RITS-N IRM203-UNI User Manual

RITS-N IRM203-UNI User Manual

Advertisement

Quick Links

IRM203-UNI

User Manual

. 1
D
e
c s
i r
t p
o i
n
Cover
Menu button
Connector
Change settings button
Menu display
IR angle adjustment screw
Set (Apply) button
IR angle scale
Radar sensor unit
Indicator LED
Radar sensitivity
volume
(Green/Red/Blue)
IR sensitivity
Settings display
IR sensor
IR detection area
volume
unit
adjustment

4. Mounting Precautions

Mounting height of
Mount within 50mm of
Ensure that there are
3m (9.8 ft) or
the bottom of the door
no moving objects in
lower.
engine cover.
the detection area.
3m
(9.8ft )
Make sure that the
Ensure the minimum
If possible, ensure there is
sensor is not directly
of reflected sunlight
no accumulation of snow
exposed to heavy
from the floor.
or water on the floor.
rainfall.
Infrared detection area setting to maximise pedestrian safety.
A
A
B
Moving door leaf
Moving door leaf
B
Side view
Plan view
6. Mounting & Wiring Information
① Attach the mounting template so that it is
Drill screw (mounting) (Ø3.5mm)
placed within a 50mm distance from the
and power cable (wiring) (Ø10mm)
bottom edge of the door engine cover.
holes.
Max 50mm
Max 50mm
④ Controller wiring
Red
Power (AC/DC 12V~24V)
Black
White
Activation Output
Green
Yellow
Safety output
Blue
Gray
Test Input + (DC 12~24V)
Test Input -
Brown
⑥ Connect the power connector.
⑦ Attach the cover.
Cable Length(Min) 80mm
. 2
E
x
e t
i r
r o
i D
m
e
n
s
o i
n
s
Accessories
Mounting
template
265

3. LED Indicators

User Manual
Green
Cable 2.5m
Blue
LED Indicators
Red
Mounting screws
IRM203-UNI
Ensure that no
Infrared & Radar sensor detection
condensation gets
onto the sensor.
AC
DC
12~24V
(
),
(
)
~
AC12V: 300[mA] (Max) / AC24V: 200[mA] (Max)
Power consumption
DC12V: 160[mA] (Max) / DC24V: 80[mA] (Max)
Use different frequency
Test input
6[mA] @ 24[VDC]
settings for sensors
Weight
250[g]
in close proximity.
Color
Black
1
2
-20 ~ 50[
°C]
The Radar sensor unit
0.5 seconds
may be negatively affected
by metal close to or
in the detection area.
③ Use a flathead screwdriver to remove cover.
⑤ Attach the sensor to the door
⑧ How to remove the cover after installation
1. Insert a flathead screwdriver as shown
2. Turn the screwdriver counterclockwise gently to prise the cover from the sensor body
Infrared presence
timer setting
60
42.5
Unit : mm
Frequency
Standby
Setting
Radar detection
Safety Relay
Output
IR or IR+Radar detection
Radar unit
direction
detection
Activation
Relay Output
±10 [%] @ 50/60[Hz]
Activation
Relay
Output
Configuration
TEST Input
Low reflection
setting
Factory
reset

8. Detection

IR detection area depth adjustment
Screw
WARNING
Near
DO NOT use any
Removing/assembling the Radar Sensor Detection Module
flat head screws.
1.
Twist with your index finger
in the indicated direction.
2.
Hold and pull forward the upper part of the
module with your index finger.
IR detection area width adjustment
[ Near ]
[ Far ]
1.0[m]
-0.5
1.0[m]
-0.5
1.0[m]
-0.5
0
0
0
-8 Angle setting
+4 Angle setting
1.0
1.0
Narrow
Door
Door
2.0
2.0
2.2
2.2
3.0
3.0
Wide
3
2
1
row row
row
row
row
Far
※Ensure that detection setting does not exceed the door.
Radar detection area adjustment
3.
After removing the module, turn 90 degrees
clockwise, and re-assemble.
90°
m
2 sec
30 sec
60 sec
O
N
C
N
U
i n
i B
O
N
C
N
+
+
+
+
without TEST
With TEST
without TEST
without TEST
With TEST
without TEST
0
. 2
[ 0
m
]
1.0
1.0
2
0 .
1.0
2.0
2.2
3.0
Narrow
Wide
(Installed height: 2.2 m)
(Default Sensitivity)
detection module
detection module
vertical angle
vertical angle
:
3 Step(15°)
S3
:
3 Step(15°)
S3
:
6 Step(30°)
S6
:
6 Step(30°)
S6
:
9 Step(45°)
S9
:
9 Step(45°)
S9
m
m
m

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IRM203-UNI and is the answer not in the manual?

Questions and answers

Summary of Contents for RITS-N IRM203-UNI

  • Page 1: User Manual

    IRM203-UNI User Manual Infrared presence 2 sec 30 sec 60 sec timer setting Cover Accessories 42.5 Mounting template Menu button Unit : mm Connector Change settings button Menu display IR angle adjustment screw 3. LED Indicators Set (Apply) button User Manual...
  • Page 2 11. Troubleshooting 9. Operation check Problem LED Status Possible Causes Troubleshooting Measures Radar After completing installation, walk into the detection area of the sensor. If you feel that the detection sensitivity volume area is incorrect, then adjust it as per section 8. The infrared spot finder SF100 is recommended to Insert the sensor accurately set the infrared detection area.The IR sensitivity volume can also be increased/ Loose connector...

Table of Contents