Ethernet Write LED......... 11 Connectivity............. 11 3.6.1 MSView............11 3.6.2 LiveView Web Pages........12 3.6.3 Connecting to a LAN / WAN......13 3.6.4 Connecting to the EMC-1 from a Remote Location............14 Push-button Functions........15 3.7.1 Factory Reset........... 15 3.7.2 To Recover from a Failed Firmware...
• Morningstar LiveView Internet Web monitoring TS-MPPT-60* and Network settings changes; * The EMC-1 included Y-cable is required to draw power from • Monitoring, logging and custom programming the RJ-11 port while communicating via the RS-232 port. See using Morningstar MSView PC software;...
1.2 Features 2.0 INSTALLATION The features of the EMC-1 are shown in Figure 1-1 below. An explanation of each feature follows. 2.1 Mounting The EMC-1 can be wall-mounted, surface-mounted or DIN rail mounted using basic tools: Flat head screw driver...
Choose the DIN rail mounting location. It should be protected from direct sun, high temperatures, corrosive fumes, and water. Do not install the EMC-1 in a confined area where battery gases can accumulate. Step 2 Confirm sufficient space above and below the DIN rail...
2.5 Connecting the Power Wires 2.4 DIP Switch Set-Up The EMC-1 is powered from an 8-80 Vdc supply, such as an AC-DC converter or system battery connected Figure 2-2 below shows DIP switch locations and to the power input provided on the EMC-1 unit. See...
3.2 LED Indicators 3.0 OPERATION There are three EMC-1 LED indicators - see Figure 3-1 below - that will show all statuses of the EMC-1 - left 3.1 Start-up to right: Status LED (green / red); Web Service LED After the EMC-1 has been installed, as described in (green / red);...
2 secs establishing connection 3.6.2 LiveView Web Pages Solid green Connection made / broadcasting Using a Web browser, the EMC-1 allows access to a Solid red Cannot connect to server Morningstar Device’s LiveView Web pages via two Flashing red methods:...
Connectivity Manual - link below). System 3. Login to the network router, and choose a static IP The System Web Page is used to update EMC-1 address outside of the listed dynamic range. firmware. Connected device firmware cannot be updated through the System Web Page. The System 4.
• Stored non-volatile product data Table 4.1. Error Conditions To Perform a Factory Reset: Problem: 1) With the EMC-1 powered ON, press and hold the No valid Morningstar Devices found. push-button until the status LED (left) starts to flash Solution: R-G, R-G..
TWO (2) Verify good Ethernet cables and connections. years from the date of shipment to the original end user. Morningstar will, at its Verify that NetBIOS name or IP address is correctly option, repair or replace any such defective products.