Wireless Digital Outdoor Dual Side-View Detector with 4x Dual Sensors
Installation Manual V2.5
Introduction
The wireless NVR780
incorporates two independent, side-by -side passive infrared detectors into a single housing. Covering up to 24 meters (12m
for each side), and configurable to report as a single unit (2 sides of the unit report to a single zone output) or dual units (each side reports to a
separate zone output), the NVR780 provides flexible and accurate boundary protection.
Installation
To install the NVR780:
1) Select the detector's location. Remove the front cover screws holding the cover into place; open the cover.
2) Mount the unit on a flat, even, clean surface. Mount the back plate to the wall by securing the included 1.5" screws (4x) in each of the
dedicated mounting holes. Secure the 2" screw in the dedicated wall tamper hole. IMPORTANT: Do not overtighten the tamper screw, it may
lead to water infiltration of the unit. Also, the unit must be installed at least 40 cm (15.7 in) away from the desired protected area (door,
window, etc.) when its sensitivity is set at 75% and 10 cm (3.9 in) when set at 100%. See Detector Settings below to set the sensitivity.
Enrollment
To enroll the NVR780 to the system, please refer to your respective panel's/receiver's Programming Guide. If you are assigning the zones of the
NVR780 via the anti-tamper switch, press once (under 1 sec.) to assign the first zone, and twice (under 1 sec. each) to assign the second.
Reporting (Zone Mode)
The NVR780 is configurable to report as a single unit (Single Mode: two sides of the unit report as a single zone) or dual units (Dual Mode: each
side reports as two separate zones). In Single Mode, report has only one S/N. In Dual Mode, report has two separate S/N, one for each side. Zone
Mode is configured via DIP switches. See Detector Settings below to set the Zone Mode to either Single or Dual. NOTE: In Dual Mode, the 'Cover
Tamper' is reported to zone 1, and the 'Wall Tamper' is reported to zone 2.
Walk-Testing
To put the detector into Walk-test Mode, open and close the cover, or unplug and then plug in the battery pack. Walk-test Mode lasts five minutes.
IMPORTANT: If the cover remains open, the unit will not be operational. When in Walk-test Mode, the unit will not go into Energy Save Mode.
Detector Settings
IMPORTANT: When changing DIP switch settings, the unit must be powered. To save changes, trigger the box tamper or close the cover.
DIP Switch#
Functionality
DIP Switch 1
LED
Enable (ON) or disable (OFF) the LED, (default = ON)
DIP Switch 2
Buzzer
Enable (ON) or disable (OFF) the buzzer, (default = OFF)
DIP Switch 3
Sensitivity (see table at right)
ON= 100% (High), OFF= 75% (Normal), (default =OFF)
DIP Switch 4
Zone Mode: Single/Dual
ON= Single Mode, OFF= Dual Mode, (default =ON)
Power-up Sequence
If the module is set in Single Mode:
• Both left and right LEDs blink simultaneously 4 times
• Buzzer activates (on/off beep: one tone)
Energy Save Mode
The NVR780 enters into Energy Save Mode after two detections within 5 minutes. In Energy Save Mode, both the LED
indication and buzzer indication are shorter than during normal operation. After 3 minutes, the module returns to transmission mode.

Battery Replacement

Replace the pack in its original orientation; the batteries must be facing up (towards PCB enclosure), and the connector must be on the left side.
Alarm
If the module is set in Single Mode:
• LED: red LED indication only on the relevant side(s) for 2 sec.
• Buzzer: activates (same tone for each side)
Firmware Upgrade via Built-in Serial Port
For upgrade instructions, refer to the Firmware Upgrade Instructions document which is available at paradox.com > Software > WinLoad.
If the module is set in Dual Mode:
• Both left and right LEDs blink alternately 4 times
• Buzzer activates (two tones, continuous)
If the module is set in Dual Mode:
• LED: red LED indication only on the relevant side(s) for 2 sec.
• Buzzer: activates, each side has its own tone. If there is an alarm
on both sides, there is a separate, third tone.
NVR780-EI04 Printed in Canada 02/2012
Min. and Max. Detection Coverage
The following is the minimum and maximum detection
coverage when the vertical beam adjustment is set at 0°.
Minimum
Coverage
75% Sensitivity
0.4m (1.3 ft.)
Level
100% Sensitivity
0.1m (0.3 ft.)
Level
Maximum
Coverage
11m (36 ft.)
23m (75.4 ft.)

Advertisement

loading

Summary of Contents for Paradox NVR780

  • Page 1: Battery Replacement

    Reporting (Zone Mode) The NVR780 is configurable to report as a single unit (Single Mode: two sides of the unit report as a single zone) or dual units (Dual Mode: each side reports as two separate zones). In Single Mode, report has only one S/N. In Dual Mode, report has two separate S/N, one for each side. Zone Mode is configured via DIP switches.
  • Page 2: Technical Specifications

    Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, and RE39406 and other pending patents may apply. Canadian and international patents may also apply. Trademarks: Paradox is a trademark of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. Certification: For the latest information on products approvals, please visit www.paradox.com.

This manual is also suitable for:

Nv780