Pairing The Detector:
Step 1 - Activate The Receiver
Press & hold the 'programming' button on the receiver for 2 seconds
(the status LED will flash with a 1 second interval).
Programming button
Press and hold 2
seconds
Step 3 - To Prepare For Function 5
Switching Actuator Function 5 - 'OFF DELAY'
Remove battery - wait 30 seconds
Re-insert battery to set time delay mode
Remove for another 30 seconds
Press button on receiver for < 5 seconds to start counter
When required time elapsed re-insert battery
Battery Replacement
Always replace both battery cells at the same time.
We recommend using a high quality brand name battery (e.g. Panasonic).
After the batteries have been replaced, detector function should be tested.
Expired batteries should be disposed of according to local regulations.
Technical Specifications
Battery Type:
Voltage:
Typical battery life:
Communication band:
Communication range:
Operational environment according to EN 50131-1
Operational temperature range:
Dimensions:
EN 50131-1, CLC/TS 50131-2-2, EN 50131-5-3 classification:
Complies with:
Can be operated according to:
Scolmore Park, Landsberg, Lichfield Road Industrial Estate, Tamworth, Staffordshire B79 7XB
Tel: +44 (0) 1827 63454
Status LED
Will flash once per
second
Select A or B To Delete Stored Function
A. Press and hold programme button for
5 seconds the LED will flash twice a second.
Remove and re-install batteries - this will delete
the single pairing.
B. Press and hold programme button for
8 seconds - this will delete ALL stored functions
Release programming button and then press for <1 second to exit
Fax: +44 (0) 1827 63362
Step 2 - Assign The Device
Remove cover to reveal battery compartment
Insert the battery, replace the cover, after ten
seconds close and open the door / window, the
receiver LED will flash at an increased speed
once to confirm detector assignment.
The device will now switch on / off without any delay.
To programme an off delay proceed to the next step, to
exit programming proceed to step 4.
Step 4 - Save And Exit
To exit programming mode press the
programme button for 1 second only.
Replace the battery cover.
Press and hold for 1
second
CR123A Lithium
3.0V DC
Approx. 3 years (for 20 daily activations)
868 MHz
Approx. 300m (open area)
II.indoor general
-10 to +40 °C
Transmitter: 75 x 31 x 23 mm
Magnet A: 56 x 16 x 15mm
Magnet B: 10mm diameter x 24mm
Grade 2
ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1
ERC REC 70-03
www.scolmore.com
V1.0