Armada PRO-90 Instruction Card

Clamp multimeter

Advertisement

Quick Links

PRO-90
Instruction
Clamp Multimeter
Card
Warning
Safety
. . . . . . . . . .
. . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . . .
Read First
Safety Information
To ensure safe operation and service of
the Tester, follow these instructions.
Failure to observe warnings can result in
severe injury or death.
- Avoid working alone so assistance can
be rendered.
- Do not use test leads or the Tester if
they look damaged.
- Do not use the Tester if the Tester is
not operating properly or if it is wet.
- Use the Tester only as specified in the
Instruction card or the protection by
the Tester might be impaired.
- Use extreme caution when working
around bare conductors or bus bar.
Contact with the conductor could
result in electric shock.
- Do not use the Tester to measure volt-
ages in circuits that could be damaged
by the Tester's low input impedance
(approximate 4KΩ)
- Use caution with voltages above 30 V
ac rms, or 60 V dc. These voltages
pose a shock hazard.
Symbols as marked on the Tester
and Instruction card
Risk of electric shock
See instruction card
DC measurement
Equipment protected by double or
reinforced insulation
<
Battery
Earth
AC measurement
Conforms to EU directives
Application around and removal
E
from hazardous live conductors is
permitted
Do not discard this product or
throw away

Power On / Off

The Meter displays Battery Capacity
when powering up. Please replace the
battery when 0% is shown.
Caution
The Tester powers up in Ω / continuity
mode.
Disable
Auto Hold Enable /
Disable

Self-Testing Aid

Fail of usage
Ready to use
Do not measure while powering up, it
will cause Self-Testing failure.
Caution
Do not use the Meter when "FAIL" is
shown. Undiscovered failure could exist
even No "FAIL" is shown.
ACA
 CAT.Ⅲ.600V
with respect to
earth for the jaw.
Barrier for
Hand Guard
 Do not hold
the meter above
the Barrier

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRO-90 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Armada PRO-90

  • Page 1  Read First Fail of usage  Safety Information To ensure safe operation and service of the Tester, follow these instructions. PRO-90 Instruction Failure to observe warnings can result in severe injury or death. Ready to use Clamp Multimeter Card - Avoid working alone so assistance can •...
  • Page 2: Data Hold

    AC V / DC V Continuity Priority of function Data Hold Beep Guard The internal sounder will beep continu-  The LCD display shows Caution ously with LCD display flashing in two voltage mode when the situations in the Data Hold mode: input Terminal is When connecting the test leads to the satisfied by the following...
  • Page 3: Specifications

    400Ω. Specified from 0°C ~ 40°C. Ⅲ The building installation. The source of the Low-voltage Ⅳ AC Current installation. Armada Technologies Function Range Accuracy Conductor Size : 27mm diameter. Pollution degree : 2 3596 76th St. SE  Caution 0.9A ~ 600.0A ±(1.9% + 5 dgt)*...

Table of Contents