DECLARATIONS OF
CONFORMITY
We, Veracity UK Ltd, of Prestwick International
This device complies with Part 15 of the FCC Rules.
Aerospace Park, 4 Dow Road, Prestwick, KA9 2TU,
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this
UK declare under our sole responsibility that the
device must accept any interference received, including
product:
interference that may cause undesired operation.
VHW-HWPS-C2
HIGHWIRE Powerstar Duo
NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
is in conformity with the essential requirements
against harmful interference when the equipment is operated
and other relevant requirements of the EMC
in a commercial environment.
Directive (2014/30/EU)
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction
The products are in conformity with the following
manual, may cause harmful interference to radio communications.
standards:
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
EN 55022:2010
interference at his own expense.
EN 55024:2010
Responsible person:
Alastair McLeod, Group CEO
Issued:
7th Dec 2015, Prestwick,
© Veracity UK Ltd 2016 QSGWV1.4 UK
HIGHWIRE POWERSTAR DUO is a trademark of Veracity UK Ltd
CONNECTIONS & LEDS
CONNECTIONS & LEDS
RJ45 Ethernet 10/100Base-Tx
LED
and POE connectors (auto speed,
COAX LINK
duplex, crossover, POE/POE Plus)
COAX NET
LED
FUNCTION
On = link
RJ45 Yellow
COAX PWR
Blink = activity
(Power)
POE POWER
RJ45 Green
On = POE detected
BUDGET
and enabled
BNC Connector (for connection to any 75ohm
coaxial cable)
Power Connector Optional (Connect to a Veracity
57V power supply only - in polarity shown)
FUNCTION
GREEN
ORANGE
Coax data
Blink = no link
Loss of data
connection
On = 100Mbps
Base side network
On = link
n/a
connection
Blink = activity
POE over coax
On = enabled
n/a
status
by Base unit
Total camera
On = available
Approaching
power budget
5W blink = <5W
power limit
VHW-HWPS-C2
QUICK START GUIDE
RED
2 PORT ETHERNET OVER COAX ADAPTOR
Severe
Loss of data
10Base-T
(not supported)
Blink = error code
Power limit
exceeded
Need help?
Do you have a question about the HIGHWIRE Powerstar Duo VHW-HWPS-C2 and is the answer not in the manual?
Questions and answers