5

Applications

• Single-channel E-Stop circuit, (up to category 2, EN ISO 13849-1: 2009)
• Two-channel E-Stop wiring with cross-circuit recognition (up to category 4, EN ISO 13849-1: 2009)
• Single-channel protective door monitoring (up to category 2, EN ISO 13849-1: 2009)
• Two-channel protective door monitoring (up to category 4, EN ISO 13849-1: 2009)
• Sequential circuit for safety sensor semiconductor outputs (two-channel, self-testing)
Figure 5.1:
Guarding a robot area with S400 safety hinge switch and MSI-SR4B safety relay