Din-Rail Mounting Installation - Compal U-BPC User Manual

Ultra-compact fanless embedded pc
Table of Contents

Advertisement

A.3 DIN-rail Mounting Installation
Mounting on a standard rail is suitable for horizontal mounting of the device.
Requirement
A standard 35 mm rail. The standard rail is mounted.
A standard rail bracket (the standard rail bracket and two screws are included in the order
variant "Standard rail mounting")
A PH1 screwdriver
1
2
3
Procedure for Dismantling
-
Using a screwdriver to loosen the four
screws located in the bottom of your
U-BPC.
-
Align the screw holes and put the VESA
mount brackets into position.
-
Screw back the four screws.
-
Place DIN-rail bracket horizontally (or
vertically, check below next figure)
according to the field site condition or
your installation needs.
-
Following the step above and turn
DIN-rail bracket 90 degree.
-
Press the device down and toward the
standard rail until the standard rail
bracket engages.
-
Check whether the device is seated
firmly on the standard rail
- 40 -