ABATEMENT PREDATOR  PRED750 Instruction Manual

ABATEMENT PREDATOR PRED750 Instruction Manual

Portable air scrubber

Advertisement

®
PREDATOR
PORTABLE AIR SCRUBBER
MODEL PRED750
INSTRUCTION MANUAL
ABATEMENT TECHNOLOGIES, INC.
U.S. PATENT D742495
CANADIAN PATENT 2852880
Abatement Technologies, Inc.
Abatement Technologies, Inc.
Abatement Technologies, Ltd.
Georgia, USA
Ontario, Canada
800-634-9091
905-871-4720
www. abatement.com
PRED750_MN2015.10.29

Advertisement

Table of Contents
loading

Summary of Contents for ABATEMENT PREDATOR PRED750

  • Page 1 ® PREDATOR PORTABLE AIR SCRUBBER MODEL PRED750 INSTRUCTION MANUAL ABATEMENT TECHNOLOGIES, INC. Ⓓ U.S. PATENT D742495 CANADIAN PATENT 2852880 Abatement Technologies, Inc. Abatement Technologies, Inc. Abatement Technologies, Ltd. Georgia, USA Ontario, Canada 800-634-9091 905-871-4720 www. abatement.com PRED750_MN2015.10.29...
  • Page 2: Key Components

    KEY COMPONENTS 1. First Stage Filter: 1" Deep Coarse Particulate Pre-filter (P/N F621) 2. Standard Second Stage Filter: 2" Deep Pleated Pre-filter (P/N H502) • Alternate Second Stage Filter: 2" High Capacity Vapor-Lock Carbon Filter (P/N VL1002) ® 3. Final Stage 99.97% HEPA Filter (P/N H161606-99) 4.
  • Page 3: General Information

    PREDATOR® Portable Air Scrubber Model: PRED750 Instruction Manual © Abatement Technologies 2015 All Rights Reserved. No reproduction of any portion of this work is permitted without the express written permission of Abatement Technologies, Inc. READ AND SAVE THESE INSTRUCTIONS! Note: Read and understand all operating instructions before using the Portable Air Scrubber.
  • Page 4 OVG can occur when the adsorption capacity of the filter is reached, replace the carbon filter as soon as odor breakthrough is sensed. More detailed information on carbon adsorption can be found in an article titled: “Activated Carbon: How Is It Used? How Does It Work?” which can be found on the Abatement Technologies website, www.abatement.com.
  • Page 5: Electrical Requirements

    Example: How many air filtration devices (each with 600 CFM rated airflow) would be required to provide 8 ACH (including a safety factor) in a 40ft L x 24ft W x 10ft H containment area? a. V = 40ft x 24ft x 10ft = 9600ft³ Design ACH = 8 c.
  • Page 6: Requirements For Safe Operation

    1. Never allow unauthorized individuals or children to operate the unit at any time. 2. Abatement Technologies urges anyone operating PREDATOR® air scrubber units to wear the proper personal protective equipment and follow safe work practices in accordance with federal, state, local, provincial and employer regulations.
  • Page 7: Operating The Unit

    exposure levels. Such atmospheres may require the use of intrinsically safe equipment, specific engineering controls, and personal protective equipment in accordance with Occupational Safety and Health Administration (OSHA), Environmental Protection Agency (EPA), Canadian Standards Association (CSA), and other federal, state, provincial and local regulations. Warning: This equipment is not classified as “intrinsically safe”...
  • Page 8: Daisy Chaining

    BEFORE OPERATING THE UNIT, NOTE THE FOLLOWING: Inspect and tighten any HEPA filter retaining nuts that may have loosened during transportation. Inspect the filters for any material or structural damage prior to use and replace any damaged filters before operating the unit.
  • Page 9: Filter Change Indicator

    on the prior unit, up to the maximum number allowed based on the amperage draw per unit. The National Electrical Code (United States) limits the total amperage draw of devices operating on one circuit to 80% of full load, which means that the total amperage draw on a 120V/ 15A circuit, including the unit plugged into the building electrical power supply receptacle, must not exceed 12 amps.
  • Page 10: User Servicing Instructions

    Wrap the cord as shown in the picture below and secure the plug head to the cord using the integrated clip. USER SERVICING INSTRUCTIONS Abatement Technologies' portable air scrubbers are designed to be low maintenance devices and basic maintenance should be performed as follows: •...
  • Page 11: Filter Replacement

    Caution: Abatement Technologies PREDATOR® Portable Air Scrubber units are designed to meet or exceed standards for high efficiency air filtration equipment. Use only Abatement Technologies parts, including replacement filters. Use of non-Abatement Technologies parts and filters voids the product warranty and all performance claims.
  • Page 12 HEPA filter efficiency rating. Warning: Use only Abatement Technologies pre-filters, HEPA filters, and replacement parts. Substitute parts void the warranty, jeopardize worker and environmental safety, and adversely affect engineered...
  • Page 13: Specification

    PRED750 SPECIFICATIONS FEATURE SPECIFICATION Net weight with filters: 35 lbs. Shipping weight: 43 lbs. Unit dimensions: 19.5"W x 25.5"L x 20.5"H Shipping carton dimensions: 20"W x 29"L x 21.5"H Power supply requirements: 110-120V, 60Hz, single phase, 15 amp circuit Normal operating amps: 1.9 amps or less Integrated circuit breaker: 12 amps...
  • Page 14: Troubleshooting Guide

    Note: If the unit does not start or malfunctions after carefully following the TROUBLESHOOTING GUIDE, call Abatement Technologies service department at 800-634-9091 (U.S.) or 905-871-4720 (Canada) for assistance. COMPONENT REPLACEMENT Warning: To reduce the risk of fire, electrical shock or personal injury, always turn the unit “OFF” and disconnect power cord from supply receptacle before removing the control panel, replacing the HEPA filter and before cleaning or servicing the unit.
  • Page 15: Certification Of Room Air Filtration Units

    Testing Laboratory (NRTL). LIMITED WARRANTY Abatement Technologies, Inc (ATI) warrants that goods sold to the original user shall be free from defects in material and workmanship for a period of 1 year, except such as are commercially acceptable. This warranty does not include useful filter life.
  • Page 19 PRED750 PART LIST ITEM PART NUMBER DESCRIPTION 1750 BODY 1751 DOOR 1752 OUTLET COVER 1755 MOTOR BRACKET BLOWER32 MOTORIZED IMPELLER H161606-99 HEPA FILTER 1757 HEPA HOLD DOWN BRACKET SCREW82 10-32X3/4" PAN HEAD SCREW H502 2" PLEATED FILTER F621 PRE-FILTER HARDWRE117 HEAVY DUTY PLASTIC HANDLE LATCH13 CAM LATCH...

Table of Contents