F u ll H D (6 0 H z ) 6 7 . 5 V E SA * 1 ) O n ly f or [ X G A M od el] * 2) O n ly f or [ W X G A M od el] 8950W 8952...
Page 2
Supported signals Su p p orted s i gn als f or H D M I Res o lu ti on (H x V ) Si gn al m od e H . f req u en cy V . f req u en cy Rati n g (k H (H z )
Page 3
Supported signals Su p p orted s i gn als f or M H L Res o lu ti on (H x V ) Si gn al m od e H . f req u en cy V . f req u en cy Rati n g (k H (H z )
Page 4
Connection to the ports Connection to the ports NOTICE ►Use the cables with straight plugs, not L-shaped ones, as the input ports of the projector are recessed. COM P U TE R I N1 , COM P U TE R I N2 / M ONI TOR OU T D-sub 15pin mini shrink jack <...
Page 5
Connection to the ports (continued) V I D E O RCA jack • System: NTSC, PAL, SECAM, PAL-M, PAL-N, NTSC4.43, PAL (60Hz) • 1.0±0.1Vp-p, 75Ω terminator H D M I 1 , H D M I 2 / M H L 10 12 14 16 18 •...
Page 6
Connection to the ports (continued) AU D I O I N1 , AU D I O I N2 Ø3.5 stereo mini jack • 47kΩ terminator AU D I O I N3 AU D I O OU T RCA jack x2 Ø3.5 stereo mini jack •...
Page 7
Connection to the ports (continued) CONTROL D-sub 9pin plug • About the details of RS-232C communication, 3 2 1 please refer to the next chapter. P i n Si gn al P i n Si gn al P i n Si gn al (No con n ecti on ) (No con n ecti on )
Page 8
Connection to the ports (continued) To i n p u t c o m p o n e n t v i d e o s i g n a l t o COM P U TE R I N p o r t s ex .
RS-232C Communication RS-232C Communication When the projector connects to the computer by RS-232C communication, the projector can be controlled with RS-232C commands from the computer. For details of RS-232C commands, refer to RS-232C Communication / Network command table (&18). Connection Turn off the projector and the computer.
RS-232C Communication (continued) Communication settings 1. Protocol 19200bps,8N1 2. Command format ("h" shows hexadecimal) Byte Number Com m an d H ead er D ata H ead er D ata Setti n g Acti on Ty p cod e s i z e flag cod e P ack et...
Page 11
RS-232C Communication (continued) 3. Response code / Error code ("h" shows hexadecimal) ( 1 ) ACK r e p l y : 0 6 h When the projector receives the Set, Increment, Decrement or Execute command correctly, the projector changes the setting data for the specified item by [Type], and it returns the code.
Page 12
Command Control via the Network Command Control via the Network When the projector connects network, the projector can be controlled with RS- 232C commands from the computer with web browser. For details of RS-232C commands, refer to RS-232C Communication / Network command table (&18).
Command Control via the Network (continued) Communication Port The following two ports are assigned for the command control. TCP # 23 TCP # 9 7 1 5 Configure the following items form a web browser when command control is used. P o r t S e t t i n g s Click the [ E n a b l e ] check box to open [ N e t w o r k Co n t r o l P o r t 1 ( P o r t : 2 3 ) ] to u s e TCP # 23.
Command Control via the Network (continued) Command control settings [ TCP # 2 3 ] 1. Command format Same as RS-232C communication, refer to RS-232C Communication command format. 2. Response code / Error code ("h" shows hexadecimal) Four of the response / error code used for TCP#23 are the same as RS-232C Communication (1)~(4).
Page 15
Command Control via the Network (continued) 2. Response code / Error code ("h" shows hexadecimal) The connection ID is attached for the TCP#23's response / error codes are used. The connection ID is same as the sending command format. (yyh : connection ID) ( 1 ) ACK r e p l y : 0 6 h + y y h ( 2 ) NAK r e p l y : 1 5 h + y y h ( 3 ) E r r o r r e p l y : 1 Ch + 0 0 0 0 h + y y h...
Page 16
Network Bridge Communication Network Bridge Communication This projector is equipped with NETWORK BRIDGE function. When the projector connects to the computer by wired or wireless LAN communication, an external device that is connected with this projector by RS- 232C communication can be controlled from the computer as a network terminal. For details, see the 7 .
Page 17
Network Bridge Communication (continued) Communication settings For communication setting, use the OPTION - SERVICE - COMMUNICATION m en u . (&OPTION menu - SERVICE - COMMUNICATION in the Operating Guide) I tem Con d i ti on BAUD RATE 4800bps / 9600bps / 19200bps / 38400bps Data length 8 bit (fixed) P ARI TY...
RS-232C Communication / Network command table RS-232C Communication / Network command table Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e...
Page 19
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e BE EF...
Page 20
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e G e t...
Page 21
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e G e t...
Page 22
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e 4 : 3...
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e A UTO...
Page 24
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e G e t...
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e G e t...
Page 26
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e G e t...
Page 27
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e OF F...
Page 28
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e ENG L IS H...
Page 29
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e My S c r e e n...
Page 30
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e NORMA L...
Page 31
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e COMPUTER IN1...
Page 32
RS-232C Communication / Network command table (continued) Co m m a n d Da t a Na m e s Op e r a t i o n Ty p e H e a d e r A c t i o n Ty p e S e t t i n g Co d e OF F...
PJLink command P J L i n k com m an d Com m an d s Con trol D es c r i p ti on P aram eter or Res p on s e 0 = Standby P O W R P ow er Con trol 1 = P ow er O n 0 = Standby...
Page 34
Projector Name inquiry NAME" of "NETWORK" I NF 1 ? Brand Name inquiry H I TACH I / DUKANE CP-EX5001WN / 8952 I NF 2 ? M od el Nam e i n q u i ry CP-EW5001WN / 8950W...