REL HT/1205 Operating Instructions Manual

REL HT/1205 Operating Instructions Manual

Ht series, sub-bass system
Hide thumbs Also See for HT/1205:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for REL HT/1205

  • Page 3 Operating Instructions for the SerieHT Sub-Bass System...
  • Page 5 Caution Marking Explanation The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of un-insulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
  • Page 6 Important Safety Instructions 1 Read all of these instructions. 2 Save these instructions for future use. 3 Heed all warnings. 4 Follow all instructions. 5 Do not use this apparatus near water. 6 Clean only with damp cloth. 7 Install in accordance with the manufacturer’s instructions. 8 Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.
  • Page 7 15 Minimum distances 10cm around the apparatus for sufficient ventilation. 16 The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, curtains, etc. 17 No naked flame sources, such as lighted candles, should be placed on the apparatus. 18 Attention should be drawn to the environmental aspects of battery disposal.
  • Page 8 Attention Explication Marquage L’éclair avec le symbole de pointe de flèche dans un triangle équilatéral est destiné à alerter l’ utilisateur de la présence de non isolée tension dangereuse à l’intérieur de l’enceinte du produit qui peut être d’une ampleur suffisante pour constituer un risque d’électrocution pour les personnes.
  • Page 9 9 Ne pas contourner le dispositif de sécurité de la prise de terre. Une fiche de terre a deux lames et une troisième broche de mise à la terre. La troisième broche est fournie pour votre sécurité. Si la fiche fournie ne rentre pas dans votre prise, consultez un électricien pour le remplacement de la prise obsolète.
  • Page 10 Avertissement Cet article est lourd. Pour éviter tout risque de blessure, prendre soin lors de la manipulation. L’ appareil ne doit pas être exposé à des éclaboussures et aucun objet rempli de liquide, comme des vases, ne doit être placé sur l’appareil. Les conduites Plus est utilisé...
  • Page 11 2- channel system. We believe HT will open up the world of REL to a large body of enthusiasts, old and new, and in doing so deliver the magical world of theater sound in a uniquely REL way.
  • Page 12 (For home cinema use, use .1/LFE input) 7 RCA Output: Used to connect or “daisy chain” another REL in tandem. 8 Power On/Off Switch: Use to turn unit on or off.
  • Page 14 Phase Switch The phase control on a REL has two positions, 0 and 180. One of these positions will set the REL in phase with the speakers, and one will set it out of phase. The labels 0 and 180 are just labels and tell us nothing about the rest of the system, only if the REL is working with the speakers or not.
  • Page 15 REL Set-Up Made Simple With the REL SerieHT, there are two basic ways to connect and setup. The first is a single channel input from the sub out of a theater or power speaker system. In this case a single RCA cable is need and the CROSSIVER control can be set to LFE since the source will have an internal upper frequency limit.
  • Page 16 50Hz on the crossover control, or slightly higher for smaller speakers. At this point turn the HI/LO LEVEL control up so that both the REL and speaker are roughly equal in volume and then switch, using the phase switch, from “0” to “180” phase positions. Again, whichever position is loudest or fullest is the correct position.
  • Page 17 To determine the crossover point, take the volume of the REL (using the Level control) all the way down, and put the crossover to 10 o’clock. At this point, bring the REL’s volume back up slowly to the point where you have achieved a subtle balance, i.e.
  • Page 18 This belief allows SerieHT to achieve the highest possible level of fidelity. Overload Protection All REL Sub-Bass Systems are designed as true sub bass speakers. They are designed to reproduce those exceptionally deep notes that are felt as well as heard. This it will attempt to do at whatever volume level you set.
  • Page 19 All REL sub bass system designs utilize a true Power On-Off switch that affords the owner the ability to turn off their unit completely, without having to unplug the A/C mains cord. When a REL sub bass system is switched off using the Power On-Off switch on the rear panel it draws ZERO power.
  • Page 20 HT/1205 Specifications Type: Closed box, front firing woofer Drive Unit: 12 in., Glass fiber reinforced cone with inverted dust cap In Room Lower Frequency Response: -6dB at 22Hz Input Connectors: Low Level stereo RCA, LFE RCA Output Connectors: Low Level stereo RCA, LFE RCA...
  • Page 21 12.5 x 13.7 x 13.8 in., (318 x 347 x 351 mm) Net Weight: 33.3 lbs. (15.1 kg) Finish: Vinyl Supplied Accessories Mains Lead: Users Setup guide: In the interest of product development, REL Acoustics Limited reserve the right to vary these specifications without notice...
  • Page 22 Notes...