Download Print this page

Rinnai Q175S Specifications

Condensing boiler

Advertisement

Quick Links

Standard Features

Onboard outdoor reset control system with sensor standard
Prebuilt plumbing kit with insulated Low Loss Header
Priority DHW standard (3 way valve not included)
Domestic hot water plate warming
Modulating Ceramic premix burner
5:1 turn down ratio
Spark ignition
Exceeds SCAQMD 1146.2 Low NO
Stainless Steel Water tube condensing heat exchanger
Direct Vent sealed combustion
Concentric and twin pipe venting adapters included
Approved for room and closet installations
SPECIFICATIONS
General Specifications
Water content
Max. supply boiler
temperature
Max operating pressure
Relief valve rating
Relief valve pressure rating
Dry weight
Min inlet gas pressure NG
Max inlet gas pressure NG
Min inlet gas pressure LP
Max inlet gas pressure LP
Max equivalent exhaust
vent length
Max equivalent combustion
air vent length
Approved venting materials
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
© 2011 Rinnai Corporation
requirements
x
Boiler
Boiler
Model
Model
Units
Q175S
Q205S
gal
1.8
1.8
°F
176
176
psi
45
45
MBH
375
375
psi
30
30
lbs
141
141
"W.C.
4.0"
4.0"
"W.C.
10.5"
10.5"
"W.C.
8.0"
8.0"
"W.C.
14.0"
14.0"
ft
80
40
ft
80
40
Polypropylene,
Stainless Steel,
PVC, CPVC
Q175S / Q205S Condensing Boiler

Optional Accessories

3 way valve DHW kit
RS100 Single zone controller
Flue Gas temperature sensor
Room Air Filter
NG to LP conversion Kit
LP to NG Conversion Kit
Performance Specifications
Fuel Type
Input
Heating Capacity
AFUE (I=B=R)
Part Load Efficiency
(EN677)
Electrical Specifications
Electrical Voltage Mains
Electrical Voltage Controls
Power Consumption Max
Load
Power Consumption Stand
by Load
Recommended Circuit
breaker rating
Q175S / Q205S SP
Boiler Model
Units
Q175S
Q205S
NG/LP
NG/LP
MBH
175
205
MBH
161
189
%
95.7
95.7
%
98.5
98.5
Boiler Model
Units
Q175S
Q205S
V/Hz
120/60
120/60
V
24
24
W
210
234
W
14
14
A
15
15
2/2011

Advertisement

loading

Summary of Contents for Rinnai Q175S

  • Page 1: Standard Features

    Max equivalent combustion air vent length Approved venting materials Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2011 Rinnai Corporation...