PerkinElmer 5182 Instruction Manual

Low-noise current

Advertisement

Model 5182
Low-Noise Current
Preamplifier
Instruction Manual
222514-A-MNL-C
Copyright © 2000 PERKINELMER CORPORATION

Advertisement

Table of Contents
loading

Summary of Contents for PerkinElmer 5182

  • Page 1 Model 5182 Low-Noise Current Preamplifier Instruction Manual 222514-A-MNL-C Copyright © 2000 PERKINELMER CORPORATION...
  • Page 2 Company Names PerkinElmer Instruments is part of Perkin Elmer, Inc., and includes the businesses formerly trading as EG&G Princeton Applied Research, EG&G Instruments and EG&G Signal Recovery. Declaration of Conformity...
  • Page 3: Table Of Contents

    3.1.01 Power Switch ............................. 3-1 3.1.02 Inputs..............................3-1 3.1.03 Sensitivity Switch..........................3-1 3.1.04 Outputs .............................. 3-1 3.2 Operating the Model 5182........................... 3-2 3.2.01 Introduction............................3-2 3.2.02 Signal Voltage and Gain ........................3-2 3.3 Battery Operation............................3-2 3.4 External Supply Operation .......................... 3-3...
  • Page 4 TABLE OF CONTENTS...
  • Page 5: Description

    Chapter 1.1 Description The 5182 is a current input preamplifier designed for use whenever the signal source is a current source - for example, with electron multipliers, ion collectors, photo multipliers and photo diodes. The sensitivity is switch selectable with five settings...
  • Page 6: Options

    Chapter 1, DESCRIPTION 1.2 Options The model 5182 is supplied complete with four 9 V alkaline batteries. The following optional extras are available. Model PS0108 Remote Line Power Supply for the model 5182. See Appendix B for details of this unit.
  • Page 7: Introduction

    2.1 Introduction The following procedure is provided to facilitate initial performance checking of the Model 5182. In general, the procedure should be performed after inspecting the instrument for shipping damage (any noted to be reported to the carrier and to PerkinElmer Signal Recovery), but before using it experimentally.
  • Page 8 5) Monitor the output; the output level should be 1 V pk-pk. 6) Set the signal generator to 1 kHz, 1 V pk-pk. Then set the 5182 AC sensitivity to A/V and monitor the output; the output level should be 1 V pk-pk.
  • Page 9: Introduction

    Chapter 3.1 Introduction The Model 5182 has been designed to be extremely easy to setup and use. It can be powered from an external source or from internal alkaline cells as selected from a front-panel switch. In operation, the signal to be measured is to the input BNC connector.
  • Page 10: Operating The Model 5182

    3.3 Battery Operation In battery powered operation, the 5182 requires four 9 V alkaline cells (type NEDA 1604, PP3 or equivalent). Each battery fits into its own removable tray accessible from the rear panel. When they are exhausted, all four batteries should be replaced together.
  • Page 11: External Supply Operation

    Appendix B) providing ±18 V DC, or the Preamplifier Power Output of most PerkinElmer Instruments lock-in amplifiers which provide ±15 V DC. Connection is by a DIN 5-way socket on the rear panel of the 5182. Figure 3-2, External Power Input Connector Pinout...
  • Page 12 Chapter 3, OPERATING INSTRUCTIONS...
  • Page 13: Appendix A, Specifications

    Specifications Appendix General DC coupled current to voltage amplifier with adjustable sensitivity and a maximum frequency response extending from DC to 1 MHz. Single-ended virtual ground input and single-ended DC and AC coupled outputs via BNC connectors. Battery powered from internal alkaline batteries or external DC power supplies. Inputs Mode Single-ended virtual ground...
  • Page 14 Appendix A, SPECIFICATIONS Frequency Response lower limit 0.5 Hz, (AC Output) upper limit depends on sensitivity setting, see Figure A-2 Figure A-2, Frequency Response Max DC current at input see Table A-1 Outputs AC Output 450 Ω Impedance Max voltage swing >...
  • Page 15: Power Supply Unit

    Power Supply Unit (Model PS0108) Appendix Figure B-1, Model PS0108 External Power Supply Fuse Rating 115 V operation 200 mA 230 V operation 100 mA 5 mm × 20 mm, 250 V, Slow Blow Fuse Type...
  • Page 16 Appendix B, POWER SUPPLY UNIT (MODEL PS0108)
  • Page 17 WARRANTY PerkinElmer Instruments Corporation warrants each instrument of its own manufacture to be free of defects in material and workmanship for a period of ONE year from the date of delivery to the original purchaser. Obligations under this Warranty shall be limited to replacing, repairing or giving credit for the purchase, at our option, of any instruments returned, shipment prepaid, to our Service Department for that purpose, provided prior authorization for such return has been given by an authorized representative of PerkinElmer Instruments Corporation.