Download Print this page

LIMBACH L 1700 Maintenance Instruction page 2

Advertisement

Part
Number
170.130.001
170.130.002
170.130.005
170.130.010
170.130.011
201.130.001
201.130.002
205.130.002
201.130.011
201.130.010
201.130.010
205.130.010
204.130.007
204.130.008
206.130.005
206.130.006
207.130.005
207.130.006
244.130.007
244.130.008
245.130.005
246.130.005
247.130.005
247.130.006
Checking float and float level
1. Unscrew screws (36) and remove float chamber (35) with gasket (34).
2. Pull off float (33) with float axle (32) from support.
3. Check float for leaks. Dip float totally into water of about 90 °C and check if air bubbles come up from
the float body. If this is the case the float has to be discarded.
4. Lock float with float axle into the support - the sparings of the float point to the carburetor housing.
5. Check float level. Turn carburetor with float to top and check level with gauge p/n: 803.001.005 above
raised and flat face of carburetor housing. Put the template onto the raised and flat face - both
chambers of the float lightly touch the lower edge of the template at its highest elevation, the weld
seam of the chambers is parallel to the raised and flat face. Correct float gage by bending the lever for
the float needle valve.
6. Mount float chamber with new gasket, coat center screws lightly with sealant (CURIL-T), tighten
screws.
Replacing float needle valve
1. Unscrew screws (36) and remove float chamber (35) with gasket (34).
2. Pull off float (33) with float axle (32) from the support.
3. Unscrew float needle valve.
4. Mount new float needle valve with new conical nipple.
5. Lock float with float axle into the support - the sparings of the float point to the carburetor housing.
6. Check float level.
7. Mount float chamber with new gasket, coat center screws lightly with sealant (CURIL-T), tighten
screws.
Bearb.: Stolinski
Gepr. + Freig.:
Maintenance Instruction
Engine Model
L 1700 E0
L 1700 EA
L 1700 EC
L 1700 EB left
L 1700 EB right
L 2000 E0, only RF5
L 2000 E0, EA, EC
L 2000 DA
L 2000 E0, only RF5
L 2000 E0, EC
L 2000 EA
L 2000 DA
L 2000 EB1.AA left
L 2000 EB1.AA right
L 2000 EB left
L 2000 EB right
L 2000 EB1.AB, AC left
L 2000 EB1.AB, AC right
L 2400 EB1.AA left
L 2400 EB1.AA right
L 2400 EE2
L 2400 EB1.AD
L 2400 EB1.AB, AC left
L 2400 EB1.AB, AC right
Replaces edition from: 13.09.96
Edition: 18.12.02
Float chamber
Jet needle valve
needle valve
Type
1,75
6A
1,75
6A
1,75
6A
1,75
6A
1,75
6A
1,75
6A
1,75
6A
1,75
6A
1,75
B2BA
1,75
B2BA
1,75
B2BA
1,75
B2BA
1,75
B5CK
1,75
B5CK
1,75
B5CK
1,75
B5CK
1,75
B5CK
1,75
B5CK
1,75
B5CK
1,75
B5CK
1,75
B5CK
1,75
B5CK
1,75
B5CK
1,75
B5CK
Page: 2 of 2 Pages
Reg.-Nr.: 041 Datei:
10.3
Adjustment
+2,0
0
+2,0
0
0
0
0
0
+1,5
+1,5
+1,75
+2,0
+2,0
+2,0
+2,0
+2,0
+2,0
+2,0
+2,0
+2,0
+2,0
+2,0
+2,0
+2,0
MI10-3.DOC

Advertisement

loading

This manual is also suitable for:

L 2400 ebL 2000L 2400 ee