● CV
○ OUT1 ​ a nd ​ O UT2
■ VOLT​ s per octave - can be set anywhere from 0.01 to 2.00, or to HZPV
(Hz per volt)
■ TRAN​ s pose - pitch adjustment in semitones, with cent adjustment
● GATE
○ OUT1 ​ t o ​ O UT4 ​ - sets the gate output as either VTRIg or STRIg. Outputs 3 and 4
each have an additional special option of RUN and CLOCk respectively. See the
chapter on ​
○ OFFT​ i me - the minimum amount of time, in milliseconds, that a gate output will
switch off between consecutive notes. Most analog synthesizers with a gate or
trigger input should be happy with the minimum, 0.1, but some may require a
higher value
● TCLO​ (trigger clock)
○ IN​ p ut
■ PPQN ​ - pulses per quarter-note
■ AUTO​ - start - whether the presence or absence of a trigger clock signal
should start and stop playback automatically
○ OUT​ p ut
■ PPQN ​ - pulses per quarter-note
● MIDI
○ CLOC​ k
■ OUT ​ ( MIDI beat clock output) - ON or OFF
■ MAGN ​ ( tempo magnitude matching) - ON or OFF
○ THRU ​ - MIDI thru, ON or OFF
○ CMD ​ - global MIDI commands - see ​
■ PLAY​ / stop playback
■ REST​ a rt playback, if already playing
■ REC​ o rd
■ TAP ​ t empo
● SWIN​ g interval - sets the timing interval to which swing may be applied. By default this is
set to 16th-notes. Unlike all of the other ​ s ettings menu ​ settings, this is specific to a song
and is saved with it. Loading a song recalls its swing interval setting, and creating a new
song reverts to the default
● QUAN​ t ization - the level at which recorded notes are quantized. May be set to an
interval such as 16-notes, or set to OFF (which will in fact quantize to 192nd-notes), or to
"ZOOM", which will quantize to your current ​
● CURS​ o r - controls the appearance of the play-cursor - FAST (short and sharp blinks),
SLOW (solid white squares), or OFF
● MONI​ t oring - sets the monitoring mode for recording samples: ON, OFF, or SMARt
● FIRM​ w are - not a "setting" per se, but will tell you the firmware's version number
C V / gate​
for more details
s pecial instructions
z oom level