Download Print this page

Mars CashFlow 126 Quick Reference Manual page 2

Hide thumbs Also See for CashFlow 126:

Advertisement

What Is The Green
Doing?
LED
STATE
MEANING
ON
Power is
validator is O.K.
ON
1 x Flash
Reject lever pressed or coin accepted
2 x Flash
Coin rejected as unrecognised
3 x Flash
Coin inhibited by validator
4 x Flash
Coin inhibited by validator or machine
Flashing
Validator is set in teach mode
OFF
No power to validator
Using 4 Way DIL & Rotary Data Switches
To achieve a successful change to the configuration of the
validator the following procedure must be followed.
Switch
the power to the validator.
OFF
1.
Set the 4 way
switches to the configuration
DIL
2.
settings required. (See Product Configuration
Table)
Select the required data / channel position using
3.
the rotary data switch. (see product configuration
table)
Switch the validator power
. (The
ON
4.
start flashing).
Return the 4 way
teach switches back to
DIL
5.
Normal Operation Settings. (Switches 2,3 & 4 set
to all
or all
).
ON
OFF
The
will stop flashing and will stay
LED
ON
6.
will indicate a successful change and that the
validator is ready for normal operation.
NOTE:- If teach is entered by mistake, switch
power to the validator before moving the 4 way
switch positions else the mech. may learn something
unintentionally.
Product Configuration
Product Configuration Table
What Do You Want To Do?
Inhibit a coin or token channel
Enable a coin or token channel
Token group for channel 0
Token group for channel 1
Self teach a token for channel 0
Self teach a token for channel 1
Fraud Defence teach channel 0
Change overflow default exit route
Set the alarm
ON
Set the alarm
OFF
Selecting Machine Interface Types
Binary coded output
Parallel output
Auto configuration
w
E = Tight Window Limits. Channel F = Standard Window Limits
Teaching Token (
will
LED
Description
LED
for Code
Flashes
x 2
Validator timed out
Not enough sample tokens
x 3
inserted
. This
Incorrectly set rotary
x 4
switch position
Token thickness outside
x 5
acceptable limits
the
Token diameter outside
OFF
x 6
acceptable limits
DIL
x 7
Token material outside
acceptable limits
x 8
Normal Operation Settings
Set switches 2, 3 & 4
to ON or OFF
Channel
SW1
SW2
SW3
SW4
Position
0 - F
-
OFF
ON
OFF
0 - F
-
ON
OFF
OFF
0 - D
-
OFF
ON
ON
0 - D
-
ON
ON
OFF
s
-
OFF
ON
ON
E or F
s
-
ON
ON
OFF
E or F
E
-
ON
OFF
ON
0 - 7
-
OFF
OFF
ON
-
ON
-
-
-
-
OFF
-
-
-
C
-
D
-
OFF
OFF
ON
F
-
Assistance Codes)
LED
Reason/Action
No activity was registered
within 30 seconds
Ensure at least 10 tokens have
been inserted
Ensure that the rotary switch is
set to "F"
Check that there are no mixed
sample tokens
Teaching a New Token
The following procedure must be followed in order to teach
a new token into channel 1.
NOTE:- Rotary data switch position "E" is used to
program tight window token limits and 'F' standard
window token limits.
Switch
the power to the validator.
OFF
1.
Set the 4 way
teach switches 2, 3 & 4 to
DIL
2.
&
(channel 1) or OFF, ON & ON for
ON
OFF
(channel 0)
Set rotary data switch to position "F" standard
3.
window limit.
Switch
the power to the product.
ON
4.
(The
will start flashing).
LED
Insert 10 to 20 (minimum 10) of the desired
5.
tokens through the validator.
Return the 4 way
switches 2, 3 & 4 to
DIL
6.
Normal Operation settings.
(
will stop flashing and stay
to indicate
LED
ON
success).
If the
continues to flash
a number of
LED
OFF
times this indicates a failure to teach the new
token. See
Assistance Codes table for help
LED
and then restart procedure again.
Token is now programmed and ready to use.
7.
(New token information has been stored in coin
channel "1" which is rotary switch position "1").
Any previous taught token information in this
channel will be overwritten).
NOTE:- If token self teach is successful but token
taught is rejected i.e. gives 3 flashes of the
that channel "1" is enabled.
To enable the new token set the rotary data switch to
position "1" then refer to enabling coin or tokens
configuration procedure).
ON,
check
LED,

Advertisement

loading

This manual is also suitable for:

Cashflow 129