LOCATION MOUNTING GUIDELINES:

• The sensor should be permanently mounted in a corner or on a
flat wall that is free of vibrations, at a height of 6.5 feet, using the
built-in angle mount.
• Mount the sensor on an insulated exterior wall facing in.
• Position the sensor to protect an area where an intruder is most
likely to walk across the detection pattern.
• Position the sensor so it faces a solid reference point, such as a
wall.
Outside walls
pointed away from
windows are great
locations
Avoid
HVAC
ducts &
drapes
X
Reproduction without permission is not permitted.

PRODUCT FEATURES

• Advanced circuit technology
resulting in ultra-low power
consumption
• 40 lb. Pet immunity
• Tamper detection/reporting

TECHNICAL SPECIFICATIONS

• Wireless signal range: 600 ft, open air
• Code outputs: paring, tamper, tamper restore, alarm detect motion,
alarm restore, supervisory, low battery
• Transmitter frequency: 319.5MHZ +-15KHz
• Transmitter bandwidth: 24KHZ
• Modulation type: ASK-OOK
• RF output power 91.1dBuV +/- 5% at 3m
• Sensor Range 30 ft x 40 ft
• Maximum Horizontal Sensing Angle 80°
• Replace batteries every 5 years with AAA Alkaline (x2)
• Sensor: 3.4H x 2.4W x 1.5D in.
• If possible, mount the sensor within 100 ft of the panel. While
the transmitter may have a range of 600 ft or more out in the
open, the environment at the installation site can have a
significant effect on transmitter range. Verify actual transmitter
range for each installation.
• Close all windows in an area with an armed motion sensor.
Avoid placement
looking at ceiling
fans
X
Qolsys Inc. proprietary.
• Rigid wall mounting for discreet
placement
• Easy to install batteries
• Supervisory health messaging
DO NOT:
• Aim the sensor at windows, fireplaces,
air conditioners, area heaters, forced
air heating vents or drapes.
• Place the sensor in direct sunlight as
Install at
sudden changes in temperature may
6.5' high
trigger a false alarm.
• Mount the sensor near duct work or
X
other large metallic surfaces that may
affect the RF signals.
• Set the sensor on a shelf.
• Mount outdoors or in a non-
temperature controlled environment.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IQ Motion QS1200-P01 and is the answer not in the manual?

Questions and answers

Summary of Contents for QOLSYS IQ Motion QS1200-P01

  • Page 1 • Mount the sensor near duct work or ducts & other large metallic surfaces that may drapes affect the RF signals. • Set the sensor on a shelf. • Mount outdoors or in a non- temperature controlled environment. Qolsys Inc. proprietary. Reproduction without permission is not permitted.
  • Page 2 (see detection pattern on page 3 of this manual). The detector should not be looking directly at stairs that would allow a pet to walk up them when the panel is armed. Qolsys Inc. proprietary. Reproduction without permission is not permitted.
  • Page 3 IC: 11205A-QS1200 Qolsys Part #: QS1200-P01 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Table of Contents