SPECIFICATIONS
Minimum Supply Pressure
Maximum Supply Pressure
Regulating Pressure Range
Voltage
Power Supply
Current
Consumption
Current
Input Signal
Voltage
Input
Current
Impedance
Voltage
Analog
Output
Monitor Output
Pressure
Achieved
Linearity
Hysteresis
Repeatability
Sensitivity
Output
Accuracy
Display
Minimum unit
Temperature Range
Enclosure
Weight
PIN
Euro Color Code
1
Brown
.10
(3)
2
White
3
Blue
4
Black
.38
3
(10)
4
2
1
Pin 4
Monitor
Output
Pin 1
+24VDC
1.00
(25)
Set Pressure + 15 PSI (1 BAR)
150 PSI (10 BAR)
0-100 PSI
24V DC ±10%
0.04 A
4-20mA
0-5VDC, 0-10VDC
< 250 Ω
4.8 KΩ
0-5VDC
0-10VDC
4-20mA
24VDC (PNP)
< ±1% of span
< ±.5% of span
< ±.5% of span
< ±.2% of span
±.5% PSIG
PSI 0.1, BAR 0.01, kPa 001.,
kgf/cm² 0.01
40-120°F
4-50°C
IP65 Equivalent/NEMA 4
1.4lbs (0.64kg)
2
Description
Supply Power +24VDC
Command Signal
Common 0 VDC
Command Source
Common
Monitor Output
+
0VDC
+
4
3
2
1
+24VDC 0VDC
Common
Pin 3
Power Source
Common
0VDC
Pin 2
Command
4
Monitor

Advertisement

loading
Need help?

Need help?

Do you have a question about the E22 and is the answer not in the manual?

Questions and answers

Summary of Contents for Numatics E22

  • Page 1 SPECIFICATIONS Minimum Supply Pressure Set Pressure + 15 PSI (1 BAR) Maximum Supply Pressure 150 PSI (10 BAR) Regulating Pressure Range 0-100 PSI E22 Operation Manual Voltage 24V DC ±10% Power Supply Current 0.04 A Consumption Current 4-20mA Input Signal...
  • Page 2 Initial Settings Locked Mode Mode (Hold SET for 3 sec) E22 Series E22 Series Press and hold the up and down arrow buttons for 10 seconds to activate the locked mode with will Units: be displayed by a “L”. To unlock the...