b&c data system EzW User Manual page 33

Magstripe reader writer
Table of Contents

Advertisement

Command: Select Track 2 BPI
Command code: <ESC> b [Density]
Hex code: 1B 62 [D2 or 4B]
Response: <ESC> 0 [1B] [30] select ok
<ESC> A [1B] [41] select fail
Description: This command is used to select the density of TK 2.
TK2 BPI=75
Command: Select Track 1 BPI
Command code: <ESC> f [Density]
Hex code: 1B 66 [D2 or 4B]
Response: <ESC> 0 [1B] [30] select ok
<ESC> A [1B] [41] select fail
Description: This command is used to select the density of TK 1.
TK1 BPI=75
Command: Select Track 3 BPI
Command code: <ESC> g [Density]
Hex code: 1B 67 [D2 or 4B]
Response: <ESC> 0 [1B] [30] select ok
<ESC> A [1B] [41] select fail
Description: This command is used to select the density of TK 3.
TK3 BPI=75
Command: Read raw data
Command code: <ESC> m
Hex code: 1B 6D
Response: [Raw Data Block] <ESC> [status byte]
Description: This command requests the EzWriter to read a card swipe but send without
ASCII decode. Refer to [Raw Data Block] & [Raw Data] Format.
Command: Write raw data
Command code: <ESC> n [Raw Data Block]
Hex code: 1B 6E [Raw Data Block]
Response: <ESC> [status byte]
Description: This command requests the EzWriter to write raw data block into the card
swiped. Refer to [Raw Data Block] & [Raw Data] format.
Command: Get device model
Command code: <ESC> t
Hex code: 1B 74
Response: <ESC> [Model] S
Description: This command used to get device model number compatible with IDT3840.
[Model] 1
Track 2
3
Track 1, 2, 3
5
Track 1, 2
B & C Data Systems * (541) 601-8282 * http://bcdata.com
33 of 42
[D2]: TK2 BPI=210 [4B]:
[D2]: TK1 BPI=210 [4B]:
[D2]: TK3 BPI=210 [4B]: