Ontech GSM 9040 Reference Manual
Hide thumbs Also See for GSM 9040:
Table of Contents

Advertisement

Ontech GSM 9040/50
Reference Manual
English
-1 -

Advertisement

Table of Contents
loading

Summary of Contents for Ontech GSM 9040

  • Page 1 Ontech GSM 9040/50 Reference Manual English -1 -...
  • Page 2: Table Of Contents

    Disclaimer ............................5 Overview ............................. 6 Accessories ............................6 External temperature sensor 9901 ..................... 7 Ontech IR Eye 9016 ..........................7 Get started ........................... 8 Content in the package ........................8 Start up the unit the first time ......................8 SIM-card ............................
  • Page 3 Power fail alarms ..........................21 IR controller for air pumps ......................22 Mount and connect the IR Eye 9016 to Ontech GSM 9040 .............. 22 Set the air pump brand ........................22 Testing and controlling your air pump ....................23 Other functions ..........................
  • Page 4 Technical specifications ......................30 Support ............................30 QR codes ............................ 30 -4 -...
  • Page 5: Welcome

    Welcome Thank you for chosen Ontech GSM 9040/50. We hope you will be satisfied with the product and that it will be a good help for you. This manual covers all you have to know about the product. If you want a more comprehensive manual, we recommend the “Quick Start Guide”...
  • Page 6: Overview

    (see below). These products connected is used to remote control air pumps for cooling and heating with the Ontech app. It is like you have your IR Remote Control for the air pump in you smartphone instead of the physical remote control. All major manufacturer of air pumps are supported.
  • Page 7: External Temperature Sensor 9901

    The Ontech IR Eye 9016 is a small IR transmitter connected with a 1,5 meter long cord to Ontech GSM 9040. It is mounted on the wall in the same room as the air pump. Then the air pump can be controlled from the Ontech apps for Android or Iphone.
  • Page 8: Get Started

    Prepaid SIM-cards can be used. Have in mind that it is only valid for a certain period of time if it is not used and not refilled. It can also use up all money and then the Ontech GSM 9040 cannot send any message or alarm.
  • Page 9: Change Password

    1. Send an SMS to the unit with the following message: 1234#8*8*5678# (1234= old Password, 4567 =new Password) 2. Do not forget to change the Password in the Android or Iphone app if you use such to operate your Ontech GSM 9040. -9 -...
  • Page 10: Using Apps

    In the Android app the functions are integrated and the user does not see the SMS sent or received. All settings are also handled in the app. The Android app can also control up to five different Ontech GSM units.
  • Page 11: Installation And Setting Of The Android App

    When all settings are done you will return to the Main Page by click Android general Back-button. You are now done with the settings and the app is ready to use to control your Ontech GSM 9040. Installation and setting of the Android app...
  • Page 12: Functions

    Functions Ontech GSM 9040 is a product with many functions. Below is a list of all functions. Name Description - Air pump This functions demands an Ontech IR Eye 9016 product (buy optional). With this function you can control your air pump heater/cooler from anywhere with the Ontech App for Android or Iphone.
  • Page 13 The short range radio communicates with the optional devices Ontech Relay and Ontech Alarmbox. It can be set to different radio channels (frequencies). Channel 0-15 can be set. It is important that all units in the system is set to the same channel.
  • Page 14: Set Functions

    3. Press the button SIM settings. An alert panel appears. Select Ontech GSM 9025 or 9035. 4. A website named Setting your Ontech Unit opens in the web browser Safari. Tilt the Iphone to landscape screen position in order to make the text more easily read.
  • Page 15: Set The Functions With A Smartphone

    1. Launch the telephones web browser. Go to the page http://www.ontechgsm.com/set.html. 2. A website named Setting your Ontech Unit opens in the web browser Safari. Tilt the Iphone to landscape screen position in order to make the text more easily read.
  • Page 16: Control The Unit

    Turn on or off the 230 V outlet on the main unit and/or one or more of the extra units Ontech Relay 9010 if you have such connected to the system. Press on the unit name and select Relay ON or Relay OFF. With Set relay can set the time you want the 230 V outlet to be on and then turn off (timer function).
  • Page 17: Controlling With Sms

    Two or more commands can be written in the same SMS, just write them after each other and separate the commands with the sign #. Example: You want to turn on the relay in the main unit and turn off the 230 outlet of the Ontech Extra Relay with ID 3.
  • Page 18: Alarms

    1. Launch the telephones web browser. Open the page http://www.ontechgsm.com/set.html. 2. A website named Setting your Ontech Unit opens in the web browser Safari. Tilt the telephone to landscape screen position in order to make the text more easily read.
  • Page 19: Activate And Deactivate The Alarm Function

    Powerfail alarms cannot be acknowledged. Wired alarm sensors Different types of wired alarm sensors can be connected to Ontech GSM 9035. The unit has two alarm inputs. Default setting is Normally Open (NO). If the alarm sensors you connect are of the type Normally Closed (NC), you have to set this, see Functions on page 12.
  • Page 20: Delay Of Wired Alarms

    Figure 2 Two alarm sensors Normally Open Figure 3 Two alarm sensors Normally Closed Important! If the unit is set to Normally Closed function and only one alarm input is used, the other must be connected with a wire to the 3.8 V wire. If this is not done, the unit will interpret this as the circuit is open and thus send an alarm message.
  • Page 21: Temperature Alarm

    Temperature alarm Ontech GSM 9035 can be set to send an alarm message if the temperature rise above or decrease below the set temperature value. All temperature measurements and settings will use Celsius degree.
  • Page 22: Ir Controller For Air Pumps

    IR controller for air pumps This function will only work if an Ontech IR Eye 9016 is connected to Ontech GSM 9040. Ontech IR Eye 9016 is included in the Ontech IR Controller 9050 package.
  • Page 23: Testing And Controlling Your Air Pump

    Testing and controlling your air pump  Test the function by using the app for Iphone or Android (see Control the unit page 16) and send commands for temperature, mode and fan from the main page on the app.  If it is not working, check the position of the IR Eye 9016, maybe it is out of range.
  • Page 24: Other Functions

    16) or by pushing the button on the unit. Garage Opener function Important! Can only be operated from Android telephones with the Ontech Control app installed. With this function you can make the unit recognize up to three mobile numbers. When any of these numbers are calling the unit the 230 V outlet will turn on for one second and then turn off without answering the call.
  • Page 25: Add A User To The List

    Sensor Ontech GSM 9040 is prepared to measure current 4-20 mA or voltage 0-10 V and report the value back to user and can also be set for sending alarm messages at preset values.
  • Page 26: Others

    1*; 2; 3/21 Indicates which components there is in the system. ID1 is the main unit and will always appear. ID 2 in this example is an extra Relay Ontech Relay. 3/12 indicates an Ontech Alarmbox 9012 with ID3 is connected to the system and that its temperature is 21 degrees C.
  • Page 27: Master Functions

    This is the set thermostat temperature. Important! Under Units: is shown the extra units (Ontech Relay 9010, Ontech Relay 9015 and Ontech Alarmbox 9012) that is connected to the main unit with the short range radio. If these units loose contact with the main unit it can take up to one hour before this information is shown in the status SMS.
  • Page 28: Updating The Firmware

    Updating the firmware The latest version of the firmware for Ontech GSM 9040 can be downloaded from www.ontechgsm.com. The unit can be easily updated from a PC computer. Updating the firmware erases all settings in the memory of the unit. All settings including the Password has to be set again.
  • Page 29: Trouble Shooting Guide

    Wrong radio channel set Check all units in the system has connect to extra Short range radio disabled the same radio channel set. units Ontech Relay Check that the short range radio and Ontech Alarm function is turned on. The unit do no...
  • Page 30: Technical Specifications

    Compliance EMC, LVD and R&TTE directive Support If you have problems with your unit, contact the product support by email at support@ontechgsm.com or your local distributor or dealer. QR codes Ontech Control for Android Ontech Control for Iphone Settings for Smartphones -30 -...

This manual is also suitable for:

Gsm 9050

Table of Contents