MicroAire 7500-700 Instructions For Use Manual

Hide thumbs Also See for 7500-700:

Advertisement

Quick Links

7500-700 Battery Charger

Instructions for Use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7500-700 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MicroAire 7500-700

  • Page 1: Battery Charger

    7500-700 Battery Charger Instructions for Use...
  • Page 2: Table Of Contents

    Table of Contents REF 7500-700 Battery Charger Instruction Manual Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 General Warnings .
  • Page 3: Introduction

    Introduction The MicroAire REF 7500-700 Battery Charger has been designed to charge all MicroAire 14 . 4 volt NiMH battery packs . This manual has been written to help describe the procedures required to keep the MicroAire Battery Charger system operating properly .
  • Page 4: Markings

    . ALWAYS decontaminate a battery pack exposed to infectious material before sending it to a waste treatment facility . European Conformity Mark with MicroAire’s Notified Body Number MEDICAL-GENERAL MEDICAL EQUIPMENT AS TO ELECTRIC SHOCK, FIRE, AND MECHANICAL HAZARDS ONLY .
  • Page 5: Setup

    OPERATION 1 . Verify that the “Standby” LED is on . 2 . Insert a MicroAire REF 6640-710 or REF 7505- 710 Battery into any slot . The battery can only be inserted on the charger in one position .
  • Page 6: Shipping & Environmental Parameters

    . SERVICES AND REPAIR Periodic inspection and factory service is essential to keep precision MicroAire instruments running properly . If repairs are required, they can be accomplished quickly with a minimum of disruption to the hospital’s schedule .
  • Page 7 All MicroAire equipment should be inspected and tested periodically in accordance with the facility’s Bio-Engineering policy . Such service should be documented within the Bio-Engineering Department . MICROAIRE REPAIR SERVICE Responsive service comes with every MicroAire product . If a problem arises, contact our Customer Service Department at: USA: (800) 722-0822 / (434) 975-8000 Fax: (434) 975-8010 inquiry@microaire .com...
  • Page 8: Warranty

    The MicroAire REF 7500-700 Battery Charger system is intended for use in the electromagnetic environment specified below . The customer or the user of the MicroAire REF 7500-700 Battery Charger system should assure that it is used in such an environment .
  • Page 9 The MicroAire REF 7500-700 Battery Charger system is intended for use in the electromagnetic environment specified below . The customer or the user of the MicroAire REF 7500-700 Battery Charger system should assure that it is used in such an environment .
  • Page 10 The MicroAire REF 7500-700 Battery Charger system is intended for use in the electromagnetic environment specified below . The customer or the user of the MicroAire REF 7500-700 Battery Charger system should assure that it is used in such an environment .
  • Page 11 The MicroAire REF 7500-700 Battery Charger system is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled . The customer or the user of the MicroAire REF 7500-700 sys- tem can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the MicroAire REF 7500-700 system as recommended below, according to the maximum output power of the communications equipment .
  • Page 12 11, rue Emile Zola - BP 2332 Charlottesville, Virginia 22911 USA F-38033 Grenoble Cedex 2 Phone: (800) 722-0822 (434) 975-8000 France Order Fax: (800) 648-4309 or (434) 975-4131 www .microaire .com ©2017 MicroAire Surgical Instruments LLC | IM-7500-700, Rev . H, Printed in USA...