  • Page 14 Indicator LED operation:  The thermostat has an indicator LED at the top of the case. (See THERMOSTAT DIAGRAM 1 or Inside Cover of Thermostat)  When thermostat is calling for heat, the Indicator LED will flash green.  When thermostat is satisfied, the Indicator LED will be solid green.
  • Page 15: Maintenance

    MAINTENANCE Properly maintained, your water heater can provide years of dependable, trouble free service. It is suggested that the purchaser follow the preventive maintenance program outlined below. A. CONTROLS  A periodic inspection of the operating controls, heat exchanger and wiring should be made by qualified service personnel.
  • Page 16: Thermostat Diagram 1

    THERMOSTAT DIAGRAM 1 THERMOSTAT DIAGRAM 2...
  • Page 17: Thermostat Diagram 3

    THERMOSTAT DIAGRAM 3 ETC101 (Low Voltage Only) THERMOSTAT DIAGRAM 4 Inserting the probe wires into the press release connector 4.A – Position tool on top of white buttons 4.B – Push Down on buttons and push wires Down into holes in top of connector (This can also be done one side at a time) 4.C –...
  • Page 18: Etc101 Thermostat Diagram 5

    ETC101 THERMOSTAT DIAGRAM 5 * For Newer Switching Relay Panels: Some models do not work with “Power Stealing” thermostats. The ETC101 is a power stealing thermostat unless powered separately from the TT terminals as shown in the 3-wire or 4-wire configuration. See also wiring diagrams on subsequent pages.
  • Page 19: Zone Relay Wiring, R845 Or 829A

    Zone Relay Wiring, R845 or 829A PureFire® Boilers Alternate Wiring - a 24VAC transformer may be used to power the Partner® ETC101 limit control (24V terminals) in lieu of using a zone relay. Connect Partner T-T terminals and Partner circulator directly to PureFire DHW Switch terminals and DHW Pump terminals.
  • Page 20: Zoning Panel With Hydrostat 3250 Oil Boiler Control (Sr503 Shown)

    Zoning Panel with HydroStat 3250 Oil Boiler control (SR503 shown) Zoning Panel with PureFire® Boiler (SR503 shown)
  • Page 21: Figure 1

    FIGURE 1 Installation Diagram Using Zone Valves Note: PV80 and PV120 have 1 inch HX fittings and 1 1/2 inch hot and cold fittings. FIGURE 2 Installation Diagram Using Separate Circulator...
  • Page 22: Figure 3

    FIGURE 3 ® ® Typical Piping Peerless PureFire Boiler...
  • Page 23: Figure 4

    FIGURE 4...
  • Page 24: Parts List

    PARTS LIST T&P Relief Valve – Located above and to the left of hot  water outlet. Temperature Control – Temperature controls are  specifically designed for Peerless® Partner® PV Series water heaters. Temperature sensors are located under the plastic jacket and may be located using the template provided in the replacement kit.
  • Page 25: Repair Parts

    REPAIR PARTS Repair Parts are available from your local PB Heat, LLC distributor or from Parts-To-Your-Door at 1 (610) 916- 5380 (www.partstoyourdoor.com). Note: Remember to include the model number and serial number when ordering parts. REPAIR PARTS Item Stock Code...
  • Page 26: How To Obtain Service Assistance

    HOW TO OBTAIN SERVICE ASSISTANCE PB Heat, LLC does not have a service department or personnel to service your heater in the field. A qualified installer or service technician must do all service work. Therefore, if you have any questions about your new water...
  • Page 27: Peerless® Partner® Pv Series Indirect Fired Water Heater 10/2 Limited Warranty

    Two Year Limited Tank Replacement Labor Allowance One Year Limited Parts Warranty PB Heat, LLC, (hereinafter called the company) offers the following Limited Tank Replacement Policy, Limited Tank Replacement Labor Allowance, and Limited Parts Warranty to the original purchaser/owner of this stone-lined Peerless® Partner® PV Series indirect water heater.
  • Page 28 This labor allowance is for tank replacement only, and not for any service work on the heater such as cleaning of the heat exchanger (due to the build-up of calcium or other minerals or metals), leakage from plumbing connections, relief valves, heat exchanger gaskets, thermostats, or any other component of the heater.
  • Page 29 The following information should be noted At time of installation and retained for future reference. Model No. Serial No. Date Installed Dealer’s Name Address City State 131 S Church Street, Bally, PA 19503 Revision 1.3...
  • Page 30: Notes

    NOTES...
  • Page 31: Product Registration And Optional Lifetime Warranty Purchase Card

    Optional Lifetime Warranty on newly purchased tanks (Not available on replacement tanks), may be purchased by completing and returning this form to PB Heat, LLC along with a payment of $249 within 30 days of installation / occupancy. Optional Ten Year Extended Warranty (Replacement tanks only):...