2 | MAXPRO
NVR PE Quick Install Guide
5. Honeywell IP Camera Configuration
Using the MAXPRO NVR Wizard (3 Clicks to Live Video)
The setup wizard starts automatically after you log on (this can take up to
two minutes).
1.
The CONFIGURATION dialog appears. When the network is ready
(
or
appears in the notification area), click
the default settings and proceed to CAMERA DISCOVERY.
To modify the settings for your unique system requirements, refer to
the table below. (After initial setup, you can do this in the MAXPRO
NVR client.)
Field
Description
Video Format
NTSC, PAL
Start Recording
Start recording as soon as the camera is
added in MAXPRO NVR.
Dynamic IP
NVR synchronizes any change in a
Synchronization
device's IP address.
Auto Add
Any newly connected device is
Discovered Camera
automatically added to the Devices list.
Choose Camera
Choose your camera's network.
Network
Auto IP Assignment
Assigns a valid static IP address to the
camera. Use only if you do not have a
DHCP server and you want to assign an
IP address in your computer network
range.
Filter Discovered
Filter the discovered cameras based on
Cameras
the camera model and/or IP range.
Click
to reset the values without saving any changes.
2.
The CAMERA DISCOVERY window appears. Each newly connected
camera is identified and an IP address is assigned to the camera by
the Wizard, after which the camera reboots.
It may take a few minutes before the cameras are discovered and
Discovery in progress...
added. You will see a
to a pop-up message on the lower right of your monitor. The list
disappears as the cameras are added to the MAXPRO NVR.
Click
only after all connected cameras are discovered and
added.
Click
to return to the CONFIGURATION page.
3.
The INSTALLATION window appears. Click
MAXPRO NVR application (see 3 Live View).
Note
To add non-Honeywell devices, see

6. Live View

Log On to the MAXPRO NVR Viewer
1.
When you click
in the Setup Wizard, the Log On dialog box
appears. Please wait while the system logs you on automatically as a
Windows Logged-In User.
2.
MAXPRO NVR launches and the Viewer tab appears (see below). The
Devices area in the left pane lists all of the discovered network
cameras.
View Live Video
To view video from cameras, double-click MAXPRO NVR in the Devices list
to display video from all discovered cameras in the Viewer. You can also
highlight and drag each camera into a panel.
Note
For continuous monitoring of live video, it is recommended that you use a remote client workstation.
To install a remote client, use the installation software on the software and documentation DVD
included with your unit. Select Client Installation as the Installation Type during setup. For more
details, refer to the MAXPRO® NVR Commissioning and Installation Guide.
List of Honeywell IP cameras connected
to and discovered by MAXPRO NVR.
Devices tab: Currently active.
Alarms tab: Acknowledge and clear alarms.
Images/Clips: select images
and clips to view.
Double-click or drag the clip
to a Viewer panel to view.
To export a clip for forensics,
click the arrow
to switch to Full Timeline
mode, then click the Clip
Export icon.
Timeline
User currently
logged on
© 2013 Honeywell International Inc. All rights reserved. No part of this publication may be reproduced by any means without written
permission from Honeywell. The information in this publication is believed to be accurate in all respects. However, Honeywell cannot
assume responsibility for any consequences resulting from the use thereof. The information contained herein is subject to change
without notice. Revisions or new editions to this publication may be issued to incorporate such changes.
STEP 1: CONFIGURATION
to accept
STEP 2: CAMERA DISCOVERY
Pop-up
message
indicator in addition
STEP 3: INSTALLATION
to start the
7. Third-Party Device
Configuration.
Change
Play in
Time jump control to
Play
playing speed
reverse Pause
quickly locate video
forward
7. Third-Party Device Configuration
Non-Honeywell devices are configured using the MAXPRO NVR software. To set up cameras for video input:
1.
Launch MAXPRO NVR.
2.
On the Configurator tab, click the
Camera tab.
3.
In the Discover cameras here
area, click
connected cameras in the subnet.
4.
Click
Camera list and ensure that the
user name and password in the
Advanced Discovery Settings
match the user name and
password of the camera.
5.
To change the default parameters
of a camera, select the camera,
and then click
Web View For Advanced Set Up
to open the camera advanced
settings pane where you can
modify the settings as required.
6.
Click Save for your new settings
to take effect.
Note
For detailed information on adding and configuring third party cameras that do not support automatic discovery,
please refer to the MAXPRO NVR 2.5 Operator's Guide.

8. Advanced Features

Note
For more detailed information on the advanced features available in MAXPRO NVR PE, please refer to the
comprehensive guides available in the UserManuals folder on the software and documentation DVD.
Configurator Tab
Configurator tab consists of seven sub-tabs: System, Disk, Camera, Schedule, I/O, Sequence, User.
Search Tab
1.
Select the check box next to the camera(s) from which the video was recorded.
2.
Select search conditions in the Date time filter, and then click Search (
9. MAXPRO NVR Default IP Addresses
Your MAXPRO NVR unit has one or two configured network ports with the following default IP addresses:
192.168.1.101 for LAN1 (Camera Network)
172.25.254.101 for LAN2 (Client Workstation Network) * Not available on some units.
If more than one MAXPRO NVR unit is on the same network, it is recommended that you assign a unique IP address and
computer name to each unit (the default name is MAXPRO-NVR).
To change the IP address
1.
Click the network icon (
Sharing Center, and then click Change adapter settings.
2.
Right-click Camera Network or Client Workstation Network, and then click Properties.
3.
Click Internet Protocol Version 4 (TCP/IPv4), and then click Properties.
4.
Click Use the following IP address, and then, in the IP address, Subnet mask, and Default gateway boxes, type the
IP address settings.
5.
Click Use the following DNS server addresses, and then, in the Preferred DNS server and Alternate DNS server
boxes, type the addresses of the primary and secondary DNS servers.
To change the computer name
1.
Click Start, right-click Computer, click Properties, click Advanced system settings, click the Computer Name tab,
and then click Change...
2.
Under Computer name, delete the old computer name, type a new computer name, and then click OK. The name
cannot contain spaces or all numbers or any of the following characters: < > ; : " * + = \ | ?. After changing the
computer name, restart the computer.
3.
Navigate to the C:\Program Files\Honeywell\MaxproNVR\TrinityFramework\bin folder, and then double-click
MaxProNVRMachineNameUtility.exe to open the Maxpro NVR Utility.
4.
The new computer name should automatically appear in the Machine Name field. If it does not, enter the name
manually. Click Update. The message

More Information

MAXPRO NVR PE
Please refer to the appropriate user guide located on the
software/documentation DVD or on the Honeywell
product web site at
www.honeywellvideo.com.
Select date and time
to start recording
Number
of alarms
detected
2.
to discover the
to add the device to the
next to Launch
Use the Configurator tab to configure video devices and set up your MAXPRO NVR PE system. The
Configurator tab sub-tabs:
System: Recording, email, holiday/exceptions for
schedules.
Disk: Configure and monitor video storage hard drives.
Camera: Discover and add network cameras, live camera
configuration, recording, video motion detection.
Schedule: Set recording schedules for recorded video.
I/O: Configure input and output for each camera.
Sequence: Select a sequence of cameras for live video.
User: Set user access and permission levels.
Use the Search tab to search for recorded video (clips) or events.
or
) in the located next to the clock (lower right of screen), click Open Network and
Machine Name Updated Successfully
Third Party Devices
A comprehensive list of all the third party devices
supported by MAXPRO NVR is available at Honeywell
Open Technology Alliance (HOTA)
www.security.honeywell.com/hota/.
www.honeywellvideo.com
+1.800.323.4576 (North America only)
https://honeywellsystems.com/ss/techsupp/index.html
Document 800-12139V1 – Rev B – 05/2013
4.
3.
5.
6.
).
appears when the update is complete.

Advertisement

loading