Troubleshooting; Technical Data; Guaranteed Sound Power Level - Qualcast Y0R-SP01-120 Assembly Manual

18v li-ion cordless leaf blower
Table of Contents

Advertisement

Troubleshooting

General Troubleshooting
WARNING! Only perform the steps described within these instructions!
All further inspection, maintenance and repair work must be performed by an authorised
Service centre or a similarly qualified specialist if you cannot solve the problem yourself!
Suspected malfunctions, disturbances or damages are often due to causes that the user can fix
themselves. Therefore check the product using this section. In most cases the problem can be
solved quickly.
Fault
Possible Cause
Product does not
1. Not connected to battery pack
start
2. Power connection is loosen
3. Battery pack is lack of power
4. Battery too hot/too cold
Product does not
1. Battery pack has too low
reach full power
voltage
2. Air vents are blocked
Unsatisfying result
1. Blower tube blocked
2. Electrical malfunction
3. Fault in battery
Customer Helpline 0845 034 2279
12
www.gardenservicecentre.co.uk
Solution
1. Connect to battery pack
2.Connect the battery pack and tool
well
3. Fully charge the battery pack
4. Allow battery to cool down / warm
up battery slowly at a temperature of
15
C-25
C
o
o
1. Charge the battery pack to full
power
2. Clear the air vents
1. Have a specialist to replace it
2. Have a specialist to replace it
3. Have a specialist to replace it

Technical Data

Appliance
Voltage..................................................................................................................18V DC
Max. Air speed......................................................................................................125 mph
Battery type..............................................................................................................Li-ion
Battery capacity.........................................................................................................1.5Ah
Battery charging time..................................................................................................1 hour
Measured sound pressure level .......................................................................74.3dB (A), k=3 dB (A)
Measured sound power level......................................................................85dB (A), k=3dB (A)
Guaranteed sound power level .....................................................................................88dB (A)
Vibration.......................................................................................................2.2m/s
The declared vibration value has been measured in accordance with a standard test method and
may be used for comparing one tool with another. The declared vibration value may also be used in
a preliminary assessment of exposure.
WARNING! The vibration emission value during actual use of the tool can differ from the declared
value depending on the ways in which the tool is used. Identify safety measures to protect the
operator that are based on an estimation of exposure in the actual conditions of use (taking account
of all parts of the operating cycle such as the times when the tool is switched off and when it is
running idle in addition to the trigger time).
The sound intensity level for the operator may exceed 85dB(A) and ear protection measures are
necessary.
Customer Helpline 0845 034 2279
www.gardenservicecentre.co.uk
2
,k=1.5m/s
2
13